109 resultados para Visualization Of Interval Methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two methods to evaluate the state transition matrix are implemented and analyzed to verify the computational cost and the accuracy of both methods. This evaluation represents one of the highest computational costs on the artificial satellite orbit determination task. The first method is an approximation of the Keplerian motion, providing an analytical solution which is then calculated numerically by solving Kepler's equation. The second one is a local numerical approximation that includes the effect of J(2). The analysis is performed comparing these two methods with a reference generated by a numerical integrator. For small intervals of time (1 to 10s) and when one needs more accuracy, it is recommended to use the second method, since the CPU time does not excessively overload the computer during the orbit determination procedure. For larger intervals of time and when one expects more stability on the calculation, it is recommended to use the first method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The autonomic dysfunction stands out among the complications associated to diabetes mellitus (DM) and may be evaluated through the heart rate variability (HRV), a noninvasive tool to investigate the autonomic nervous system that provides information of health impairments and may be analyzed by using linear and nonlinear methods. Several studies have shown that HRV measured in a linear form is altered in DM. Nevertheless, a few studies investigate the nonlinear behavior of HRV. Therefore, this study aims at gathering information regarding the autonomic changes in subjects with DM identified by nonlinear analysis of HRV.Methods: For that, searches were performed on Medline, SciELO, Lilacs and Cochrane databases using the crossing between the key-words: diabetic autonomic neuropathy, autonomic nervous system, diabetes mellitus and heart rate variability. As inclusion criteria, articles published on a period from 2000 to 2010 with DM type land type II population which assessed the autonomic nervous system by nonlinear indices HRV were considered.Results: The electronic search resulted in a total of 1873 references with the exclusion of 1623 titles and abstracts and from the 250 abstracts remaining, 8 studies were selected to the final analysis that completed the inclusion criteria.Conclusions: In general, the analysis showed that the nonlinear techniques of HRV allowed detecting autonomic changes in DM. The methods of nonlinear analysis are indicated as a possible tool to be used for early diagnosis and prognosis of autonomic dysfunction in DM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The N-methyl-D-aspartate receptor antagonist ketamine and its active enantiomer, S(+)-ketamine, have been injected in the epidural and subarachnoid spaces to treat acute postoperative pain and relieve neuropathic pain syndrome. In this study we evaluated the effects of a single dose of preservative-free S(+)-ketamine, in doses usually used in clinical practice, in the spinal cord and meninges of dogs.METHODS: Under anesthesia (IV etomidate (2 mg/kg) and fentanyl (0.005 mg/kg), 16 dogs (6 to 15 kg) were randomized to receive a lumbar intrathecal injection (L5/6) of saline solution of 0.9% (control group) or S(+)-ketamine 1 mg/kg(-1) (ketamine group). All doses were administered in a volume of 1 mL over a 10-second interval. Accordingly, injection solution ranged from 0.6% to 1.5%. After 21 days of clinical observation, the animals were killed; spinal cord, cauda equine root, and meninges were removed for histological examination with light microscopy. Tissues were examined for demyelination (Masson trichrome), neuronal death (hematoxylin and eosin) and astrocyte activation (glial fibrillary acidic protein).RESULTS: No clinical or histological alterations of spinal tissue or meninges were found in animals from either control or ketamine groups.CONCLUSION: A single intrathecal injection of preservative-free S(+)-ketamine, at 1 mg/kg-1 dosage, over a concentration range of 6 to 15 mg/mL injected in the subarachnoid space in a single puncture, did not produce histological alterations in this experimental model. (Anesth Analg 2012;114:450-55)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Although the motile sperm organelle morphology examination (MSOME) was developed only as a selection criterion, its application as a method for classifying sperm morphology may represent an improvement in evaluation of semen quality, with potential clinical repercussions. The present study aimed to evaluate individual variations in the motile sperm organelle morphology examination (MSOME) analysis after a time interval.Methods: Two semen samples were obtained from 240 men from an unselected group of couples undergoing infertility investigation and treatment. Mean time interval between the two semen evaluations was 119 +/- 102 days. No clinical or surgical treatment was realized between the two observations. Spermatozoa were analyzed at greater than or equal to 8400 x magnification by inverted microscope equipped with DIC/Nomarski differential interference contrast optics. At least 200 motile spermatozoa per semen sample were evaluated and percentages of normal spermatozoa and spermatozoa with large nuclear vacuoles (LNV/one or more vacuoles occupying >50% of the sperm nuclear area) were determined. A spermatozoon was classified as morphologically normal when it exhibited a normal nucleus (smooth, symmetric and oval nucleus, width 3.28 +/- 0.20 mu m, length 4.75 +/- 0.20 mu m/absence of vacuoles occupying >4% of nuclear area) as well as acrosome, post-acrosomal lamina, neck and tail, besides not presenting cytoplasm around the head. One examiner, blinded to subject identity, performed