144 resultados para Abrupt edges removal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correction of diastemas in the anterior region with composite resin is considered to be practical and conservative. Harmony between the restorative material and the periodontium is necessary to achieve satisfactory functional and esthetic results. Whenever excessive gingiva occurs in the interproximal region, removal is necessary to avoid excessively contoured restorations. A predictable technique is described to conservatively remove interproximal tissue in situations in which crown lengthening is required to treat bilateral diastemas. A surgical template based on the diagnostically waxed cast was produced to serve as a reference during periodontal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC).Materials and Methods: Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw. RT values were measured and registered. Data (in Newton centimeter) were analyzed with analysis of variance and Dunnet test (alpha = 0.05).Results: RT values were significantly affected by MC (P = 0.001) and the interaction between DLC coating and MC (P = 0.038). SCy and ACy showed the lowest RT values, statistically different from the control. The abutment coated groups had no statistical difference compared with the control. Scanning electron microscopy analysis showed DLC film with a thickness of 3 mm uniformly coating the hexagonal abutment.Conclusion: DLC film deposited on the abutment can be used as an alternative procedure to reduce abutment screw loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecological processes in tropical forests are being affected at unprecedented rates by human activities. Yet, the continuity of ecological functions like seed dispersal is crucial for forest regeneration. It thus becomes increasingly urgent to be able to rapidly assess the health status of these processes in order to take appropriate management measures. We tested a method to rapidly evaluate seed removal rates on two animal-dispersed tree species, Virola kwatae and V.michelii (Myristicaceae), at three sites in French Guiana with increasing levels of anthropogenic disturbance. We counted fallen fruits, fruit valves, and seeds of each focal fruiting tree in a single 1m2 quadrat, and calculated two indices: the proportion of seeds removed and the proportion of fruits opened by mammals. They both provide an indirect and rapid assessment of frugivore activity. Our results showed a significant decrease in the proportion of removed seeds (16%) and fruits opened (19%) at the most impacted site in comparison with the other two sites (79% for seeds, 60% and 35% for fruits). This testifies to an increased impoverishment of the primate and toucan communities at the disturbed sites. This standardized protocol provides fast information about the health status of the community of seed dispersers and predators and of their seed removal services. It is time- and cost-effective and is not species-specific, allowing comparisons among sites or over time. We suggest using it with the pantropical Myristicaceae and any other capsule-producing family to rapidly assess the health status of seed removal processes across the tropics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, use was made of tucumã cake, in natura (TCN) and thermally treated (TCT), as potential alternative adsorbents for the adsorption of cationic and anionic dyes. The effects of the parameters: contact time, adsorbent: adsorbate mass ratio, and initial concentration of dye were analyzed. The adsorption isotherms were established from optimized adsorption parameters. The best conditions for adsorption were: equilibrium time of 7 h, concentration of 25 mg L 1 and ratio of 1:200 for the methylene blue dye; and pH 6.5, concentration of 25 mg L 1 and ratio of 1:200 for the congo red dye. The adsorption process was best represented by the Dubinin–Radushkevich and Sips isotherms. The kinetics of adsorption of the dyes were best described by the pseudo-second-order kinetic and Elovich models. TCT showed the best maximum adsorption capacity (Qm) for the methylene blue dye (63.92 mg g 1 ).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effectiveness of ProTaper universal retreatment system in the removal of root canal filling material with thermomechanical compaction, in comparison to manualmechanical technique, associated with orange oil or eucalyptol. Materials and methods: Forty extracted lower incisors were filled with thermomechanical compaction technique. After 3 years, the root canal filling was removed by: G1 - manualmechanical technique with orange oil; G2 - manual-mechanical technique with eucalyptol; G3 - ProTaper universal retreatment system with orange oil and G4 - ProTaper universal retreatment system with eucalyptol. In sequence, all root canals were instrumented to F5 instrument. The teeth were longitudinally grooved, images of buccal half were obtained in stereomicroscope and covered area by root canal filling material was measured using image tool software, in cervical, middle and apical radicular thirds. The results were subjected ANOVA and Tukey test (p = 0.05). Results: In all thirds, the manual-mechanical technique showed lower presence of root canal filling material on root canal dentin in comparison to ProTaper retreatment universal system, regardless of organic solvent used (p < 0.05). There is no difference between organic solvents in removal root canal filling material (p > 0.05). Conclusion: The ProTaper universal retreatment system showed lower effectiveness in removal root canal filling material than manual-mechanical technique, regardless of organic solvents (orange oil or eucalyptol oil) used. Clinical significance: Recently rotary instruments have been proposed to removal of root canal filling material. However, there are no studies evaluating its effectiveness in removal root canal filling material in association with orange oil or eucalyptol oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The removal of resin debris and/or resin cement from the enamel surface without causing iatrogenic is the main objective when removing the orthodontic brackets. Some factors such as the time required for removal, damage to the tooth structure, are essential factors for the clinician at the time of removal. Various techniques are used for the removal of orthodontic brackets after the treatment; it is known that the use of clinical procedures such as the use of diamond burs and some pliers removers can damage the structure of the enamel, often depending on the bond strength that should be taken into consideration at the time of removal. This literature review aims to gather the most relevant studies that can clarify the clinical technique, which may be more suitable for removal of the brackets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The grinding operation gives workpieces their final finish, minimizing surface roughness through the interaction between the abrasive grains of a tool (grinding wheel) and the workpiece. However, excessive grinding wheel wear due to friction renders the tool unsuitable for further use, thus requiring the dressing operation to remove and/or sharpen the cutting edges of the worn grains to render them reusable. The purpose of this study was to monitor the dressing operation using the acoustic emission (AE) signal and statistics derived from this signal, classifying the grinding wheel as sharp or dull by means of artificial neural networks. An aluminum oxide wheel installed on a surface grinding machine, a signal acquisition system, and a single-point dresser were used in the experiments. Tests were performed varying overlap ratios and dressing depths. The root mean square values and two additional statistics were calculated based on the raw AE data. A multilayer perceptron neural network was used with the Levenberg-Marquardt learning algorithm, whose inputs were the aforementioned statistics. The results indicate that this method was successful in classifying the conditions of the grinding wheel in the dressing process, identifying the tool as "sharp''(with cutting capacity) or "dull''(with loss of cutting capacity), thus reducing the time and cost of the operation and minimizing excessive removal of abrasive material from the grinding wheel.