163 resultados para Using an harmonic instrument
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The study of algorithms for active vibration control in smart structures is an area of interest, mainly due to the demand for better performance of mechanical systems, such as aircraft and aerospace structures. Smart structures, formed using actuators and sensors, can improve the dynamic performance with the application of several kinds of controllers. This article describes the application of a technique based on linear matrix inequalities (LMI) to design an active control system. The positioning of the actuators, the design of a robust state feedback controller and the design of an observer are all achieved using LMI. The following are considered in the controller design: limited actuator input, bounded output (energy) and robustness to parametric uncertainties. Active vibration control of a flat plate is chosen as an application example. The model is identified using experimental data by an eigensystem realization algorithm (ERA) and the placement of the two piezoelectric actuators and single sensor is determined using a finite element model (FEM) and an optimization procedure. A robust controller for active damping is designed using an LMI framework, and a reduced model with observation and control spillover effects is implemented using a computer. The simulation results demonstrate the efficacy of the approach, and show that the control system increases the damping in some of the modes.
Resumo:
This paper investigates the feasibility of using an energy harvesting device tuned such that its natural frequency coincides with higher harmonics of the input to capture energy from walking or running human motion more efficiently. The paper starts by reviewing the concept of a linear resonant generator for a tonal frequency input and then derives an expression for the power harvested for an input with several harmonics. The amount of power harvested is estimated numerically using measured data from human subjects. Assuming that the input is periodic, the signal is reconstructed using a Fourier series before being used in the simulation. It is found that although the power output depends on the input frequency, the choice of tuning the natural frequency of the device to coincide with a particular higher harmonic is restricted by the amount of damping that is needed to maximize the amount of power harvested, as well as to comply with the size limit of the device. It is also found that it is not feasible to tune the device to match the first few harmonics when the size of the device is small, because a large amount of damping is required to limit the motion of the mass.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Diamond-like carbon (DLC) films were obtained by spinning a tungsten carbide substrate at a high speed using an oxyacetylene flame. The films deposited at a typical experimental condition of substrate temperature of 810 degrees C, rotation of 600 rpm and 3 h deposition time, exhibited an uniform, very smooth, hard and glassy surface covering the entire exposed face of the substrate. These films were identified as DLC by their characteristic broad Raman spectra centered at 1554 cm(-1) and micro-Vicker's hardness > 3400 kg mm(-2). For substrate temperatures < 800 degrees C the film started losing the uniform glassy surface and the hardness deteriorated. For temperatures > 950 degrees C the film was still hard and shiny, but black in color. DLC films were also obtained in a wide range of speeds of rotation (300-750 rpm), as long as the temperature remained close to 850 degrees C. (C) 1999 Elsevier B.V. S.A. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Microscopic evaluation of induced tooth movement in traumatized teeth: an experimental study in rats
Resumo:
The clinical management of orthodontic patients with dental trauma before or during the treatment is mainly founded on clinical experience, expert opinions, and individual case reports. It is proposed in the literature that teeth sustaining mild trauma with minor damage to the periodontium (e.g. subluxation) should be followed for a period of time before being subjected to orthodontic forces. A minimum period of 3 months has been proposed. In this study, we used an animal model to investigate whether shorter observation periods could be established in case of mild trauma. The periradicular region of rat molars was examined microscopically to determine the biological events of tooth movement started 15 and 30 days after intentional subluxation using an experimental method to induce dentoalveolar trauma. Thirty adult male Wistar rats were assigned to 6 groups (n = 5): Group 1 (control no trauma/orthodontic movement); Group 2: the animals received an orthodontic device and were sacrificed after 7 days; Groups 3 and 4: dentoalveolar trauma (subluxation) was experimentally induced by the application of an axial force of 900 cN on the occlusal surface of the maxillary right first molar, and the animals were sacrificed after 22 and 37 days, respectively; and Groups 5 and 6: 15 and 30 days, respectively, after force application, an orthodontic device was installed and the rats were sacrificed 7 days later. In G5 and G6, the periodontal ligament and pulp tissue were rich in cellular elements and blood vessels, the alveolar bone was preserved, and the root surface presented only very small areas of surface resorption (cementum), maintaining the characteristics of normality. In conclusion, the microscopic alterations in the gingival and periodontal tissues in response to an experimentally induced mild dentoalveolar trauma simulating subluxation were not sufficient to contraindicate starting the orthodontic movement 15 and 30 days after trauma.