the entire study.Results: Mean percentages of morphologically normal and LNV spermatozoa were identical in the two MSOME analyses (1.6 +/- 2.2% vs. 1.6 +/- 2.1% P = 0.83 and 25.2 +/- 19.2% vs. 26.1 +/- 19.0% P = 0.31, respectively). Regression analysis between the two samples revealed significant positive correlation for morphologically normal and for LNV spermatozoa (r = 0.57 95% CI: 0.47-0.65 P < 0.0001 and r = 0.50 95% CI: 0.38-0.58 P < 0.0001, respectively).Conclusions: The significant positive correlation and absence of differences between two sperm samples evaluated after a time interval with respect to normal morphology and LNV spermatozoa indicated that MSOME seems reliable (at least for these two specific sperm forms) for analyzing semen. The present result supports the future use of MSOME as a routine method for semen analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CLSI M100-S19 document has recommended the disuse of vancomycin disks for staphylococci and informed that studies on the action of teicoplanin in disk-diffusion testing should be performed. We describe the comparison of two methods, disk diffusion and broth microdilution, for determining teicoplanin susceptibility in clinical isolates of staphylococci. Overall results showed an aggregation rate of 96.8%; Staphylococcus aureus showed total agreement while S. epidermidis showed 93.8% of agreement. According to these local results, disk diffusion can still be employed to teicoplanin susceptibility determination for staphylococci in our institution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we determine a matrix S and a vector l for stiffly-stable Adams-type cyclic methods that are insensitive to step size changes by using the definition of equivalent methods, (see, e.g. [l]), in the Nordsieck notation. The elements S and l, written in a parametric form, permit us to represent in Nordsieck form the methods that were constructed in [7] and the new methods that satisfy the above properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to determine the reproducibility and validity of DIAGNOdent in detecting active and arrested caries lesions on free smooth surfaces. Volunteers were selected from state schools of Piracicaba, São Paulo, Brazil. Overall, 220 lesions were clinically examined. Two specially trained ('calibrated') examiners performed both clinical and laser evaluations independently, and after a 1-week interval, the examinations were repeated, the intra-examiner agreement for the laser evaluation was substantial (kappa(ex1) = 0.79, kappa(ex2) = 0.71). There was almost perfect agreement between the two examiners for the clinical examination (kappa(ex1) = 0.95, kappa(ex2) = 0.85). The inter-examiner agreement showed substantial reproducibility (kappa = 0.77) for the laser examination and almost perfect agreement (kappa = 0.85) for the clinical evaluation. The validation criterion was the clinical examination of white spots, recorded as active or arrested. The sensitivity was 0.72 and the specificity was 0.73, which indicates that the DIAGNOdent was a good auxiliary method for detecting incipient caries lesions on free smooth surfaces. The utilization of both methods can improve the efficacy of caries diagnosis. Copyright (C) 2002 S. Karger AG, Basel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

All methods to detect experimental loss of bone present technique limitations. The sensitivities of image and histological analyses to detect the effects of teriparatide in rats with bone loss after ovariectomy were evaluated. All methods were qualitatively valid.The standardization of methods to assess bone loss after ovariectomy is crucial to establish the degree of experimental osteoporosis. In general, methods per image or histological techniques are used. To validate these two ways to determine the degree of bone loss in ovariectomized rats, we evaluated the sensitivities of bone densitometry, conventional radiography, and histological analysis of the area occupied by collagen, detecting the effects of teriparatide treatment in the femur of ovariectomized rats with bone loss.Wistar rats were divided into three groups: a control group, in which the animals were only subjected to laparotomy; an ovariectomized group, in which bilateral removal of the ovaries was performed; and an ovariectomized + teriparatide group, in which bilateral removal of the ovaries was performed, and the animals were treated with 3 mu g/100 g/day of teriparatide. Three months following the ovariectomy, bone densitometry, radiographic densitometry, and histological analysis of the area occupied by collagen fibers were carried out in the femur diaphysis.The bone densitometry revealed 11.2% reduction in femur density; in the conventional radiography, the loss of bone mass was 14.5%, and with the histological analysis, a 40.9% reduction in the area occupied by collagen was detected in the femur diaphysis.In conclusion, histological analysis could not be quantitatively compared with the methods of bone densitometry and conventional radiography; however, all of these methods were qualitatively valid for assessing the loss of bone stemming from ovariectomy and the therapeutic effect of teriparatide in the prevention of osteoporosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper made an analysis of some numerical integration methods that can be used in electromagnetic transient simulations. Among the existing methods, we analyzed the trapezoidal integration method (or Heun formula), Simpson's Rule and Runge-Kutta. These methods were used in simulations of electromagnetic transients in power systems, resulting from switching operations and maneuvers that occur in transmission lines. Analyzed the characteristics such as accuracy, computation time and robustness of the methods of integration.