163 resultados para international physical distribution


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new methodology to evaluate in a predictive way the reliability of distribution systems, considering the impact of automatic recloser switches. The developed algorithm is based on state enumeration techniques with Markovian models and on the minimal cut set theory. Some computational aspects related with the implementation of the proposed algorithm in typical distribution networks are also discussed. The description of the proposed approach is carried out using a sample test system. The results obtained with a typical configuration of a Brazilian system (EDP Bandeirante Energia S.A.) are presented and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In some applications like fault analysis, fault location, power quality studies, safety analysis, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of particular interest. In order to investigate effects of neutrals and system grounding on the operation of the distribution feeders with faults, in this research a hybrid short circuit algorithm is generalized. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. Results obtained from several case studies using IEEE 34-node test network are presented and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brazil produced in 2002/03 season 317.87×106tons of sugar cane stalks and 36.88×106tons of vegetal residues (green leaves, dry leaves and tops) in a planted area of 4.61×106 hectares (ha). These residues have a useful heat of 3,613.14Mcal.t-1. Currently most of this biomass is burned as a pre-harvest practice. The doubt persists in the system type that it must be adopted to pick up, load, transport and unload this biomass at the sugar mill boilers. This study analyzed 22 variables related to operational costs and physical characteristics of these residues in a field situation using a JOHN DEERE® 6850 forage harvester with two different treatments: T1 and T2 (two types of rakes) with 6 repetitions each one. The geographic location of the studied area that belongs to COSTA PINTO MILL (COSAN® Group) is: Latitude 22°40'30S and Longitude 47°36'38W. The adopted methodology was proposed by Ripoli et al. (2002). The obtained results at a 5% level of significance showed that both treatments did not differed significantly between them. Some of the results were, where EBP stands for Oil Equivalent Barrel: Windrowing (T1=US$0.17.EBP-1 and US$9.59.ha-1, T2=US$0.08.EBP-1 and US$4.27.ha-1); Pick up (T1=US$1.31.EBP-1 and US$44.29.ha-1, T2 =US$1.37.EBP-1 and US$48.36.ha-1); Transportation (T1=US$1.27.EBP-1 and US$14,30.ha -1, T2=US$1.33.EBP-1 and US$14,80.ha -1), Unloading at the sugar mill (T1=US$0.30.EBP-1 and US$3.39.ha-1, T2=US$0.32.EBP-1 and US$3.51.ha-1); Total (T1=US$3.05.EBP-1 and US$71.57.ha-1, T2=US$3.10.EBP-1 and US$70.94.ha-1). Confronting the obtained data with the ones in the bibliography, this system revealed itself more expensive than the baling system or the integral harvest system using combines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to evaluate the bean yield under different water table levels as well as the moisture and nitrate distribution in the soil profile, a field experiment was carried out at the experimental area from the College of Agronomic Sciences - UNESP, Botucatu, SP, Brazil. Beans were grown in field lysimeters and subjected to five water table depths:30; 40; 50; 60 and 70 cm. The moisture in the soil profile was gravimetrically determined through samples obtained at 10; 20; 30; 40; 50; 60 and 70cm of depth. The water table depths of 30cm and 40cm showed the highest productivities (3,228.4 kg.ha-1 and 3,422.1 kg.ha-1, respectively), showing no statistical differences between each other. The highest productivity was related to the two most elevated water table levels (30 and 40cm), which provided the highest moisture average values on basis of volume in the soil profile (33.3 e 31%) as well as the consumptive use of water (416 and 396 mm). The nitrate content during the bean cycle at the extraction depth of 60cm has been under the safe drinking limit of 10 mg.1-1 for water table depths of 30; 40; 50 and 60cm, showing the denitrification effectiveness as a way of controlling water table from nitrate pollution. The water table handling allowed the attainment of high bean productivity levels, as well as the reduction of the nitrate level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents and describes in detail the pressure profile in a conical tube with the unavoidable steady-state outgassing, plus a transient gas source, like, for instance, in an accelerator, when particles from the beam hit the walls. Mathematical and physical formulations are given and detailed; specific conductance, specific throughput and a detailed discussion about the boundary conditions are presented. These concepts and approach are applied to usual realistic cases, such as conical tubes, with typical laboratory dimensions. © 2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to