Resumo:
This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.
Resumo:
Aims: This multi-centre analysis assessed the DNA content of TSCC in 37 young patients (<40 years) and 28 old patients (>50 years) and determined the correlation of DNA ploidy findings with clinicopathological data.Methods and results: Image cytometry was carried out using an automated cellular imaging system on Feulgen-stained histological sections to obtain high-fidelity DNA histograms. Among young patients, 37.8% were females compared to 18.7% in the older group (P = 0.002). In total, 48.6% patients were non-smokers and 40.5% were non-drinkers compared to 10.7% non-smokers and non-drinkers in the older group (P < 0.0001). TNM, clinical stage of disease and histological grade of differentiation did not differ between groups. Tumour aneuploidy was detected in 86.5% and tetraploidy in 24.3% young patients; this was significantly greater than in the older group where 64.3% were aneuploid (P < 0.0001) and 7.2% tetraploid (P < 0.0001). The mean values of DNA index (DI) and DNA heterogeneity index as well as the percentage of cells with DI exceeding 5N were higher in young patients (P < 0.0001).Conclusions: Young patients with TSCC represent a distinct clinical entity. The high incidence of DNA ploidy abnormalities suggest that they may have increased genomic instability and indicates underlying genetic differences between TSCC in young and older patients.
Resumo:
The purpose of this study was to investigate the histological changes that occur in rat soft and hard tissues after Er,Cr:YSGG laser surgery. Each of 20 rats was submitted to four procedures which were randomly distributed to the right and left sides of the animal: procedure 1 dorsal incision with a scalpel; procedure 2 dorsal incision with a 2.0-W Er,Cr:YSGG laser; procedure 3 skull defect created with a diamond bur; procedure 4 skull defect created with a 3.0-W Er,Cr:YSGG laser. The animals were killed 3, 7, 15 and 30 days after surgery, and histological examinations were performed. The histometric analysis of the bone defects was evaluated using an unpaired t-test. Initially, the dorsum showed more histological signs of repair following procedure 1, although similar healing responses following procedures 1 and 2 were seen on day 30 after surgery. By day 30 the bone formation observed following procedure 4 was much more evident than following procedure 3. The unpaired t-test identified significant differences in bone formation on day 30 (p = 0.01), whereas a greater bone percentage was seen following procedure 4 than following procedure 3 (79.96 +/- 10.30% and 58.23 +/- 9.99%, respectively). Thus, histological repair of the Er,Cr:YSGG laser wounds was similar to that of the scalpel wounds. However, skull defects created with the Er,Cr:YSGG laser showed greater bone formation than defects created with the bur. Within the limitations of this study, we can conclude that the Er,Cr:YSGG laser is a promising surgical instrument in vivo, particularly for bone surgery.
Construção coletiva de uma trilha ecológica no cerrado: pesquisa participativa em educação ambiental
Resumo:
Dentre os muitos temas ambientais que podem ser problematizados pela Educação Ambiental encontra-se a proteção aos ecossistemas. Definiu-se como tema, num projeto de Educação Ambiental, o Cerrado, bioma amplamente degradado por ações antrópicas e que faz parte do ambiente natural de Botucatu, interior de São Paulo. Com o objetivo de despertar um olhar crítico-ambiental, visando a integração do ambiente natural e urbano, o projeto, realizado com alunos da 8ª série do Ensino Fundamental, teve como eixo a construção de uma Trilha Ecológica no Cerrado. Todo o processo de planejamento, realização e avaliação da trilha foi participativo: os participantes estudaram as características do Cerrado; identificaram, na área, as espécies remanescentes; discutiram as condições de conservação da área, e tomaram decisões sobre a construção da trilha como recurso educativo. Problematizaram, coletivamente, a interação comunidade-ambiente, articulando consciência ambiental e ação educativa, concluindo sobre o potencial desencadeador deste recurso para reflexões sobre temas socioambientais. O grupo teve a oportunidade de vivenciar um trabalho educativo com crianças da educação infantil, concretizando a trilha como recurso didático-pedagógico na aproximação visitantes-educandos-ambiente.
