234 resultados para Diode parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The health-promoting effects of exercise training (ET) are related to nitric oxide (NO) production and/or its bioavailability. The objective of this study was to determine whether single nucleotide polymorphism of the endothelial NO synthase (eNOS) gene at positions -786T>C, G894T (Glu298Asp) and at the variable number of tandem repeat (VNTR) Intron 4b/a would interfere with the cardiometabolic responses of postmenopausal women submitted to physical training. Forty-nine postmenopausal women were trained in sessions of 30-40 min, 3 days a week for 8 weeks. Genotypes, oxidative stress status and cardiometabolic parameters were then evaluated in a double-blind design. Both systolic and diastolic blood pressure values were significantly reduced after ET, which was genotype-independent. However, women without eNOS gene polymorphism at position -786T>C (TT genotype) and Intron 4b/a (bb genotype) presented a better reduction of total cholesterol levels (-786T>C: before = 213 ± 12.1, after = 159.8 ± 14.4, Δ = -24.9% and Intron 4b/a: before = 211.8 ± 7.4, after = 180.12 ± 6.4 mg/dL, Δ = -15%), and LDL cholesterol (-786T>C: before = 146.1 ± 13.3, after = 82.8 ± 9.2, Δ = -43.3% and Intron 4b/a: before = 143.2 ± 8, after = 102.7 ± 5.8 mg/dL, Δ = -28.3%) in response to ET compared to those who carried the mutant allele. Superoxide dismutase activity was significantly increased in trained women whereas no changes were observed in malondialdehyde levels. Women without eNOS gene polymorphism at position -786T>C and Intron 4b/a showed a greater reduction of plasma cholesterol levels in response to ET. Furthermore, no genotype influence was observed on arterial blood pressure or oxidative stress status in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate gait spatial parameters at the point of departure, with obstacle heights adjusted to individual body scale. Undergraduate student volunteers (M age=22.4 yr., SD=2.1; 6 women, 1 man) were asked to step once, then cross over an obstacle and stop. This behavior was video recorded to extract kinematic data. The obstacle heights corresponded to high (knee-height) and low obstacles (half the knee-height). Points of departure corresponded to far (length of the lower limb) and close (half the length of the lower limb). The close point of departure influenced the trailing foot's placement ahead of the obstacle as well as step length. The high obstacle influenced the trailing foot's toe clearance. An interaction between factors was observed for leading foot toe clearance. Results indicate that body scale affected the participants' locomotor behavior during the obstacle-avoidance task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the effect of an 830-nm gallium-aluminum-arsenic (GaAlAs) diode laser at two different energy densities (5 and 15 J/cm(2)) on the epiphyseal cartilage of rats by evaluating bone length and the number of chondrocytes and thickness of each zone of the epiphyseal cartilage. Background Data: Few studies have been conducted on the effects of low-level laser therapy on the epiphyseal cartilage at different irradiation doses. Materials and Methods: A total of 30 male Wistar rats with 23 days of age and weighing 90 g on average were randomly divided into 3 groups: control group (CG, no stimulation), G5 group (energy density, 5 J/cm(2)), and G15 group (energy density, 15 J/cm(2)). Laser treatment sessions were administered every other day for a total of 10 sessions. The animals were killed 24 h after the last treatment session. Histological slides of the epiphyseal cartilage were stained with hematoxylin-eosin (HE), photographed with a Zeiss photomicroscope, and subjected to histometric and histological analyses. Statistical analysis was performed using one-way analysis of variance followed by Tukey's post hoc test. All statistical tests were performed at a significance level of 0.05. Results: Histological analysis and x-ray radiographs revealed an increase in thickness of the epiphyseal cartilage and in the number of chondrocytes in the G5 and G15 groups. Conclusion: The 830-nm GaAlAs diode laser, within the parameters used in this study, induced changes in the thickness of the epiphyseal cartilage and increased the number of chondrocytes, but this was not sufficient to induce changes in bone length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of large amounts of data is better performed by humans when represented in a graphical format. Therefore, a new research area called the Visual Data Mining is being developed endeavoring to use the number crunching power of computers to prepare data for visualization, allied to the ability of humans to interpret data presented graphically.This work presents the results of applying a visual data mining tool, called FastMapDB to detect the behavioral pattern exhibited by a dataset of clinical information