222 resultados para Guarani Aquifer
Resumo:
Successful application of shallow seismic reflection method is related directly to the ability of the ground to transmit high-frequency seismic energy from a seismic source. The dominant frequencies of reflection data are in the range of 50 to 100 Hz and depend on the surface materials and water table. A spread of geophones send the siemsic signal to be recorded on a 12, 24 or 48 channel portable seismograph, using a single high-frequency geophone per channel. Although it is possible to find seismographs with display and processing unities, it is also possible to transfer digitalized data to a personal computer to be processed and interpreted by using specific programs. Some results of two recent field studies to specify the underground structure in the tidal flats area of Baie St. Paul (Quebec-Canada) and in glacial terrains, in the Waterloo (Ontario-Canada) region. -from English summary
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study was conducted in Adamantina, region of Alta Paulista, São Paulo State, Brazil, from 1989 to 1993. Yield of Apoatã coffee (Coffea canephora Pierre ex Froehner) was evaluated during four years of intercropping with five plant species: IAC 20 - cotton (Gossypium hirsutum L.); cv. Tatu - peanut (Arachis hypogaea L.); IAC 165 - rice (Oryza sativa L.); cv. Guarani - castor bean (Ricinus communis L.) and IAC 100-B - corn (Zea mays L.). The crops were seeded 50 cm apart from coffee canopy. The treatments were arranged in randomized complete block design with five replications. Yield was significantly decreased when coffee was intercropped with castor bean, corn, cotton and peanut, but height and diameter of orthotropic branches were not affected. Linear correlation analysis showed that coffee yield was inversely correlated with the dry biomass of the intercrops.
Pollution by hexachlorobenzene and pentachlorophenol in the coastal plain of São Paulo state, Brazil
Resumo:
Organochlorine compounds were dumped by chemical industries during the 1970s in many areas of the coastal plain of São Paulo state in Brazil. These dumps, located on hillsides and in valleys, in both rural and urban environments, are responsible for soil and water pollution. The objective of this work was to determine how the pollutants have spread in an area occupied by a spodosol-type soil mantle. The study combines soil morphological observations with soil and water analysis of hexachlorobenzene (HCB) and pentachlorophenol (PCP) in soil toposequences. The results indicate that the highest pollutant concentrations are observed near the dump site and that the compounds contamination is increasing. A map integrating topography and chemical concentrations was created to visualize the spatial distribution of HCB levels in the landscape. Physical and chemical analyses were performed to measure HCB and PCP levels in the soil. Soil water appears to act as a vector of HCB, probably through complexation with and dispersal of dissolved organic matter. The persistence of HCB at the studied site is most likely due to the low pH values in combination with a high content of organic matter. HCB was consistently found in higher concentrations than PCP. It is plausible that the cause of this difference is that PCP is degraded more easily under sunlight than HCB and that degradation of PCP under acid conditions leads to the formation of HCB. © 2003 Published by Elsevier B.V.
Resumo:
A site investigation program was carried out to detect salt-water intrusions in a shallow sedimentary aquifer based on electrical resistivity measurements. The site is located close to Paranaguá harbor, in the Paraná State, Brasil. At this site, high chloride concentration contaminated shallow water wells used to supply water for local industries. The site investigation program included a fieldwork, dipole-dipole electrical profiling, resistivity piezocone tests, physical-chemical analysis of sampled water and interpretation of borehole logs. The resistivity piezocone tests provided two simultaneous information; the soil stratigraphy at a very detailed level and a quasi-continuous resistivity profile. Both information adequately complemented dipole-dipole electrical profiling test data. The integration of all test data allowed identifying the contaminated areas as well as guided the location of new water wells to be installed in this area.
Resumo:
Resistivity (DC) method using vertical electrical soundings (Schlumberger array) are conducted In the vicinity of Canoas/RS, applied to environmental studies with the objective of Investigating groundwater conditions, The present paper shows a geoelectrlcal Identification of the lithology and an estimate of the relationship between the resistivity and Dar Zarrouk parameters (transverse unit resistance and longitudinal unit conductance) with the properties such as aquifer transmlssivlty and protection of ground water resources, In the saturated sediments, resistivity values defined the following sequence: clay layers (resistivity < 40 ohm-m) and sand layers (resistivity > 40 ohm-m), Two sand layers were identified; one corresponding to the unconfined aquifer and another to the confined aquifer between two clay layers, In the map of the transverse unit resistance of the unconfined aquifer, the tendencies of high values can be associated with the zones of high transmissivity; hence, these zones are suggested for the installation of monitoring wells, The map of longitudinal conductance Illustrates the Impermeability of the confining clay layer, Values of S > 1.0 siemens would indicate zones in which the confined aquifer would be protected; In comparison, values of S < 1.0 siemens would indicate zones of probable risks of contamination. © 2006 Sociedade Brasileira de Geofísica.
