110 resultados para Geostophic current


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the major similarities and discrepancies among three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire power circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what can be done by means of the CPT. © 2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mathematics education in Brazil, if we consider what one may call the scientific phase, is about 30 years old. The papers for this special issue focus mainly on this period. During these years, many trends have emerged in mathematics education to address the complex problems facing Brazilian society. However, most Brazilian mathematics educators feel that the separation of research into trends is a theoretical idealization that does not respond to the dynamics of the problems we face. We raise the conjecture that the complexity of Brazilian society, where pockets of wealth coexist with the most shocking poverty, has contributed to the adoption and generation of different strands in mathematics education, crossing the boundaries between trends. At a more micro level, we also raise the conjecture that Brazilian trends in research are interwoven because of the way that Brazilian mathematics educators have experienced the process of globalization over these 30 years. This tapestry of trends is a predominant characteristic of mathematics education in Brazil. © FIZ Karlsruhe 2009.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that the electromagnetic current for a system composed by two charged bosons has a structure of many bodies even in the impulse approximation, when described in the time x +. In terms of the two body component for the bound state, the current contains two body operators. We discuss the process of pair creation by the photon and interpret it as a zero mode contribution to the current and its consequences for the components of currents in the light front. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper. © 2010 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between electrical substations and transmission line protection. However, with the increasing use of optical fiber to communication (due mainly to its high data transmission rate and low signal-noise relation) this application loses potentiality. Therefore, other functions must be defined to equipments that are still in using, one of them is detecting faults (short-circuits) and transmission lines insulator strings damages 2. The purpose of this paper is to verify the possibility of using the path to the ground offered by the CTs instead of capacitive couplings / capacitive potential transformers to detect damaged insulators, since the current transformers are always present in all transmission lines (TL's) bays. To this a comparison between this new proposal and the PLC previous proposed system 2 is shown, evaluating the economical and technical points of view. ©2010 IEEE.