149 resultados para Chest


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Genética e Melhoramento Animal - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was evaluate the effects of immunocastration on body weight gain, carcass characteristics and meat quality of Nellore beef cattle. Eighty Nellore beef cattle, with initial body weight of 357 +/- 8.63 kg, were placed in feedlots and distributed in two treatments (40 animals per treatments) as follow: one - non-vaccinated bulls and two - immunocastrated bulls (Bopriva (R), Pfizer Animal Health). The animals placed on treatment two were vaccinated in two doses, first application 30 days before they arrive on the feedlots and second on the day they arrive on feedlots. After 67 days of experimental period, was calculated the daily gain of live weight in kg/day of the 80 animals and selected 20 animals from each treatment for the slaughter and carcass evaluations, and ten from each group for the meat analyzes. The data were submitted to analysis of variance. Immunocastrated animals showed lower daily weight gain, hot carcass weight, carcass yield, pH, leg thickness, muscle depth, loin muscle area, carcass muscle percentage, shear force and moisture. However, this animals had higher concentration of lactate and cortisol blood, chest depth, fat thickness, finishing degree, a *, b * and c*, liquid loss in thawing process, myofibrillar fragmentation index and ether extract of meat when compared to non-vaccinated bulss. The immunocastration (Bopriva (R)) is an alternative for improving the quality of meat by the higher fat deposition and by the reduction of the shear force of the meat when compared to non-vaccinated bulls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This experimental study aimed the evaluation of the use of anthropomorphic phantoms in the analysis of the influence of the acquisition parameters in the contrast of radiographic images. The analyzed factors were the variation of the peak kilovoltage (kVp) and the product of the filament circuit by the time of exposition (mAs). The influence of these factors was verified for different anthropomorphic phantoms: foot, knee and chest. The image contrast behavior with the simulators was compared to values obtained with the use of an aluminum ladder being the behavior of this reference for analysis and discussion. To assure the reproducibility of images, quality control tests were made and evaluation of procedure conditions before the experiments. The results obtained are shown in a scale of images where it was possible to evaluate the impact in the darkness of images. Regions with different compositions were analyzed which were different in image, this way the values of optical density and contrast are represented as charts and graphics. We conclude that the use of anthropomorphic phantoms in the evaluation of the influence of tension of the tube and time of exposition in the contrast of the radiographic images is not indicated for a quantitative analysis through optical density, once they present incompatible results with the data as reference as the aluminum ladder even so these simulators present a great property in qualitative analysis regarding the differentiation of structures and subjective evaluations

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is imortant to be able to evaluate the cardiact size . In 1995, was proposed by Buchanan and Bücheler a new way to measure the dimensions of the cardiac silhouette. This study aims to gather several studies of the cardiac dimensions by VHS method in the right lateral recumbency of of different breeds of dogs in a single work, facilitating the assess to information. Deep chest breeds have a smaller mean VHS value than the barrel chest breeds, showing that there is a variation of the VHS values acoording to the thoracic conformation of each breed, which indicates that there is a need to recognize the specific VHS values according to the breed standard to not to interpret the cardiac measurement in a wrong way through not compatible reference values for the animal. There is the individual variation that should be taken into accont at the time of measurement. The VHS is a helper method to a radiographic evaluation of the heart, and the ultrasonography remains the gold standard for the evaluation of the cardiac chambers and other changes of the heart

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endoscopy of the gastrointestinal tract is a specialized minimally invasive diagnostic method and with both diagnostic and therapeutic possibilities. It is divided into two major groups, the rigid and flexible endoscopy. The first most widely used for visualization of body cavities that do not have a light, like the chest, for example, and the second for those with light as the gastrointestinal tract. In Brazil there are few professionals, veterinary hospitals or clinics that offer this type of service. Thus, endoscopy is an area of expertise of the veterinarian who is in huge expansion and has shown great applicability with excellent results in both clinical medicine and surgical small animals