Resumo:
The purpose of this study was to evaluate in vitro the efficacy of root reinforcements by light-cured composite resin or zirconium fiber post in simulated immature non-vital teeth. Fifty-six bovine incisors teeth were used for this study. The crown of each tooth was removed in the medium third to obtain a standard length of 30 mm. The specimens were divided into four groups (n = 14): G1) the root canals were instrumented and enlarged to simulate immature non-vital teeth and were reinforced with a light-cured composite resin using a translucent curing post (Luminex system); (G2) the specimens were instrumented, enlarged and they received root reinforcement with zirconium fiber post; G3 (positive control): they received similar treatment to the G1 and G2 groups, but did not receive root reinforcement; G4 (negative control): the roots were not weakened and did not receive reinforcement. Every tooth was submitted to compressive force using an Instron testing machine with an angle of 45&DEG; at a speed of 1 mm min(-1) until the fracture. The results showed a markedly increased resistance to fracture in the G1 and G2 (122.38 and 122.08 kgf, respectively). Among the results of G1 and G2 there was not any significant difference (P > 0.05) but they were significantly different from the control groups (P < 0.05). The conclusion is that the use of root reinforcements with zirconiun fiber post or composite resin can increase significantly the structural resistance of the weakened teeth, decreasing the risk of the fracture.
Resumo:
Objectives. This study characterized the feldspathic ceramic surfaces after various silanization protocols.Methods. Ceramic bars (2 mm x 4 mm x 10 mm) (N = 18) of feldpathic ceramic (VM7, VITA Zahnfabrik) were manufactured and finished. Before silane application, the specimens were ultrasonically cleaned in distilled water for 10 min. The ceramic specimens were randomly divided into nine groups (N = 2 per group) and were treated with different silane protocols. MPS silane (ESPE-Sil, 3M ESPE) was applied to all specimens and left to react at 20 degrees C for 2 min (G20). After drying, the specimens were subjected to heat treatment in an oven at 38 degrees C (G38), 79 degrees C (G79) or 100 degrees C (G100) for 1 min. Half of the specimens of each group were rinsed with water at 80 degrees C for 15 s (G20B, G38B, G79B, G100B). The control group (GC) received no silane. Attenuated total reflection infrared Fourier transform analysis (ATR FT-IR) was performed using a spectrometer. Thickness of silane layer was measured using a spectroscopic ellip-someter working in the lambda = 632.8 nm (He-Ne laser) at 70 degrees incidence angle. Surface roughness was evaluated using an optical profilometer. Specimens were further analyzed under the Scanning Electron Microscopy (SEM) to observe the topographic patterns.Results. ATR FT-IR analysis showed changes in Si-O peaks with enlarged bands around 940 cm(-1). Ellipsometry measurements showed that all post-heat treatment actions reduced the silane film thickness (30.8-33.5 nm) compared to G20 (40 nm). The groups submitted to rinsing in hot water (B groups) showed thinner silane films (9.8-14.4 nm) than those of their corresponding groups (without washing) (30.8-40 nm). Profilometer analysis showed that heat treatments (Ra approximate to 0.10-0.19 mu m; Rq approximate to 0.15-0.26 mu m) provided a smoother surface than the control group (Ra approximate to 0.48 mu m; Rq approximate to 0.65 mu m). Similar patterns were also observed in SEM images.Significance. Heat treatment after MPS silane application improved the silane layer network. Rinsing with boiling water eliminated the outmost unreacted regions of the silane yielding to thinner film thicknesses. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)