112 resultados para mammography screening


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The huge demand for procedures involving ionizing radiation promotes the need for safe methods of experimentation considering the danger of their biological e ects with consequent risk to humans. Brazilian's legislation prohibits experiments involving this type of radiation in humans through Decree 453 of Ministry of Health with determines that such procedures comply with the principles of justi cation, optimization and dose limitation. In this line, concurrently with the advancement of available computer processing power, computing simulations have become relevant in those situations where experimental procedures are too cost or impractical. The Monte Carlo method, created along the Manhattan Project duringWorldWar II, is a powerful strategy to simulations in computational physics. In medical physics, this technique has been extensively used with applications in diagnostics and cancer treatment. The objective of this work is to simulate the production and detection of X-rays for the energy range of diagnostic radiology, for molybdenum target, using the Geant4 toolkit. X-ray tubes with this kind of target material are used in diagnostic radiology, speci cally in mammography, one of the most used techniques for screening of breast cancer in women. During the simulations, we used di erent models for bremsstrahlung available in physical models for low energy, in situations already covered by the literature in earlier versions of Geant4. Our results show that although the physical situations seems qualitatively adequate, quantitative comparisons to available analytical data shows aws in the code of Geant4 Low Energy source

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local anesthetic articaine (ATC) is widely used in dentistry; however, its side effects can include paresthesia and nerve injury. Polymeric nanocapsules (PN) can be used as carriers for drugs, and help to reduce undesirable symptoms. The objective of this study was to evaluate the influence of different factors on the average size, polydispersion, and encapsulation efficiency of PN containing ATC. Poly(ε-caprolactone) (PCL) nanocapsules containing ATC were prepared by the oil-in-water emulsion/solvent evaporation method. The final ATC concentration was 2%. The preparation conditions were optimized using a central composite blocked cube-star design to investigate the influence of two variables at five levels, with 22 factorial points (–1 and +1), two replicates of the central point, 2×2 axial points (–1.414 and +1.414), and an orthogonal distribution, resulting in 10 experiments. The factors varied were the PVA concentration and the sonication time. The nanocapsules showed a satisfactory size range, a polydispersivity index less than 0.2, and high encapsulation efficiency. The values of the factors had no significant influence on either average size or polydispersion, although the encapsulation efficiency was significantly influenced by the sonication time. Improved formulations were identified using the central composite design, which revealed that the main consideration in selecting a suitable formulation was the encapsulation efficiency. Two of the formulations showed both high encapsulation efficiency and colloidal characteristics appropriate for the route of administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aprefeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current response to intervention models (RTIs) favor a three-tier system. In general, Tier 1 consists of evidence-based, effective reading instruction in the classroom and universal screening of all students at the beginning of the grade level to identify children for early intervention. Non-responders to Tier 1 receive small-group tutoring in Tier 2. Nonresponders to Tier 2 are given still more intensive, individual intervention in Tier 3. Limited time, personnel and financial resources derail RTI's implementation in Brazilian schools because this approach involves procedures that require extra time and extra personnel in all three tiers, including screening tools which normally consist of tasks administered individually. We explored the accuracy of collectively and easily administered screening tools for the early identification of second graders at risk for dyslexia in a two-stage screening model. A first-stage universal screening based on collectively administered curriculum-based measurements was used in 45 7 years old early Portuguese readers from 4 second-grade classrooms at the beginning of the school year and identified an at-risk group of 13 academic low-achievers. Collectively administered tasks based on phonological judgments by matching figures and figures to spoken words [alternative tools for educators (ATE)] and a comprehensive cognitive-linguistic battery of collective and individual assessments were both administered to all children and constituted the second-stage screening. Low-achievement on ATE tasks and on collectively administered writing tasks (scores at the 25th percentile) showed good sensitivity (true positives) and specificity (true negatives) to poor literacy status defined as scores <= 1 SD below the mean on literacy abilities at the end of fifth grade. These results provide implications for the use of a collectively administered screening tool for the early identification of children at risk for dyslexia in a classroom setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare cervical cytology test results among pregnant and non-pregnant women, and to assess associations with age, screening history, and onset of sexual intercourse. Methods: A retrospective analysis was conducted of cervical smears obtained from women aged 18-34 years in the Campinas region of Brazil between January 2000 and December 2009. Eligible participants had not undergone cytological screening within the previous year and had no history of precursor lesions or cervical cancer. Multinomial logistic regression was performed for different age groups, with high-grade squamous intraepithelial lesions (HSILs) as the endpoint. Results: Overall, 3072 (0.4%) of 861 353 non-pregnant women and 135 (0.4%) of 37 568 pregnant women had HSILs. Odds of HSIL among pregnant and non-pregnant women did not differ in any age group. An increased age at first sexual intercourse among pregnant women reduced odds of HSILs in all age groups (odds ratio 0.9 [95% confidence interval 0.8-0.9] for all). Among women aged 21-24 years, 25-29 years, and 30-34 years, some associations were identified between an interval of less than 5 years since previous screening and reduced odds of HSILs. Conclusion: Mandatory cervical cytology screening does not seem to be necessary for pregnant women; protocols in place for non-pregnant women should be followed. (C) 2015 Published by Elsevier Ireland Ltd. on behalf of International Federation of Gynecology and Obstetrics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)