11 resultados para American National Red Cross.
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.
Resumo:
Introduction: The aim of this study was to evaluate the pH, calcium ion release, setting time, and solubility of white mineral trioxide aggregate (WMTA) and white Portland cement (WPC) combined with the following radiopacifying agents: bismuth oxide (BO), calcium tungstate (CT), and zirconium oxide (ZO). Methods: Fifty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH and calcium release (atomic absorption spectrophotometry) at 3, 24, 72, and 168 hours. For evaluation of setting time, each material was analyzed according to the American Society for Testing and Materials guidelines 266/08. The solubility test was performed according to American National Standards Institute/American Dental Association specification no. 57/2000. Solubility, setting time, and pH values were compared by using analysis of variance and Tukey test, and the values of calcium release were compared by the Kruskal-Wallis and Miller tests. The significance level was set at 5%. Results: The pH and calcium release were higher at 3 and 24 hours. WPC was the material with the higher values for both properties. WMTA had the greatest solubility among all materials (P <.05). All radiopacifiers increased the setting time of WPC, and WMTA had the shortest setting time among all materials (P < .05). Conclusions: All materials released calcium ions. Except for WPC/CT at 168 hours, all materials promoted an alkaline pH. On the basis of the obtained results, ZO and CT can be considered as potential radiopacifying agents to be used in combination with Portland cement. Copyright © 2012 American Association of Endodontists.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective. The general aim of this article is to describe the state-of-the-art of biocompatibility testing for dental materials, and present new strategies for improving operative dentistry techniques and the biocompatibility of dental materials as they relate to their interaction with the dentin-pulp complex.Methods. The literature was reviewed focusing on articles related to biocompatibilty testing, the dentin-pulp complex and new strategies and materials for operative dentistry. For this purpose, the PubMed database as well as 118 articles published in English from 1939 to 2014 were searched. Data concerning types of biological tests and standardization of in vitro and in vivo protocols employed to evaluate the cytotoxicity and biocompatibility of dental materials were also searched from the US Food and Drug Administration (FDA), International Standards Organization (ISO) and American National Standards Institute (ANSI).Results. While there is an ongoing search for feasible strategies in the molecular approach to direct the repair or regeneration of structures that form the oral tissues, it is necessary for professionals to master the clinical therapies available at present. In turn, these techniques must be applied based on knowledge of the morphological and physiological characteristics of the tissues involved, as well as the physical, mechanical and biologic properties of the biomaterials recommended for each specific situation. Thus, particularly within modern esthetic restorative dentistry, the use of minimally invasive operative techniques associated with the use of dental materials with excellent properties and scientifically proved by means of clinical and laboratory studies must be a routine for dentists. This professional and responsible attitude will certainly result in greater possibility of achieving clinical success, benefiting patients and dentists themselves.Signcance. This article provides a general and critical view of the relations that permeate the interaction between dental materials and the dentin-pulp complex, and establish real possibilities and strategies that favor biocompatibility of the present and new products used in Dentistry, which will certainly benefit clinicians and their patients. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.
Resumo:
We describe the isolation and characterization of ten microsatellite loci from the red-winged tinamou (Rhynchotus rufescens) and also evaluated the cross-amplification of these loci and other ten loci previously developed for the great tinamou (Tinamus major) in other tinamous. Genetic variability was assessed using 24 individuals. Six loci were polymorphic with moderate to high number of alleles per locus (2-12 alleles) and showed expected heterozygosity (HE) ranging from 0.267 to 0.860. All loci conformed to the Hardy-Weinberg expectation and linkage disequilibrium was not significant for any pair of loci. This battery of polymorphic loci showed high paternity exclusion probability (0.986) and low genetic identity probability (4.95 x 10(-5)), proving to be helpful for parentage tests and population analyses in the red-winged tinamou. The cross-amplification was moderate where of the 160 locus/taxon combinations, 46 (28.75%) successfully amplified.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The ability of rattlesnake (Crotalus durissus terrificus) red blood cells to volume regulate in vitro has been investigated. Blood was drawn through a catheter inserted in the dorsal aorta and equilibrated to gas mixtures of different composition. Cells shrunken osmotically by increasing the extracellular osmolarity from approximate to 291 mosm l(-1) (n = 3) to approximate to 632 mosm l(-1) (calculated) only partially regulated their volume back towards the original volume either at pH 7.51 +/- 0.05 (mean +/- S.D., n = 5) or pH 7.20 +/- 0.06 (mean +/- S.D., n = 3), There was no improvement of the regulatory volume increase at low haemoglobin oxygen saturation. The limited volume restoration was inhibited by separate additions of amiloride (10(-4) M) or DIDS (10(-4) M) suggesting involvement of the Na+/H+ and Cl-/HCO3- exchangers. Cells that were swollen osmotically by an approximate to 30% dilution of the extracellular medium also exhibited a limited ability to recover their volume. Therefore, these cells show little ability to volume regulate when exposed to in vitro conditions that shrink or swell the cell. (C) 2000 Elsevier B.V. All rights reserved.
Resumo:
Diel variation in the abundance and size of Pleoticus muelleri in the Ubatuba region was investigated during 2000. During each season of the year, sampling was conducted during the day and at night at 8 depths, from 5 to 40 m. The estimated number of shrimp was 955 individuals, 272 collected during the day and 683 at night. There was a difference in the abundance of P. muelleri between day and night (χ², p=2.33E-40). The abundance during the day and at night differed by season with the exception of the spring (χ², p=0.06). The abundance during both periods also differed by depth, except at 15 and 30 m, where it was not significant (χ², p=0.84 and 0.06, respectively). The shrimp caught at night were generally smaller than those caught during the day (Kolmogorov-Smirnov, p<0.01). Pleoticus muelleri juveniles were found primarily at night. This tendency could have influenced the lower mean size for this period. The sediment type and the bottom temperature appear to influence the behavior of this species and consequently the catch rate during the periods analyzed.