establish physical and chemical characterizations of dovyalis hybrid fruits (Dovyalis abyssinica and D. hebecarpa). Samples of 25 fruits were characterized by evaluation of length and width, weight, percentage and number of seeds per fruit, peel percentage, pulp percentage, total soluble solids (TSS), titratable acidity (TA), vitamin C and TSS/TA ratio. Dovyalis fruit has good physical quality for market with an average of 75% pulp. Vitamin C content averaged 120.3 mg/100 g of fresh fruit, characterizing dovyalis as a good source of vitamin C. © 2005 by The Haworth Press, Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot radial distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regulatory authorities in many countries, in order to maintain an acceptable balance between appropriate customer service qualities and costs, are introducing a performance-based regulation. These regulations impose penalties, and in some cases rewards, which introduce a component of financial risk to an electric power utility due to the uncertainty associated with preserving a specific level of system reliability. In Brazil, for instance, one of the reliability indices receiving special attention by the utilities is the Maximum Continuous Interruption Duration per customer (MCID). This paper describes a chronological Monte Carlo simulation approach to evaluate probability distributions of reliability indices, including the MCID, and the corresponding penalties. In order to get the desired efficiency, modern computational techniques are used for modeling (UML -Unified Modeling Language) as well as for programming (Object- Oriented Programming). Case studies on a simple distribution network and on real Brazilian distribution systems are presented and discussed. © Copyright KTH 2006.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to analyze temporal ..d vertical variation of the biomass and of phytoplankton primary productivity in an urban eutrophic reservoir, in relation to the physical and chemical characteristics of the water. The physical and chemical variables of the water were defined in the limnetic region of the reservoir, at depths of 0.0; 0.5; 1.0; 2.0; 3.0 and 4.0 meters. Three samples were taken to define both the physical and chemical variables, concomitantly with the biomass (chlorophyll-a and phaeophytin) and phytoplankton primary productivity (C-14 method). Based on data obtained on differences in depth of the mixture zone and the euphotic zone, it is hypothesised that, depending on the time of the year, phytoplankton is conditioned by differences in the light and nutrient regimes, which change according to the constant loads of nutrients thrown into the system. The highest concentration of chlorophyll-a in the photic zone of the limnetic region was observed in November 2000 (1,197.3 mg Chl L -1) and the lowest in November 1999 (94.0 mg ChI L -1), whereas the profiles of primary activity of phytoplankton presented the highest rates on the surface of the water column, with values varying from 84.7 (May 2000) to 1,376.7mg C m -3 h -1 (December 2000). Annual primary productivity was calculated at 1,567.0gC m -2y -1, considered euproductive. The primary productivity profiles reported in this study are typical of aquatic eutrophic systems, rich in plankton and with low light penetration. It can be stated that Garças Lake is a system that suffers from anthropogenic impact, through receiving large loads of organic pollution, reflecting on the physical and chemical characteristics of the water and on the high values of biomass and primary phytoplankton activity. © National Institute of Ecology, New Delhi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Habitat heterogeneity and use of physical and acoustic space in anuran communities in Southeastern Brazil. We intended to verify if structural and physiognomical characteristics of water bodies influence on the degree of overlap among calling sites of 23 anurans species, if anuran species use different calling sites in different water bodies, and if there is some relationship between the degree of advertisement call (based on seven call features) and calling site differentiation. Then, we determined calling sites (based in four variables) and recorded the advertisement call for anuran species that occurred in 10 water bodies of northwestern São Paulo State. We also determined the environmental heterogeneity (based in four environmental descriptors) for each water body. Males of most species used similar calling sites in each water body, probably because of the high uniformity of the environment, as a consequence of agricultural impacts on edge vegetation of the studied ponds. Most species (18 out of 19 species) called from different sites in the ponds where they occurred, which can be associated with differences in horizontal and vertical distribution of vegetation in the studied ponds. From the 19 species analyzed, only males of Pseudopaludicola aff. saltica called in sites with the same