36 resultados para Brake Wear.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most interesting alternatives for replacement of hard chrome plating is tungsten carbide thermal spray coating applied by the high velocity oxy-fuel (HVOF) process which presents a safer, cleaner and less expensive alternative to chromium plating. The objective of this research is to compare the influence of the tungsten carbide-17cobalt (WC- 17Co) coating applied by high velocity oxy fuel (HVOF) process with that of hard-chromium electroplating on the fatigue strength and abrasive wear of AISI 4340 steel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on previously prepared notched plates made of resin. Vickers microhardness was measured in plates and files, before and after surface treatment and the surface chemical composition of the instruments was determined by X-rays photoelectron spectroscopy. Results The hardness values found for the treated Nitinol files were significantly lower than the hardness values measured before the implantation process. The comparison of commercially available instruments shows that the wear resistance of the stainless steel file is higher than the resistance of the Nitinol. Conclusions The results found led to the conclusion that the surface treatment significantly increased the Nitinol files wear resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a method of identifying morphological attributes that classify wear particles in relation to the wear process from which they originate and permit the automatic identification without human expertise. The method is based on the use of Multi Layer Perceptron (MLP) for analysis of specific types of microscopic wear particles. The classification of the wear particles was performed according to their morphological attributes of size and aspect ratio, among others. (C) 2010 Journal of Mechanical Engineering. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal spray WC-based coatings are widely used in the aircraft industry mainly for their resistance to wear, reworking and rebuilding operations and repair of worn components on landing gear, hydraulic cylinders, actuators, propeller hub assemblies, gas turbine engines, and so on. The aircraft industry is also trying to use thermal spray technology to replace electroplating coatings such as hard chromium. In the present work, WC-Co coatings were built up on an AA 7050 aluminum alloy using high velocity oxygen fuel (HVOF) technology and a liquid nitrogen cooling prototype system. The influence of the spray parameters (standard conditions, W19S, increasing the oxygen flux, W19H, and also increasing the carrier gas flux, W19F) on corrosion, friction, and abrasive wear resistance were also studied. The coatings were characterized using optical (OM) and scanning electron (SEM) microscopy, and X-ray diffraction (XRD). The friction and abrasive wear resistance of the coatings were studied using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (E(oc)) measurements and electrochemical impedance spectroscopy (EIS). Differences among coated samples were mainly related to the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for the coatings studied, and all of them showed a wear rate around 10 times lower than that of the aluminum alloy. The results of mass loss and wear rate were interpreted considering different mechanisms. Comparing the different spray parameters, the oxygen flux (higher flame temperature) produced the sample which showed the highest corrosion resistance in aerated and unstirred 3.5% NaCl solution. Aluminum ions were detected on the surface almost immediately after the immersion of samples W19S and W19F in chloride solution, showing that the electrolyte reached the substrate and galvanic corrosion probably occurred. For sample W19H, aluminum ions were not detected even after 120 min of immersion in NaCl solution. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the relationship between Candida and denture wear during the night. Twenty-four edentulous volunteers were randomly divided into two groups. Group I (GI, n = 11) was composed of volunteers who wore their complete dentures day and night and Group H (GII, n = 13) was composed of volunteers who wore their complete dentures only during the day. Three examination periods were performed for both groups. In GI, the first examination (A) was carried out after overnight denture wearing. Subsequent examinations were conducted after one (B) and seven nights (C) without denture use during sleep. In GII, the first (A) was done without previous use during sleep, and the following were carried out after one (B) and seven nights (C) of overnight denture wearing. Total un-stimulated saliva was collected in a sterile container and cultured in duplicate inside Petri dishes. The values of colony forming units (CFU mL(-1) +/- s.d.) were obtained: GI A - 10.1 x 10(3) +/- 1.2 x 10(4), B - 2.0 x 10(3) +/- 2.6 x 10(3), and C - 2.6 x 10(3) +/- 5.9 x 10(3) and GII: A - 0.4 x 10(3) +/- 0.6 x 10(3), B - 9.4 x 10(3) +/- 17.7 x 10(3) and C - 6.3 x 10(3) +/- 15.3 x 10(3). The mean counts for Candida sp. were expressed as log (CFU + 1) mL(-1) and statistical significance of differences among groups was tested by ANOVA (alpha = 0.05). Multiple comparisons were performed according to Bonferroni test and indicated significant differences between A-B and A-C, but not between B and C for both groups. It was concluded that there is a significant relationship between continuous denture wear and Candida sp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. The accuracy of assessing maxillomandibular relationships for trial bases and dentures using phonetic and swallowing methods has not been compared to that observed with definitive prostheses. Thus, there is no evidence to prove whether measurements obtained through such methods remain the same after adaptation to dentures.Purpose. This study investigated changes in the closest speaking space, interocclusal rest space, and interocclusal distance during deglutition in edentulous patients during and after complete denture treatment.Material and methods. Eighteen edentulous subjects participated in this study and measurements were performed after 7 Intervals of time: (1) with occlusion rims and record bases following creation of the maxillomandibular relationship record, (2) with trial dentures, (3) at Insertion of definitive complete dentures, (4) 1 week, (5) 2 weeks, (6) 1 month, and (7) 3 months after insertion. Recordings of interocclusal distances were made with a mandibular kinesiograph. Closest speaking space was measured during the pronunciation of the word 'seis'. The distance between postural rest position and centric occlusion, or interocclusal rest space, was measured using a kinesiograph. Interocclusal distance during deglutition was tested by recording the closest mandibular position recorded during swallowing of 20 mL of water. Data were analyzed using repeated-measure ANOVA, followed by the Student-Newman-Keuls test (alpha=.05).Results. A significant (P <.01)reduction in the mean closest speaking space was found when it was evaluated using occlusion rims and record bases (4.6 mm) compared with other stages (3.0 to 3.4 mm). No significant differences were found in mean interocclusal rest space and interocclusal distance during deglutition among the time periods evaluated.Conclusions. The presence of occlusion rims can influence mandibular position during pronunciation of the /s/ sound. The arrangement of artificial teeth changes the closest speaking space. However, rest position and deglutition were not affected, either during denture fabrication or short-term use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses the development of a test bench and a methodology for the study of composite resin abrasive wear. To evaluate the operation of the test bench and to compare the proposed methodology with other existing ones, a study was made of the five composites most commonly used by dentists.The one-way ANOVA method and the Tukey test were used to statistically analyze the results by multiple comparisons of the groups of resins tested. Using the proposed methodology, these resins were classified in an increasing order of abrasive wear strength, as follows: Charisma (the lowest abrasive wear strength), Tetric, TPH, Herculite and Z-100 (the highest abrasive wear strength) (P < 0.05). In comparison to other methodologies, the results of the proposed methodology presented the lowest coefficient of variation. (C) 2002 Elsevier B.V. B.V. All rights reserved.