177 resultados para temperature influence
Resumo:
Intense and broad visible photoluminescent (PL) band was observed at room temperature in disordered Pb(Zr(0.53)Ti(0.47))O(3) powders. Structural order-disorder was evaluated by different methods. XANES results pointed to the presence of different coordination modes of disordered Ti powders, and in the ordered sample the local structure around titanium atoms is characteristic of the structurally ordered PZT with only TiO(6) units. Only samples containing simultaneous structural order and disorder in their network present the intense visible PL emission at room temperature.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The temperature and velocity distributions of the air inside the cabinet of domestic refrigerators affect the quality of food products. If the consumer knows the location of warm and cold zones in the refrigerator, the products can be placed in the right zone. In addition, the knowledge of the thickness of thermal and hydrodynamic boundary layers near the evaporator and the other walls is also important. If the product is too close to the evaporator wall, freezing can occur, and if it is too close to warm walls, the products can be deteriorated. The aim of the present work is to develop a steady state computational fluid dynamics (CFD) model for domestic refrigerators working on natural convection regime. The Finite Volume Methodology is chosen as numerical procedure for discretizing the governing equations. The SIMPLE-Semi-Implicit Method for Pressure-Linked Equations algorithm applied to a staggered mesh was used for solving the pressure-velocity coupling problem. The Power-Law scheme is employed as interpolation function for the convective-diffusive terms, and the TDMA-Tri-Diagonal Matrix Algorithm is used to solve the systems of algebraic equations. The model is applied to a commercial static refrigerator, where the cabinet is considered an empty three-dimensional rectangular cavity with one drawer at the bottom of the cabinet, but without shelves. In order to analyze the velocity and temperature fields of the air flow inside the cabinet the evaporator temperature, Te, was varied from -20 degrees C to 0 degrees C, and nine different evaporator positions are evaluated for evaporator temperature of -15 degrees C. The cooling capacity of the evaporator for the steady state regime is also computed for each case. One can conclude that the vertical positioning of the evaporator inside the cabinet plays an important role on the temperature distribution inside the cabinet.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
MoO3 is a lamellar material with applications in different areas, as solid lubricants, catalysis, solar cells, etc. In the present work, MoO3 powders, synthesized by the polymeric precursor method, were doped with nickel or cobalt. The powder precursors were characterized by TG/DTA. After calcination between 500 and 700 degrees C, the samples were characterized by X-ray diffraction, infrared and Raman spectroscopy and scanning electron microscopy. beta-MoO3 was obtained after calcination at low temperatures. With the temperature increase, alpha-MoO3 is observed, with a preferential growth of the (0 2k 0) planes, when the material is doped and calcined at 700 degrees C. Doping with nickel increases five times the preferential growth. As a consequence, plate-like particles are observed. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
To study the influence of Ga addition on photoinduced effect, GaGeS glasses with constant atomic ratio S/Ge = 2.6 have been prepared. Using Raman spectroscopy, we have reported the effect of Ga on the structural behavior of these glasses. An increase of the glass transition temperature T(g), the linear refractive index and the density have been observed with increasing gallium content. The photoinduced phenomena have been examined through the influence of time exposure and power density, when exposed to above light bandgap (3.53 eV). The correlation between photoinduced phenomena and Ga content in such glasses are shown hereby. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The preparation of nanometer-sized structures of zinc oxide (ZnO) from zinc acetate and urea as raw materials was performed using conventional water bath heating and a microwave hydrothermal (MH) method in an aqueous solution. The oxide formation is controlled by decomposition of the added urea in the sealed autoclave. The influence of urea and the synthesis method on the final product formation are discussed. Broadband photoluminescence (PL) behavior in visible-range spectra was observed with a maximum peak centered in the green region which was attributed to different defects and the structural changes involved with ZnO crystals which were produced during the nucleation process.
Resumo:
1. The effect of bacterial endotoxin injection was studied in growing pullets of different ages. Commercial chicks were divided into 5 groups according to age. Bacterial endotoxins (E. coli and S. typhimurium) were injected intravenously and rectal temperature was measured over a period of 300 min. 2. The results showed no significant effect of age on the febrile response induced by bacterial endotoxins, but a slight tendency towards a reduced fever peak was observed with increasing age. The response latency also increased with age.
Resumo:
Thirty-two Polwarth sheep of ages up to 1 year were observed under temperatures varying from 10.5 to 46.5°C. The following blood cell counts were made: erythrocyte (RBC), leucocyte (WBC), eosinophil (EOS), neutrophil (NEU), lymphocyte (LYM) and monocyte (MON). Other traits measured were: haemoglobin (HB), haematocrit (HT), blood glucose (GLU) and serum protein (PROT). Multivariate analysis of variance was used and the results showed a significant (P<0.001) effect for the interaction of shearing and temperature treatment. Under temperatures >25°C, sheep presented a decrease of RBC, WBC, HB and HT, these differences being greater in the shorn than in the unshorn animals. Unshorn animals presented higher variations in EOS, NEU, LYM, MON and GLU. Blood glucose increased under high temperatures in the shorn animals (from 56.36±0.65 mg/100 ml to 60.52±0.69 mg/100 ml) as in the unshorn animals (from 54.72±0.74 mg/100 ml to 57.56±0.77 mg/100 ml). © 1992 International Society of Biometeorology.