about hemoglobinopathies known as thalassemia. FastMapDB is a visual data mining tool that get tabular data stored in a relational database such as dates, numbers and texts, and by considering them as points in a multidimensional space, maps them to a three-dimensional space. The intuitive three-dimensional representation of objects enables a data analyst to see the behavior of the characteristics from abnormal forms of hemoglobin, highlighting the differences when compared to data from a group without alteration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with noise removal by the use of an edge preserving method whose parameters are automatically estimated, for any application, by simply providing information about the standard deviation noise level we wish to eliminate. The desired noiseless image u(x), in a Partial Differential Equation based model, can be viewed as the solution of an evolutionary differential equation u t(x) = F(u xx, u x, u, x, t) which means that the true solution will be reached when t ® ¥. In practical applications we should stop the time ''t'' at some moment during this evolutionary process. This work presents a sufficient condition, related to time t and to the standard deviation s of the noise we desire to remove, which gives a constant T such that u(x, T) is a good approximation of u(x). The approach here focused on edge preservation during the noise elimination process as its main characteristic. The balance between edge points and interior points is carried out by a function g which depends on the initial noisy image u(x, t0), the standard deviation of the noise we want to eliminate and a constant k. The k parameter estimation is also presented in this work therefore making, the proposed model automatic. The model's feasibility and the choice of the optimal time scale is evident through out the various experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of endodontic treatment depends on the complete elimination of microorganisms from the root canal system, thus the search for new procedures to eliminate them is justified. The aim of this study was to assess bacterial reduction after intracanal irradiation with the Er:YAG laser. The canals of 70 extracted human maxillary canines were prepared up to file #40 using 1% NaOCl, irrigated with 17% EDTA, and then washed with physiological solution activated by ultrasound. The roots were sterilized by autoclaving, inoculated with 10 mu l of a suspension containing 1.5 x 10(8) CFU/ml of Enterococcus faecalis ATCC 29212 and incubated at 37A degrees C for 72 h. The canals were irradiated with the Er:YAG laser using two energy settings: 60 mJ and 15 Hz, and 100 mJ and 10 Hz. The remaining bacteria were counted immediately and 48 h after laser irradiation. The results showed a high bacterial reduction at both time points. With 60 mJ and 15 Hz there was an immediate reduction of 99.73% and the reduction was 77.02% after 48 h, and with 100 mJ and 10 Hz there was an immediate reduction of 99.95% and the reduction was 84.52% after 48 h. Although the best results were observed with 100 mJ of energy, the difference between the two settings was not statistically significant. The count performed 48 h after irradiation showed that E. faecalis were able to survive, and can grow even from small numbers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Recently, there has been an increasing in the impact of oral health on atherosclerosis and subsequent cardiovascular disease. The aim of this study is to investigate the association between chronic periodontitis and cardiovascular risk markers.Methods: Forty patients with periodontitis and 40 healthy gender-, body mass index-, and age-matched individuals were compared by measuring total cholesterol, high-density lipoprotein, low-density lipoprotein, triglycerides, levels of cytokines, antibodies against oxidized low-density lipoprotein, thiobarbituric acid reactive substances, total and differential white blood cell counts, and the non-linear index of refraction.Results: The levels of triglycerides and high-density lipoprotein in periodontitis patients were significantly higher and lower, respectively (P=0.002 and P=0.0126), compared to controls. Total cholesterol, low-density lipoprotein, and lipid peroxide levels were the same in both groups (P = 0.2943, P = 0.1284, and P = 0.067, respectively). Interleukin (IL)-6 and -8, antibodies against oxidized low-density lipoprotein, and leukocyte and neutrophil counts were significantly higher in periodontitis patients (P<0.05). The value of the non-linear index of refraction of low-density lipoprotein solutions was higher in the controls (P = 0.015) compared to individuals with periodontitis.Conclusion: Our results confirmed and further strengthened the suggested association between coronary artery disease and periodontitis. J Periodontol 2009;80:378-388.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.