157 resultados para INTERLABORATORY VALIDATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. From shotgun libraries used for the genomic sequencing of the phytopathogenic bacterium Xanthomonas axonopodis pv. citri (XAC), clones that were representative of the largest possible number of coding sequences (CDSs) were selected to create a DNA microarray platform on glass slides (XACarray). The creation of the XACarray allowed for the establishment of a tool that is capable of providing data for the analysis of global genome expression in this organism. Findings. The inserts from the selected clones were amplified by PCR with the universal oligonucleotide primers M13R and M13F. The obtained products were purified and fixed in duplicate on glass slides specific for use in DNA microarrays. The number of spots on the microarray totaled 6,144 and included 768 positive controls and 624 negative controls per slide. Validation of the platform was performed through hybridization of total DNA probes from XAC labeled with different fluorophores, Cy3 and Cy5. In this validation assay, 86% of all PCR products fixed on the glass slides were confirmed to present a hybridization signal greater than twice the standard deviation of the deviation of the global median signal-to-noise ration. Conclusions. Our validation of the XACArray platform using DNA-DNA hybridization revealed that it can be used to evaluate the expression of 2,365 individual CDSs from all major functional categories, which corresponds to 52.7% of the annotated CDSs of the XAC genome. As a proof of concept, we used this platform in a previously work to verify the absence of genomic regions that could not be detected by sequencing in related strains of Xanthomonas. © 2010 Moreira et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the number of simulation experiments increases, the necessity for validation and verification of these models demands special attention on the part of the simulation practitioners. By analyzing the current scientific literature, it is observed that the operational validation description presented in many papers does not agree on the importance designated to this process and about its applied techniques, subjective or objective. With the expectation of orienting professionals, researchers and students in simulation, this article aims to elaborate a practical guide through the compilation of statistical techniques in the operational validation of discrete simulation models. Finally, the guide's applicability was evaluated by using two study objects, which represent two manufacturing cells, one from the automobile industry and the other from a Brazilian tech company. For each application, the guide identified distinct steps, due to the different aspects that characterize the analyzed distributions. © 2011 Brazilian Operations Research Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical modeling of the interaction among waves and coastal structures is a challenge due to the many nonlinear phenomena involved, such as, wave propagation, wave transformation with water depth, interaction among incident and reflected waves, run-up / run-down and wave overtopping. Numerical models based on Lagrangian formulation, like SPH (Smoothed Particle Hydrodynamics), allow simulating complex free surface flows. The validation of these numerical models is essential, but comparing numerical results with experimental data is not an easy task. In the present paper, two SPH numerical models, SPHysics LNEC and SPH UNESP, are validated comparing the numerical results of waves interacting with a vertical breakwater, with data obtained in physical model tests made in one of the LNEC's flume. To achieve this validation, the experimental set-up is determined to be compatible with the Characteristics of the numerical models. Therefore, the flume dimensions are exactly the same for numerical and physical model and incident wave characteristics are identical, which allows determining the accuracy of the numerical models, particularly regarding two complex phenomena: wave-breaking and impact loads on the breakwater. It is shown that partial renormalization, i.e. renormalization applied only for particles near the structure, seems to be a promising compromise and an original method that allows simultaneously propagating waves, without diffusion, and modeling accurately the pressure field near the structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2010 QIAGEN® launched to eight kits of different combinations of STRs, including the Investigator IDplex Kit. This kit allows amplification in one PCR 16 markers. The aim of this study was to evaluate the reproducibility of Investigator IDplex Kit among Latin America laboratories. In the framework of the 'III International Theoretical-Practice Course in Populations Genetic and Biologicals Filiations' in Medellín-Colombia, all participants were invited to evaluate the reproducibility of this kit, they were provided of the necessary materials for the study. The results reported by participating were tabulated for the study the