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gastric dilatation- volvulus (GDV) is an acute and potentially lethal disease, characterized by increased size of the stomach associated with mesenteric rotation on its axis, which affects mainly large breed dogs and giants with deep and narrow chest. The diagnosis is made from the history, physical examination, clinical signs and radiographic evaluation. It is an emergency that requires immediate therapy and consists on protocols to treat shock, gastric decompression, surgical repositioning of the stomach, gastropexy and intensive post-operative care. Despite the significant progress in the elucidation of pathophysiological events, risk factors and treatment, there was almost no progress in determining the root causes of this disease. A significant advance was recently described in the literature on this topic is the technique of gastropexy laparoscopy. Instruct the owners of the high risk breeds is extremely important to avoid situations in which the severity of the illness make the surgical treatment impracticable and the animal’s condition irreversible

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The perceived exertion has been used for the intensity control and exercise prescription. Among the various scales that estimate the perceived exertion, the Borg’s RPE scale is one of the best known. However, for populations with low levels of schooling or with visual difficulties such as the elderly, the application of these scales becomes more difficult. In previous studies, a color scale of perceived exertion was developed to aim for assistance in application of the scale and interpretation of perceived exertion. This scale showed high correlation with the Borg’s scale and proved to be valid to estimate the perceived exertion. Thereby, the aim of this study was to assess the validity of the color scale of perceived exertion to measure the perceived exertion in adult women of different ages. Participated in the study 12 young adult women with age of 21,7 ± 1,5 years old, and 10 elderly women with age of 60,3 ± 3,5 years old. The participants were submitted to an incremental exercise of treadmill walking with stages of 2 minutes duration. The inicial load was 5,5 km/h and inclination of 6% for young women and 2% for elderly women, both with 2% increments at each stage completed, without changing the speed. Heart rate and oxygen comsuption responses were determined at the 30 finals seconds of each stage. At the 60 finals seconds of each stage participants indicated the perceived exertion for the overall body, for the legs and for the chest, primarily in the color scale and following in the tradicional Borg’s scale. The analysis of variance for repeated measures was used to assess the effect of different loads on the perceived exertion and physiological responses. The correlations betwen physiological variables, color scale and Borg’s scale were analyzed in group and individually. In all analysis the significance...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Animal - FMVA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Pectus excavatum is characterized by a depression of the anterior chest wall (sternum and lower costal cartilages) and is the most frequently occurring chest wall deformity. The prevalence ranges from 6.28 to 12 cases per 1000 around the world. Generally pectus excavatum is present at birth or is identified after a few weeks or months; however, sometimes it becomes evident only at puberty. The consequence of the condition on a individual's life is variable, some live a normal life and others have physical and psychological symptoms such as: precordial pain after exercises; impairments of pulmonary and cardiac function; shyness and social isolation. For many years, sub-perichondrial resection of the costal cartilages, with or without transverse cuneiform osteotomy of the sternum and placement of a substernal support, called conventional surgery, was the most accepted option for surgical repair of these patients. From 1997 a new surgical repair called, minimally invasive surgery, became available. This less invasive surgical option consists of the retrosternal placement of a curved metal bar, without resections of the costal cartilages or sternum osteotomy, and is performed by videothoracoscopy. However, many aspects that relate to the benefits and harms of both techniques have not been defined. Objectives: To evaluate the effectiveness and safety of the conventional surgery compared with minimally invasive surgery for treating people with pectus excavatum. Search methods: With the aim of increasing the sensitivity of the search strategy we used only terms related to the individual's condition (pectus excavatum); terms related to the interventions, outcomes and types of studies were not included. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), PubMed, Embase, LILACS, and ICTPR. Additionally we searched yet reference lists of articles and conference proceedings. All searches were done without language restriction. Date of the most recent searches: 14 January 2014. Selection criteria: We considered randomized or quasi-randomized controlled trials that compared traditional surgery with minimally invasive surgery for treating pectus excavatum. Data collection and analysis: Two review authors independently assessed the eligibility of the trials identified and agreed trial eligibility after a consensus meeting. The authors also assessed the risk of bias of the eligible trials. Main results: Initially we located 4111 trials from the electronic searches and two further trials from other resources. All trials were added into reference management software and the duplicates were excluded, leaving 2517 studies. The titles and abstracts of these 2517 studies were independently analyzed by two authors and finally eight trials were selected for full text analysis, after which they were all excluded, as they did not fulfil the inclusion criteria. Authors' conclusions: There is no evidence from randomized controlled trials to conclude what is the best surgical option to treat people with pectus excavatum.