Resumo:
This paper presents two case histories from Brazil where geophysical and resistivity piezocone tests were carried out to detect contamination. At the first one, the site investigation program was carried out to detect salt-water intrusions in a superficial sedimentary aquifer, at the Paranaguá harbor, in Paraná State. The second case history is a sanitary landfill from Bauru City, São Paulo State. In both sites, superficial geophysical tests were interpreted to detect and delineate the shape of contamination plume, helping to locate the resistivity piezocone tests. It was found that the interpretation of resistivity piezocone tests is straightforward to assess salt-water intrusion in sedimentary sands. For tropical soils, this technique presented some limitations since the groundwater table sometimes is deeper than the layer penetratable to the cone. Moreover, the genesis of those soils affects soil behavior and soil and water sampling is required to support interpretation.
Resumo:
It was objectified to quantify the initial growth of varieties of castor bean with boron fertilization. Had been tested to cultivate they AL-Guarani, Mirante 10 and Nordestina to the doses of 0; 0.25; 0.50; 0.75 and 1.0 mg kg -1 of B in controlled environment of greenhouse in the Sector of Cafeicultura of the Department of Agriculture of the UFLA. The characteristics valued were: height of plants, length of roots, leaf number, diameter of stem, mass of dry substance (MS) of leafs, of stem, the root and total. To cultivate Mirante 10 it was the one that got minor growth of the system of root. For leaf number to cultivate AL-Guarani it was superior to Mirante 10 and Nordestina. Also to cultivate better AL-Guarani if it detached how much to the production of total mass of MS, while to cultivate Mirante 10 produced more mass of MS than Nordestina.
Resumo:
The petrographic and geochemical characterization of flood basalts of Serra Geral Formation are here presented. The investigated areas are situated in four different regions of São Paulo state: Jaú, Ribeirão Preto, Franca and Fernandópolis. They represent almost the total area of outcrops of basalts in the São Paulo State. The petrographical data reveals that these rocks are constituted mainly by plagioclase (30-40%), pyroxenes, augite and pigeonita (20-30%) and magnetite (5-15%), and show a intergranular texture and its varieties intersertal, hialophitic and pilotaxitic. The geochemical data show a basic and tholeiitic affinity of the studied basalts, with high-Ti content (TiO2 > 1.8%), typical of the northern region of Paraná Basin. Three different magma-types were recognized: Paranapanema, Urubici and Pitanga. The first magma-type is concentrated in the Fernandópolis region, the second in the Franca region, and the Pitanga occurs in the Ribeirão Preto and Jaú regions. The distribution patterns of these magma-types and the detailed study of geochemical data showed that they are, probably, generated by a melting of a continental lithospheric mantle.
Resumo:
The Ji-Paraná city (RO) it doesn't possess public system of collection and treatment of sewers, being the waters residuárias produced by the local population thrown at sewages. Traditionally, many inhabitants use wells amazon extracted underground water or tubular shallow in the urban zone. The study accomplished in the Nova Brasília neighborhood for Silva (2009) revealed that the local aquifer is strongly contaminated for nitrate, originated of the decomposition of the organic matter deposited at the sewages local maidservants. With the objective of detecting areas with high concentrations originating from organic compositions of septic sewages, geophysical risings were accomplished, later related with analyses physical-chemistries in samples of groundwaters obtained in several wells installed in the Nova Brasília neighborhood, besides of soil samples descriptions in zone not saturated obtained in wells. The results obtained by the geophysical rehearsals they reveal that the polluting feather not migrates through the zone saturated, arriving with relative easiness to the aquifer, reaching in some points, superior depth to 34 m reached by the geoelectrical profiling.
Resumo:
The equivalent uranium (eU) activity concentration was analysed in selected granite samples at several sites in Porto Alegre, Southern Brazil, to obtain information on the radon (222Rn) generation by the aquifer rock matrices. Radon analyses of ground water and soil samples were also performed. Several samples exhibited a dissolved 222Rn activity concentration exceeding the World Health Organization maximum limit of 100 Bq l-1. The dissolved radon content in ground waters from the Fractured Precambrian Aquifer System exhibited a direct significant correlation with the eU in the rock matrices, which is a typical result of water-rock interactions. Variation in the soil's porosity was confirmed as an important factor for 222Rn release, as expected, due to its gaseous nature. Thus, although the calcic-alkaline to alkaline Precambrian granitoid rocks of the study area are important reservoirs for underground resources, they can release high amounts of radon gas into the liquid phase. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
The disposal of solid waste can create environmental problems, in addition to the potential risk of instability even in planned geotechnical works, such as provisions in stacks or high ends of the landfill, because they represent mere adjustments in civil engineering works. The Leme city, SP, generates about 35 t/day of municipal waste, that are deposited in a landfill located in the Barro Preto neighborhood. This work conducted a geophysical survey, based on geotechnical instability evidence in area, for analysis of the conditioners that cause on the sides leachate resurgence landfill and its relationship to mass movements and ravines installation in cover soil, with consequent waste exposure. The results indicate horizons of low resistivity connected with resurgence points generated by the organic matter decomposition contained in the waste. Such horizons result in leachate concentration in some places, which, in turn, may lead to loss of cohesion of the materials constituting the residues mass. The results are areas with mass flow by rotational movements, which, together with the surface flow of rainwater, evolves into ravines and exposed residues, preferably at the resurgence point. The leachate flow on the surface affects areas beyond the limits at landfill with direct impact on local agriculture and risk to pedestrians using the highway bordered by the landfill beyond the soil and the local aquifer.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)