253 resultados para Fixed Points
Resumo:
Dento-alveolar process fracture is an important and common event in the dental office practice usually managed under the well-established protocols, but sometimes this kind of lesion is evaluated in the hospital emergency rooms without attention to the dental injuries. In this type of trauma, the time between the injury and the definitive resolution is essential for the treatment success, usually 1 h in cases of dento-alveolar fractures (tooth and alveolar bone). This paper describes the management of a patient with unusual dento-alveolar fracture caused by gunshot and treated using screw fixation.
Resumo:
Several biological phenomena have a behavior over time mathematically characterized by a strong increasing function in the early stages of development, then by a less pronounced growth, sometimes showing stability. The separation between these phases is very important to the researcher, since the maintenance of a less productive phase results in uneconomical activity. In this report we present methods of determining critical points in logistic functions that separate the early stages of growth from the asymptotic phase, with the aim of establishing a stopping critical point in the growth and on this basis determine differences in treatments. The logistic growth model is fitted to experimental data of imbibition of arariba seeds (Centrolobium tomentosum). To determine stopping critical points the following methods were used: i) accelerating growth function, ii) tangent at the inflection point, iii) segmented regression; iv) modified segmented regression; v) non-significant difference; and vi) non-significant difference by simulation. The analysis of variance of the abscissas and ordinates of the breakpoints was performed with the objective of comparing treatments and methods used to determine the critical points. The methods of segmented regression and of the tangent at the inflection point lead to early stopping points, in comparison with other methods, with proportions ordinate/asymptote lower than 0.90. The non-significant difference method by simulation had higher values of abscissas for stopping point, with an average proportion ordinate/asymptote equal to 0.986. An intermediate proportion of 0.908 was observed for the acceleration function method.
Resumo:
Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals.Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants.Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations.Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.
Resumo:
Objectives: To evaluate the accuracy of three different cutoff points for the detection of high blood pressure in adolescents, given the strong relationship between overweight and high blood pressure levels.Methods: A total of 1,021 adolescents of both sexes were enrolled in the study, selected at random from public and private schools in Londrina, Brazil. Their body weight was measured using a digital balance, and their height with a portable stadiometer with a maximum extension of 2 meters. Arterial blood pressure was measured using an automatic apparatus. The capacity of body mass index to detect high blood pressure was gauged using ROC curves and their parameters (sensitivity, specificity, and area under the curve).Results: The cutoff points proposed in a Brazilian standard exhibited greater accuracy (males: 0.636 +/- 0.038; females: 0.585 +/- 0.043) than the cutoff points proposed in an international (males: 0.594 +/- 0.040; females: 0.570 +/- 0.044) and a North-American standard (males: 0.612 +/- 0.039; females: 0.578 +/- 0.044).Conclusions: The Brazilian proposal offered greatest accuracy for indicating high blood pressure levels.
