107 resultados para Infrared.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the nonlinear (NL) optical properties of glassy TeO2-GeO2-K2O-Bi2O3 at lambda = 800 nm and lambda = 1,064 nm. Using the Kerr gate technique with a laser delivering 150 fs pulses at 800 nm, we demonstrated the fast NL response of the samples. The modulus of the NL refractive index, n (2), at 800 nm was similar to 10(-15) cm(2)/W. The Z-scan technique was used to determine n (2) a parts per thousand +10(-15) cm(2)/W, at 1,064 nm with pulses of 17 ps. The two-photon absorption coefficient, alpha (2), was smaller than the minimum that we can measure (< 0.003 cm/GW). The figure of merit n (2)/alpha (2) lambda was calculated and indicates that this glass composition has large potential to be used for all-optical switching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SynopsisBackgroundCellulite refers to changes in skin relief on the thighs and buttocks of women, with a prevalence of 80-90%, causing dissatisfaction and search for treatment. Etiopathogenesis is multifactorial, as follows: herniation of the hypodermis towards the dermis, facilitated by perpendicular fibrous septa, changes in the dermal extracellular matrix, decreased adiponectin, genetic polymorphism, microcirculation alterations and inflammatory process. There are numerous therapeutic approaches, with little evidence of effectiveness. The long-wave infrared (LWIR) radiation interacts with water, improves microcirculation and stimulates metabolic processes. To date, the use of tissues with potential reflection of LWIR radiation has not been systematically investigated as adjuvant treatment for cellulite.ObjectiveTo investigate the efficacy and safety of the treatment of cellulite through the use of compression stockings made with thread reflecting LWIR radiation.Patients and methodsClinical study of therapeutic intervention, controlled and double-blind, including 30 women, aging from 25 to 40years, with cellulite of grades II and III on the thighs and buttocks who used compression stockings, pantyhose model, made with reflector thread of LWIR radiation, on only one randomized side. Women under other treatments for cellulite and with venous and/or blood insufficiencies were excluded. Evaluation of efficacy by clinical parameters, photographs, Dermatology Life Quality Index (DLQI), cutometry and high frequency ultrasonography and security by observation of adverse events and venous EcoDoppler recordings.ResultsDLQI scores showed significant reduction; the two-dimensional high-frequency ultrasonography showed an insignificant increase in dermal echogenicity as well as other efficacy parameters demonstrated no or slight improvement, with no differences between the sides exposed or not to LWIR; and there were no severe adverse events.ConclusionCompression stockings, with or without thread reflector of LWIR, showed slight effects in the appearance of cellulite, but the treatment determined a positive impact on women quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A possible way for increasing the cutting tool life can be achieved by heating the workpiece in order to diminish the shear stress of material and thus decrease the machining forces. In this study, quartz electrical resistances were set around the workpiece for heating it during the turning. In the tests, heat-resistant austenitic alloy steel was used, hardenable by precipitation, mainly used in combustion engine exhaustion valves, among other special applications for industry. The results showed that in the hot machining the cutting tool life can be increased by 340% for the highest cutting speed tested and had a reduction of 205% on workpiece surface roughness, accompanied by a force decrease in relation to conventional turning. In addition, the chips formed in hot turning exhibited a stronger tendency to continuous chip formation indicating less energy spent in material removal process. Microhardness tests performed in the workpieces subsurface layers at 5 m depth revealed slightly higher values in the hot machining than in conventional, showing a tendency toward the formation of compressive residual stress into plastically deformed layer. The hot turning also showed better performance than machining using cutting fluid. Since it is possible to avoid the use of cutting fluid, this machining method can be considered better for the environment and for the human health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate the supercontinuum (SC) generation in a suspended-core As2S3 chalcogenide microstructured optical fiber (MOF). The variation of SC is investigated by changing the fiber length, pump peak power and pump wavelength. In the case of long fibers (20 and 40 cm), the SC ranges are discontinuous and stop at the wavelengths shorter than 3500 nm, due to the absorption of fiber. In the case of short fibers (1.3 and 2.4 cm), the SC ranges are continuous and can extend to the wavelengths longer than 4 μm. The SC broadening is observed when the pump peak power increases from 0.24 to 1.32 kW at 2500 nm. The SC range increases with the pump wavelength changing from 2200 to 2600 nm, corresponding to the dispersion of As2S3 MOF from the normal to anomalous region. The SC generation is simulated by the generalized nonlinear Schrödinger equation. The simulation includes the SC difference between 1.3 and 2.4 cm long fiber by 2500 nm pumping, the variation of SC with pump peak power in 2.4 cm long fiber, and the variation of SC with pump wavelength in 1.3 cm long fiber. The simulation agrees well with the experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical study of As2S3 Raman fiber lasers is carried out to show their potential for the entire coverage of the 3–4-m spectral band. Experimental results are first obtained from such a laser operated under controlled conditions in order to set the fiber parameters (i.e., gain and attenuation coefficients) to be used in the numerical model. An exhaustive numerical analysis is then performed to establish the conditions for optimum lasing performances over the entire 3–4-m spectral band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first demonstration of mid-infrared supercontinuum generation in As2Se3 chalcogenide microwires with the added advantage of using low energy pulses. The generated SC covers two octaves of bandwidth from 1.1 µm to 4.4 µm at -30 dB. This exceeds the broadest reported SC bandwidth in As2Se3 microwires by a factor of 3.5. The microwire geometry and pumping conditions are the key parameters in generating the 3.3 µm bandwidth while using a low pump pulse energy of 500 pJ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on infrared supercontinuum (SC) generation through laser filamentation and subsequent nonlinear propagation in a step-index As2S3 fiber. The 100 μm core and high-purity As2S3 fiber used exhibit zero-dispersion wavelength around 4.5 μm, a mid-infrared background loss of 0.2dB/m, and a maximum loss of only 0.55dB/m at the S-H absorption peak around 4.05 μm. When pumping with ultrashort laser pulses slightly above the S-H absorption band, broadband infrared supercontinua were generated with a 20 dB spectral flatness spanning from 1.5 up to 7 μm. The efficiency and spectral shape of the SC produced by ultrashort pulses in large-core As2S3 fiber are mainly determined by its dispersion, the S-H contaminant absorption, and the mid-infrared nonlinear absorption.