121 resultados para Atomic Units


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of light and temperature on germination of Brachiaria decumbens as well as the action of some dormancy breaking chemicals were tested. Two seed batches stored different times were used. The results show that seeds failed to respond to alternating temperature regimes and different light qualities. Seeds were indifferent to white light at 25 degrees C. KNO3, ethanol and H2SO4 failed to break seed dormancy, whereas KCN and H2O2 partially reduced dormancy of two month stored seeds. The results suggest a metabolic character of dormancy in ''new'' (freshly collected) seeds and confirm the occurence of two types of dormancy in B. decumbens seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with I'd as chemical modifier. The efficiency of As and Ge as internal standards for 25 mu g L-1 Se plus 500 mu g (L)-1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis gamma) versus analyte (axis x). The equations that describe the linear regression were: A(As)= - 0.004 +/- 0.019 +/- 1.02 + 0.019 A(Se) (r=0.9967 +/- 0.005); A(Ge)= - 0.0 17 +/- 0.015 + 1.01 +/- 0.015 A(Se) (r = 0.9978 +/- 0.004). Samples and reference solutions were automatically spiked with 500 mu g L-1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 mu L of aqueous standard solutions, analytical curves in the 5.00-40.0 mu g L-1 Se range were established using the ratio of Se absorbance to internal standard absorbance (A(Se)A(IS)) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 mu g L-1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 mu g L-1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99-105% range with IS and in the 70-80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 mu g L-1. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of using internal standardization (IS) to correct for interferences in hydride generation with in situ trapping in graphite furnace was evaluated. Arsenic was chosen as internal standard for Sb determination and Ir was used as permanent modifier. Fluctuations in the main parameters that affect the analytical results were minimized by IS and an effective contribution was verified in the studies of liquid phase interferences. Cobalt and Ni2+ were selected to illustrate the potential use of IS on the correction of interference by transition metals. The application of IS allows the Sb determination in samples containing up to 20-fold higher concentration of the Co2+ and Ni2+ when compared to the procedure without IS. The relative standard deviation of measurements varied from 0.3% to 0.7% and from 1.1% to 3.2% with and without IS, respectively. Recoveries within 92% and 107% of spiked aqueous solution containing Sb(III) and Sb(V) were found. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different kinds of modifiers and coatings on the integrated platform of transversely heated graphite atomizer (THGA) have been tested for the simultaneous determination of two group of elements: the first, the more volatile, formed by arsenic, bismuth, lead, antimony and selenium; the second, the less volatile, formed by cobalt, chromium, cupper, iron and manganese in milk by electrothermal atomic absorption spectrometry. Different Rh-modifiers were studied, such as Rh-coated platforms (Rh), carbide plus rhodium coated platforms (W-Rh, Zr-Rh), carbide-coated platforms (W and Zr) with co-injection of RhCl3, solutions and uncoated platforms with injection of solutions of Pd(NO3)(2), Mg(NO3)(2), and RhCl3. Milk samples were diluted 1:10 in 1.0% HNO3 and injected into the tube. The mass of modifier deposited and co-injected in the tube and the use of end capped tubes were also evaluated in order to improve the electrothermal behavior of analytes. Integrated platform pretreated with W plus co-injection RhCl3 for first group and pretreated with W-Rh for second group were elected. For 20 mu L injected samples the analytical curves in the 5.0-20.0 mu g L-1 concentration range have good linear correlation coefficients (r > 0.998). Relative standard deviations (n = 12) are < 6% and the calculated characteristic masses are between 5 pg and 62 pg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND:Guidelines for red blood cell (RBC) transfusions exist; however, transfusion practices vary among centers. This study aimed to analyze transfusion practices and the impact of patients and institutional characteristics on the indications of RBC transfusions in preterm infants.STUDY DESIGN and METHODS:RBC transfusion practices were investigated in a multicenter prospective cohort of preterm infants with a birth weight of less than 1500 g born at eight public university neonatal intensive care units of the Brazilian Network on Neonatal Research. Variables associated with any RBC transfusions were analyzed by logistic regression analysis.RESULTS:Of 952 very-low-birth-weight infants, 532 (55.9%) received at least one RBC transfusion. The