Resumo:
OBJETIVO: O objetivo deste estudo foi analisar as características cinemáticas, cinéticas e eletromiográficas do andar de adultos jovens em piso fixo sem colete e com suporte parcial de peso (SPP) de 0, 10, 20 e 30% do peso corporal. MÉTODO: Oito jovens com idade média de 22,2 anos foram filmados andando sobre uma passarela que continha uma plataforma de força na região central para registro das componentes da força de reação do solo. Marcadores refletivos foram posicionados nos principais pontos anatômicos dos membros inferiores para registro dos dados cinemáticos, e eletrodos de superfície foram afixados nos músculos tibial anterior e gastrocnêmio medial para registro da atividade elétrica muscular. RESULTADOS: Diferenças significantes entre as cinco condições experimentais foram constatadas nas variáveis espaço-temporal, nos ângulos máximos e mínimos da coxa, joelho e tornozelo e nas amplitudes das componentes horizontal ântero-posterior e vertical da força de reação do solo. de forma geral, as maiores mudanças ocorreram na condição de SPP de 30% do peso corporal. CONCLUSÃO: É importante considerar as compensações que ocorrem no padrão do andar com SPP no planejamento das intervenções terapêuticas. Ainda, para melhor definir a utilização dos sistemas de suspensão de peso na reabilitação, estudos futuros precisam ser realizados para verificar o comportamento do andar em populações com alteração de movimento em piso fixo.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to quantitatively evaluate and qualitatively describe autogenous bone graft healing with or without an expanded polytetrafluoroethylene (e-PTFE) membrane in ovariectornized rats. Materials and Methods: Eighty Wistar rats, weighing approximately 300 g each, were used. A graft was obtained from the parietal bone and fixed to the sidewall of each animal's left mandibular ramus. The animals were randomly divided into four experimental groups (n = 20 in each group): group 1, sham operated and autogenous bone graft only- group 2, sham operated and autogenous bone graft covered by e-PTFE membrane; group 3, ovariectornized (OVX) and autogenous bone graft only- group 4, OVX and autogenous bone graft covered by e-PTFE membrane. The animals were sacrificed at five different time points: immediately after grafting or at 7, 21, 45, or 60 days after grafting. Histologic examination and morphometric measurement of the sections were performed, and values were submitted to statistical analyses. Results: Both groups (sham and OVX) experienced loss of the original graft volume when it was not covered by the membrane, whereas use of the membrane resulted in additional bone formation beyond the edges of the graft and under the membrane. Histologic analysis showed integration of the grafts in all animals, although a larger number of marrow spaces was found in OVX groups. Conclusions: Association of bone graft with an e-PTFE membrane resulted in maintenance of its original volume as well as formation of new bone that filled the space under the membrane. Osteopenia did not influence bone graft repair, regardless of whether or not it was associated with e-PTFE membrane, but descriptive histologic analysis showed larger numbers of marrow spaces in the bone graft and receptor bed and formation of new bone in the OVX animals. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:1074-1082
Resumo:
Purpose: To evaluate the flexural strength of two fixed dental prosthesis (FDP) designs simulating frameworks of adhesive fixed partial prostheses, reinforced or not by glass fiber.Materials and Methods: Forty specimens, made with composite resin, were divided into 4 groups according to the framework design and the presence of fiber reinforcement: A1 - occlusal support; A2: occlusal support + glass fiber; B1: occlusal and proximal supports; B2: occlusal and proximal supports + glass fiber. The specimens were subjected to the three-point bending test, and the data were submitted to two-way ANOVA and Tukey's test (5%).Results: Group A2 (97.9 +/- 38 N) was statistically significantly different from all other experimental groups, presenting a significantly lower mean flexural strength.Conclusion: The use of glass fibers did not improve the flexural strength of composite resin, and designs with occlusal and proximal supports presented better results than designs simulating only occlusal support.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The problem of a spacecraft orbiting the Neptune-Triton system is presented. The new ingredients in this restricted three body problem are the Neptune oblateness and the high inclined and retrograde motion of Triton. First we present some interesting simulations showing the role played by the oblateness on a Neptune's satellite, disturbed by Triton. We also give an extensive numerical exploration in the case when the spacecraft orbits Triton, considering Sun, Neptune and its planetary oblateness as disturbers. In the plane a x I (a = semi-major axis, I = inclination), we give a plot of the stable regions where the massless body can survive for thousand of years. Retrograde and direct orbits were considered and as usual, the region of stability is much more significant for the case of direct orbit of the spacecraft (Triton's orbit is retrograde). Next we explore the dynamics in a vicinity of the Lagrangian points. The Birkhoff normalization is constructed around L-2, followed by its reduction to the center manifold. In this reduced dynamics, a convenient Poincare section shows the interplay of the Lyapunov and halo periodic orbits, Lissajous and quasi-halo tori as well as the stable and unstable manifolds of the planar Lyapunov orbit. To show the effect of the oblateness, the planar Lyapunov family emanating from the Lagrangian points and three-dimensional halo orbits are obtained by the numerical continuation method. Published by Elsevier Ltd. on behalf of COSPAR.