characteristics in different ponds. Advertisement call of Hylidae species was more similar to each other than were Leiuperidae and Leptodactylidae among themselves. The aquatic/terrestrial anurans (Bufonidae, Leiuperidae, Leptodactylidae and Microhylidae) occupied similar calling sites but presented quite distinct advertisement calls, while Hylidae species presented an inverse pattern: a high similarity on advertisement call features but used different calling sites, which indicates a niche complementarity between physical (calling site use) and acoustic (advertisement call) space use. © 2008 Departamento de Ciências Biológicas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In an evermore competitive environment, power distribution companies need to continuously monitor and improve the reliability indices of their systems. The network reconfiguration (NR) of a distribution system is a technique that well adapts to this new deregulated environment for it allows improvement of system reliability indices without the onus involved in procuring new equipment. This paper presents a reliability-based NR methodology that uses metaheuristic techniques to search for the optimal network configuration. Three metaheuristics, i.e. Tabu Search, Evolution Strategy, and Differential Evolution, are tested using a Brazilian distribution network and the results are discussed. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The architecture of proposed input stage converter is composed by five interleaved boost rectifiers operating in discontinuous conduction mode. Furthermore, due to the power lines characteristics, the proposed input power structure can act as AC to DC or as DC to DC converter providing a proper DC output voltage range required to the DC bus. When operation is AC to DC, the converter is capable to provide high power factor with reduced harmonic distortion for the input current, complying with the restrictions imposed by IEC 61000-3-4 standard. Finally, the main experimental results are presented in order to verify the feasibility of the proposed converter, demonstrating the benefits and the possibility for AC feeding system for trolleybus type vehicle. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Unbalance and harmonics are two major distortions in the three-phase distribution systems. In this paper an investigation into unbalance phenomena in the distribution networks using instantaneous space vector theory, is presented. Power oscillation index (POI) and effective power factor (PFe) are calculated in the network nodes for several unbalance loading conditions. For system analysis a general power flow algorithm for three-phase four-wire radial distribution networks, based on backward-forward technique, is applied. Results obtained from several case studies using medium and low voltage test feeder with unbalanced load, are presented and discussed. © 2010 Praise Worthy Prize S.r.l. - All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The business world has changed the way how people think and act on products and services. In this context, the most recent amendment of the scenarios of retail operations has been the use of technology in sales and distribution. The internet has revolutionized the way people communicate, and moreover as they purchase their goods and services. Thus, the e-commerce, specifically the relation business to customer, or simply B2C, has acted so convincingly in this change of paradigm, namely the purchases in the physical location for the virtual site. Quotes online, ease of payment, price, speed of delivery, have become real order winners of applications for companies that compete in this segment. With the focus on quality of services on e-commerce, the research examines the dimension related to the quality of services, and looks for what of these factors are winners of applications. © 2010 IFIP International Federation for Information Processing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this work is to present a frequency domain model to demonstrate the operation of an electromagnetic arrangement for controlling the injection of zero-sequence currents in the electrical system. Considering the diversity of sequential distribution of harmonic components of a current, the device proposed can be used in the process of mitigation of zero-sequence components. This device, here called electromagnetic suppressor, consists of a blocker and filter both electromagnetic, whose joint operation can provide paths of high and low impedances that can be conveniently adjusted in order to search for a desired performance. This study presents physical considerations, mathematical modeling and computer simulations that clearly demonstrate the viability of this application as a more viable alternative in the conception of filtering systems. The performance analysis is based on the frequency response of harmonic transmittances. The efficacy of this technique in direct actions to maximize the harmonic mitigation process is demonstrated. ©2010 IEEE.