60 resultados para 1113 Ophthalmology and Optometry

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. We quantified the main sequence of spontaneous blinks in normal subjects and Graves' disease patients with upper eyelid retraction using a nonlinear and two linear models, and examined the variability of the main sequence estimated with standard linear regression for 10-minute periods of time. Methods. A total of 20 normal subjects and 12 patients had their spontaneous blinking measured with the magnetic search coil technique when watching a video during one hour. The main sequence was estimated with a power-law function, and with standard and trough the origin linear regressions. Repeated measurements ANOVA was used to test the mean sequence stability of 10-minute bins measured with standard linear regression. Results. In 95% of the sample the correlation coefficients of the main sequence ranged from 0.60 to 0.94. Homoscedasticity of the peak velocity was not verified in 20% of the subjects and 25% of the patients. The power-law function provided the best main sequence fitting for subjects and patients. The mean sequence of 10-minute bins measured with standard linear regression did not differ from the one-hour period value. For the entire period of observation and the slope obtained by standard linear regression, the main sequence of the patients was reduced significantly compared to the normal subjects. Conclusions. Standard linear regression is a valid and stable approximation for estimating the main sequence of spontaneous blinking. However, the basic assumptions of the linear regression model should be examined on an individual basis. The maximum velocity of large blinks is slower in Graves' disease patients than in normal subjects. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Avaliou-se a resistência de genótipos de tomateiro selvagens [Lycopersicon pennellii (LA 716), L. hirsutum var. glabratum (PI 126449, PI 134417), L. hirsutum (PI 127826, PI 127827), L. peruvianum (CGO 6707), L. peruvianum var. dentatum (WYR 2020, LA 111), L. peruvianum var. glandulosum (LA 1113-1, LA 1113-2)] e comerciais [(L. esculentum) Gem Pride, Santa Clara, e híbridos Bruna VFN, Carmem, Fortaleza, Débora Plus VFN] ao ácaro rajado (Tetranychus urticae). O número médio de ovos, fases imaturas (larvas, protoninfas e deutoninfas) e adultos por folíolo foi contado; o índice de preferência para oviposição (IPO) foi calculado. O delineamento experimental foi blocos ao acaso, com 6 repetições. Os genótipos LA 716, PI 126449, PI 134417, PI 127827, PI 127826 e Gem Pride apresentaram não-preferência para oviposição do ácaro rajado, sendo deterrentes quanto à classificação do IPO, enquanto os genótipos LA 111, WYR 2020, LA 1113-2 e LA1113-1 foram os mais preferidos para a oviposição e foram considerados como estimulantes pelo IPO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relatou-se o efeito do transplante de glândulas salivares menores (TGSM) em cães portadores de ceratoconjuntivite seca (CCS) e estudaram-se os efeitos da secreção dessas glândulas usadas como alternativa de lubrificação ocular. A aplicação da técnica foi satisfatória, uma vez que resultou em melhora no quadro clínico oftalmológico sem que houvesse mínimas intercorrências pós-operatórias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare knowledge of medical students about the cornea donation process among those who already studied Ophthalmology and the others. Methods: A questionnaire containing data as: age, sex, graduation year, and 10 multiple-choice questions about the subject was applied to medical students from the interior of São Paulo state, Brazil. The questions were: age for donation, contraindication for transplants, the time limit to remove the cornea, among others. The knowledge regarding cornea donation was compared between the two groups: students who already studied Ophthalmology (Group A) and the others (Group B). Results: The study group was composed of 402 students, of whom 140 were of group A and 262 of group B. Knowledge between the two groups was different, but not statistically significant (p=0.8328). Conclusion: Knowledge about the cornea donation process among the interviewed seemed to be insufficient, even those who had studied Ophthalmology. Information and education about transplants in Medical Schools should be improved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. Methods: A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. Results: The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). Conclusion: The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. © SLACK Incorporated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work proposes a method for dioptric power mapping of progressive lenses through dual wavelength, low-coherence digital speckle pattern interferometry. Lens characterization finds several applications and is extremely useful in the fields of ophthalmology and astronomy, among others. The optical setup employs two red diode lasers which are conveniently aligned and tuned in order to generate a synthetic wavelength. The resulting speckle image formed onto a diffusive glass plate positioned behind the test lens appears covered of contour interference fringes describing the deformation on the light wavefront due to the analyzed lens. By employing phase stepping and phase unwrapping methods the wavefront phase was retrieved and then expressed in terms of a Zernike series. From this series, expressions for the dioptric power and astigmatic power were derived as a function of the x- and y-coordinates of the lens aperture. One spherical and two progressive lenses were measured. The experimental results presented a good agreement with those obtained through a commercial lensometer, showing the potentialities of the method. © 2013 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective The aim of the present study was to evaluate the effects of nitrous oxide on TOP and pupillary diameter (PD) of dogs anesthetized with varying desflurane concentrations.Animals studied Twenty adult Mongrel dogs were used.Methods They were anesthetized with propofol (10 mg/kg, IV) and maintained with varying concentrations of desflurane (1.6, 1.4, and 1.2 MAC diluted in 100% oxygen (G1) or in 70% nitrous oxide and 30% oxygen (G2) (30 mL/kg/min). TOP was measured by applanation tonometry and horizontal PD was taken with a caliper adjacent to the cornea. Mean arterial pressure (MAP), heart rate (HR), respiratory rate (RR), and end-tidal CO, (etCO(2)) were also measured. All parameters were measured at TO, T30, T45, and T60 time points. One-way repeated measures ANOVA and the t-test were used to assess statistical differences (P < 0.05).Results T30, T45, and T60 TOP measures were Within normal limits for both groups and TOP did not differ between groups at any time. There was a significant decrease in PD in G I between TO and T30, T45 and T60, and also between T30 and T60. PD did not differ between groups. All vital parameters were within normal limits throughout anesthesia.Conclusions Administration of nitrous oxide with desflurane results in maintenance of normal TOP and prevents a decrease in horizontal PD during anesthesia. Therefore, this may be a suitable protocol in dogs undergoing intraocular surgeries that require mydriasis and maintenance of normal TOP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)