percentages of transfused neonates were 48.9, 54.5, 56.0, 61.2, 56.3, 47.8, 75.4, and 44.7%, respectively, for Centers 1 through 8. The number of transfusions during the first 28 days of life was higher in Center 4 and 7 than in other centers. After 28 days, the number of transfusions decreased, except for Center 7. Multivariate logistic regression analysis showed higher likelihood of transfusion in infants with late onset sepsis (odds ratio [OR], 2.8; 95% confidence interval [CI], 1.8-4.4), intraventricular hemorrhage (OR, 9.4; 95% CI, 3.3-26.8), intubation at birth (OR, 1.7; 95% CI, 1.0-2.8), need for umbilical catheter (OR, 2.4; 95% CI, 1.3-4.4), days on mechanical ventilation (OR, 1.1; 95% CI, 1.0-1.2), oxygen therapy (OR, 1.1; 95% CI, 1.0-1.1), parenteral nutrition (OR, 1.1; 95% CI, 1.0-1.1), and birth center (p < 0.001).CONCLUSIONS:The need of RBC transfusions in very-low-birth-weight preterm infants was associated with clinical conditions and birth center. The distribution of the number of transfusions during hospital stay may be used as a measure of neonatal care quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The atomic superradiant emission is treated in the single-particle mean-field approximation. A single-particle Hamiltonian, which represents a dressed two-level atom in a radiation field, can be obtained and it is verified that it describes the transient regime of the emission process. While the line-shape emission for a bare atom follows the sech2 law, for the dressed atom the line shape deviates appreciably from this law and it is verified that the deviation depends crucially on the ratio of the dynamic frequency shift to the transition frequency. This kind of deviation is observed in experimental results. © 1990 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of light and temperature on germination of Brachiaria decumbens as well as the action of some dormancy breaking chemicals were tested. Two seed batches stored different times were used. The results show that seeds failed to respond to alternating temperature regimes and different light qualities. Seeds were indifferent to white light at 25°C. KNO3, ethanol and H2SO4 failed to break seed dormancy, whereas KCN and H2O2 partially reduced dormancy of two month stored seeds. The results suggest a metabolic character of dormancy in new (freshly collected) seeds and confirm the occurence of two types of dormancy in B. decumbens seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a new high power factor three-phase rectifier based on a Y-connected differential autotransformer with reduced kVA and 18-pulse input current followed by three DC-DC boost converters. The topology provides a regulated output voltage and natural three-phase input power factor correction. The lowest input current harmonic components are the 17th and the 19th. Three boost converters, with constant input currents and regulated parallel connected output voltages are used to process 4kW each one. Analytical results from Fourier analyses of winding currents and the vector diagram of winding voltages are presented. Simulation results to verify the proposed concept and experimental results are shown in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow-injection system with a Chelite-S® cationic resin packed minicolumn is proposed for the determination of trace levels of mercury in agroindustrial samples by cold vapor atomic absorption spectrometry. Improved sensitivity and selectivity are attained since mercuric ions are on-line concentrated whereas other potential interferents are discarded. With on-line reductive elution procedure, concentrated hydrochloric acid could be replaced by 10% w/v SnCl2, in 6 M HCl as eluent. The reversed-intermittent stream either carries the atomic mercury, to the flow cell in the forward direction or removes the residue from reactor/gas liquid separator to a discarding flask in the opposite direction. Concentration and volume of reagent, acidity, flow rates, commutation times and potential interfering species were investigated. For 120 s preconcentration time, the proposed system handles about 25 samples h-1 (50.0 500 ng l-1), consuming about 10 ml sample and 5 mg SnCl2 per determination. The detection limit is 0.8 ng l-1 and the relative standard deviation (RSD) (n = 12) of a 76.7 ng l-1 sample is about 5%. Results are in agreement with certified value of standard materials at 95% confidence level and good recoveries (97-128%) of spiked samples were found. (C) 2000 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The atomic tunneling between two tunnel-coupled Bose-Einstein condensates (BECs) in a double-well time-dependent trap was studied. For the slowly varying trap, synchronization of oscillations of the trap with oscillations of the relative population was predicted. Using the Melnikov approach, the appearance of the chaotic oscillations in the tunneling phenomena between the condensates was confirmed.