14 resultados para 3D gloves for footwear design

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The expressive possibilities within the field of surface design come up with increasingly larger with the emergence of technologies that allow the construction of forms and structures of high complexity such as three-dimensional printing. Establishing a relationship between design and complex systems, this work seeks to address the significant interrelationship of new paradigms of science, designed from concepts such as chaos, complexity and self-organization along with the cyber and parametric design, assuming thus the consequent impact of these in the creation and construction of process surfaces. Starting from the investigation of the applicability of the aforementioned conceptual bases, will be exemplified prospects of surface, produced in the first instance through computer interfaces, assigning the emergence of new creative processes and technology. Furthermore, elucidating biomimetics and its importance in the design of the design as a means of inspiration in complex systems of nature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims at describing an educational system for teaching and learning robotic systems. Multimedia resources were used to construct a virtual laboratory where users are able to use functionalities of a virtual robotic arm, by moving and clicking the mouse without caring about the detailed internal robot operation. Moreover through the multimedia system the user can interact with a real robot arm. The engineering students are the target public of the developed system. With its contents and interactive capabilities, it has been used as a support to the traditional face-to-face classes on the subject of robotics.. In the paper it is first introduced the metaphor of Virtual Laboratory used in the system. Next, it is described the Graphical and Multimedia Environment approach: an interactive graphic user interface with a 3D environment for simulation. Design and implementation issues of the real-time interactive multimedia learning system, which supports the W3C SMIL standard for presenting the real-time multimedia teaching material, are described. Finally, some preliminary conclusions and possible future works from this research are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess 3D morphological variations and local and systemic biomarker profiles in subjects with a diagnosis of temporomandibular joint osteoarthritis (TMJ OA).Design: Twenty-eight patients with long-term TMJ OA (39.9 +/- 16 years), 12 patients at initial diagnosis of OA (47.4 +/- 16.1 years), and 12 healthy controls (41.8 +/- 12.2 years) were recruited. All patients were female and had cone beam CT scans taken. TMJ arthrocentesis and venipuncture were performed on 12 OA and 12 age-matched healthy controls. Serum and synovial fluid levels of 50 biomarkers of arthritic inflammation were quantified by protein microarrays. Shape Analysis MANCOVA tested statistical correlations between biomarker levels and variations in condylar morphology.Results: Compared with healthy controls, the OA average condyle was significantly smaller in all dimensions except its anterior surface, with areas indicative of bone resorption along the articular surface, particularly in the lateral pole. Synovial fluid levels of ANG, GDF15, TIMP-1, CXCL16, MMP-3 and MMP-7 were significantly correlated with bone apposition of the condylar anterior surface. Serum levels of ENA-78, MMP-3, PAI-1, VE-Cadherin, VEGF, GM-CSF, TGF beta b1, IFN gamma g, TNF alpha a, IL-1 alpha a, and IL-6 were significantly correlated with flattening of the lateral pole. Expression levels of ANG were significantly correlated with the articular morphology in healthy controls.Conclusions: Bone resorption at the articular surface, particularly at the lateral pole was statistically significant at initial diagnosis of TMJ OA. Synovial fluid levels of ANG, GDF15, TIMP-1, CXCL16, MMP-3 and MMP-7 were correlated with bone apposition. Serum levels of ENA-78, MMP-3, PAI-1, VE-Cadherin, VEGF, GM-CSF, TGF beta 1, IFN gamma, TNF alpha, IL-1 alpha, and IL-6 were correlated with bone resorption. Published by Elsevier Ltd on behalf of Osteoarthritis Research Society International.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cylinder head contains the combustion chamber for the air-fuel mixture and the intake and exhaust valves, the valve guide and the valve seat. The cylinder head also is a support for the camshaft and valve rocker. The holes where the spark plugs are connected are designed to fit the better place in the combustion chamber. The cylinder heads often are manufactured using materials such as aluminum and cast iron. The cooling fins located in the outside of the cylinder head are designed for a good heat transfer and therefore their dimensions and positioning are important. This work aims the calculation for a cylinder head to be installed in a 400 cc displacement, gasoline powered, four stroke, single cylinder engine. According to the displacement it will be analyzed the combustion chamber, the intake and exhaust valves, as well as the camshaft and rocker arms. This also a work to help to accomplish the design of a single cylinder engine, where the alternatives parts, cylinder block and crankcase are all already machined and assembled in this campus