Resumo:
Four trials of identical experimental design were conducted to determine the effects of temperature, dietary Lys level, and dietary Arg:Lys ratios on performance and carcass yield of male broilers. Birds of a commercial strain were grown from 21 to 42 d of age in wire-floored finishing batteries placed in environmental chambers. The chambers were programmed to provide either a constant thermoneutral temperature (21.1 C), a constant cold temperature (15.5 C), or a cycling hot diurnal temperature (25.5 to 33.3 C). Within each environment there was a factorial arrangement of three Lys levels (1.0, 1.1, and 1.2%) with four Arg:Lys ratios (1.1:1, 1.2:1, 1.3:1, and 1.4:1). Environmental temperature significantly influenced virtually every characteristic examined. Hot cyclic temperatures reduced weight gain, feed intake, and breast meat yield, and increased feed conversion, dressing percentage, leg quarter yield, and abdominal fat content. The cold environment promoted increased feed intake and mortality. Ascites and cardiomyopathy were the leading causes of death under cold exposure and thermoneutral conditions, whereas complications arising from heat exposure were the main cause of death under hot cyclic conditions. Levels of Lys affected leg quarter yield and abdominal fat content over all environments but increased breast meat yield only under cold conditions. Increasing Arg: Lys ratios improved feed conversion and dressing percentage and reduced abdominal fat content; it could not be determined whether these responses were consistent with Arg per se or were due to a nonspecific N response. As increasing Lys levels or Arg:Lys ratios did not improve weight gain, increase breast meat yield, or attenuate adverse effects due to heat or cold exposure, it is concluded that the levels of Lys and Arg suggested for 21 to 42 d by the NRC are adequate for birds of this age under the environmental conditions encountered.
Resumo:
The influence of silver additions on the structure and phase transformation of the Cu-13 wt % Al alloy was studied by differential thermal analysis, X-ray diffraction, scanning electron microscopy and energy dispersive analysis of X-rays. The results indicate that the presence of silver modifies the phase-stability field, the transition temperature and the structure of the alloy. These effects are more pronounced for silver concentrations up to 8 wt %.
Resumo:
The specific heat, thermal conductivity, thermal diffusivity and density of Brazilian orange juice were determined between 0.34 and 0.73 (w/w) water content and with temperatures from 0.5 to 62°C. The experimental data were fitted as functions of temperature and water content and all properties showed a linear dependency with these variables. In the tested range, the water content exhibited a greater influence on the analyzed properties than temperature. © 1998 Elsevier Science Limited. All rights reserved.
Resumo:
Canine brains infected with rabies virus were submitted to decomposition by being left at room temperature of 25 to 29 degrees C for up to 168 h. At 24 h intervals, brain fragments were analyzed by immunofluorescence (IF) and by the mouse intracerebral inoculation (MI) test to confirm the diagnosis of rabies and to measure the putrefaction effect on the accuracy of the diagnosis. Forty eight h after the beginning of the experiment, the MI test showed signs of impairment with four negative results, while after 72 h, 100% of the results were negative to the MI test and only one result was negative to the IF test, indicating that the threshold period for accurate diagnosis is 24 to 48 h before putrefaction. The authors recommend the shipment of suspected cases of rabies to the laboratory for confirmation, but the use of putrid materials for diagnosis is meaningless because of false-negative results.
Resumo:
Objective: The present study was performed to investigate the influence of different routes of perfusion on the distribution of the preservation solutions in the lung parenchyma and upper airways. Methods: Pigs were divided into four groups: control (n = 6), pulmonary artery (PA) (n = 6), simultaneous PA + bronchial artery (BA) (n = 8), and retrograde delivery (n = 6). After preparation and cannulation, cardioplegia solution and Euro- Collins solution (ECS) for lung preservation were given simultaneously. After removal of the heart, the double lung bloc was harvested. Following parameters were assessed: total and regional perfusion (dye-labeled microspheres), tissue water content, PA, aorta, left atrial and left ventricular pressures, cardiac output and lung temperature. Results: Our data show that flow of the ECS in lung parenchyma did not reach control values (9.4 ± 1.0 ml/min per g lung wet weight) regardless of the route of delivery (PA 6.3 ± 1.5, PA + BA 4.8 ± 0.9, retrograde 2.7 ± 0.9 ml/min per g lung wet weight). However, flow in the proximal and distal trachea were significantly increased by PA + BA delivery (0.970 ± 0.4, respectively, 0.380 ± 0.2 ml/min per g) in comparison with PA (0.023 ± 0.007, respectively, 0.024 ± 0.070 ml/min per g), retrograde (0.009 ± 0.003, respectively, 0.021 ± 0.006 ml/min per g) and control experiments (0.125 ± 0.0018, respectively, 0.105 ± 0.012 ml/g per min). Similarly the highest flow rates in the right main bronchus were achieved by PA + BA delivery (1.04 ± 0.4 ml/min per g) in comparison with 0.11 ± 0.03 in control, 0.033 ± 0.008 in PA, and 0.019 ± 0.005 ml/min per g in retrograde group. Flows in the left main bronchus were 0.09 ± 0.02 ml/min per g in control, 0.045 ± 0.012 ml/min per g in PA, and 0.027 ± 0.006 ml/min per g in retrograde group. The flow rates were significantly (P = 0.001) increased by PA + BA delivery of the storage solution (0.97 ± 0.3 ml/min per g). Conclusions: Our data show that the distribution of ECS for lung preservation is significantly improved in airway tissues (trachea and bronchi) if a simultaneous PA + BA delivery is used.