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most of the hydraulic turbines that are running in the world are the Francis type, because they are able to fit a wide range of head and flow. We also can declare that most of the installed hydraulic energy up to this date is generated by this type of turbine. On the other hand, if we pay attention to mechanical details of a Francis turbine we will see that among the three most used types it is the one that presents the more complex design. And, the simplest one is the Pelton type, whereas the Kaplan is the one less utilized. This work aims to develop the hydrodynamic calculation of a Francis turbine as well as to obtain its assembly drawing and 3D modeling drawing. In this way all details must be shown therefore needing a complete knowledge about this issue. Both 2D and 3D drawings help much if one wants the machine to be running in its power house. It is well noted that most of the entities that design and manufacture the Francis turbines are not brazilian. In this way the more we study how to design this kind of machine the more is our contribution to our country in order to conquer technology and manufacture Francis turbines

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the geometry and design of prosthetic crown preparations on stress distribution in compression tests, using finite element analysis (FEA). Materials and Methods: Six combinations of 3D drawings of all-ceramic crowns (yttria-stabilized zirconia framework and porcelain veneer) were evaluated: F, flat preparation and simplified crown; FC, flat preparation and crown with contact point; FCM, flat preparation and modified crown; A, anatomical preparation and simplified anatomical crown framework; AC, anatomical preparation and crown with contact point; and ACM, anatomical preparation and modified crown. Bonded contact types at all interfaces with the mesh were assigned, and the material properties used were according to the literature. A 200 N vertical load was applied at the center of each model. The maximum principal stresses were quantitatively and qualitatively analyzed. Results: The highest values of tensile stress were observed at the interface between the ceramics in the region under the load application for the simplified models (F and A). Reductions in stress values were observed for the model with the anatomical preparation and modified infrastructure (ACM). The stress distribution in the flat models was similar to that of their respective anatomical models. Conclusions: The modified design of the zirconia coping reduces the stress concentration at the interface with the veneer ceramic, and the simplified preparation can exert a stress distribution similar to that of the anatomical preparation at and near the load point, when load is applied to the center of the crown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Design - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Art can be understood as a process in which knowledge is used to perform certain skills. From Latin ARS, technical means and / or ability, in Greece, there was the word art, but "Tekne", which originated from the word "technical." So art and technique are present in sculptures, paintings, shoes or ships. In this sense, designers, engineers and all professionals who use technology can be called artists. Considerations must be made regarding the level of energy embedded in the material from its production until its use, even considering recycling, sustainability and life cycle of materials. This study aimed to present the use of scanning technology and 3D virtual modeling and its application in prototyping with CNC (Computed Numerical Control) as a tool in current use cutting-edge courses in arts, design and engineering and their relations with sustainability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of computer-assisted technologies such as CAD - Computed Aided Design, CAM - Computed Aided Manufacturing, CAE - Computed Aided Engineering and CNC - Computed Numerical Control, are priorities in engineering and product designers. However, the dimensional measurement between the virtual and the real product design requires research, and dissemination procedures among its users. This work aims to use these technologies, through analysis and measurement of a CNC milling machine, designed and assembled in the university. Through the use of 3D scanning, and analyzing images of the machined samples, and its original virtual files, it was possible to compare the sizes of these samples in counterposition to the original virtual dimensions, we can state that the distortions between the real and virtual, are within acceptable limits for this type of equipment. As a secondary objective, this work seeks to disseminate and make more accessible the use of these technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)