reproducibility. Results and comments were received on the agreed date of 12 of the 22 laboratories registered, one participant submits comments only. Some laboratories reported greater sensitivity Investigator IDplex Kit compared with other kits containing similar markers, also highlight the easy adaptability to existing conditions in laboratories, without involving major changes to its implementation. This paper shows the high reproducibility of Investigator IDplex Kit, a new tool offered by QIAGEN® for all laboratories that perform human identification testing and biological relationship testing using DNA markers. © 2011 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Latin-American Society of Forensic Genetics (SLAGF) Interlaboratory Quality Control Exercise (2010-2011) included the analysis of three bloodstain samples in FTA Classic Card (three persons, biologically unrelated) and one theoretical exercise. There were 56 participating laboratories from 13 Latin-American countries that belong to society, were reported 70 STRs, including autosomal and sex chromosome markers with consensus in 53 STRs with a rate in reporting errors of 2.3%. Fifty-six laboratories reported results in theoretical exercise with mistakes in calculation of IP for each marker. It is necessary to hold meetings to discuss the results of this exercise to reach conclusions and recommendations on all aspects of DNA forensics analysis and paternity test, to improve results and quality in the results of each laboratory. © 2011 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the objective to know the electromyographic activity normal parameters of the deltoid (anterior portion) and pectoralis major (clavicular portion) muscles in the different modalities of military press exercises with middle grip, we analyzed 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes. It was observed high inactivity levels for PMC in almost all the modalities and the concentration in the active cases, mainly, in the weak potential, while DA presented very high levels of much strong action potentials in all the modalities assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deltoid (anterior portion) and pectoralis major (clavicular portion) were evaluated in several execution ways of military press exercises with open and middle grips in order to know their behavior pattern. It was analyzed 24 male volunteers, using a 2-channel TECA TE4 electromyograph and Hewllet Packard surface electrodes. It was observed that the execution variation with open and middle grips does not present any significant difference as for the demanding level neither for the pectoralis major muscle nor the deltoid muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ceftriaxone sodium is a cephalosporin with broad-spectrum antimicrobial activity and belongs to the third generation of cephalosporins. Regarding the quality control of medicines, a validated microbiological assay for the determination of ceftriaxone sodium in powder for injectable solution has not been reported yet. This paper reports the development and validation of a simple, accurate and reproducible agar diffusion method to quantify ceftriaxone sodium in powder for injectable solution. The assay is based on the inhibitory effect of ceftriaxone sodium on the strain of Bacillus subtilis ATCC 9371 IAL 1027 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.999) in the selected range of 15.0-60.0 μg/mL, precise with a relative standard deviation (RSD) of repeatability intraday = 1.40%, accurate (100.46%) and robust with a RSD lower than 1.28%. The results demonstrated the validity of the proposed bioassay, which allows reliable ceftriaxone sodium quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2012 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objective: Simple Measure of the Impact of Lupus Erythematosus in Youngsters (SMILEY) is a health-related quality of life (HRQOL) assessment tool for pediatric systemic lupus erythematosus (SLE), which has been translated into Portuguese for Brazil. We are reporting preliminary data on cross-cultural validation and reliability of SMILEY in Portuguese (Brazil). Methods: In this multi-center cross-sectional study, Brazilian children and adolescents 5-18 years of age with SLE and parents participated. Children and parents completed child and parent reports of Portuguese SMILEY and Portuguese Pediatric Quality of Life Inventory (PedsQLTM) Generic and Rheumatology modules. Parents also completed the Childhood Health Assessment Questionnaire (CHAQ). Physicians completed the SLE disease activity index (SLEDAI), Physician's Global Assessment of disease activity (PGA) and Systemic Lupus Erythematosus International Collaborating Clinics ACR Damage Index (SDI). Results: 99 subjects (84 girls) were enrolled; 93 children and 97 parents filled out the SMILEY scale. Subjects found SMILEY relevant and easy to understand and completed SMILEY in 5-15 minutes. Brazilian SMILEY was found to have good psychometric properties (validity and reliability), and the child-parent agreement was moderate. Conclusion: SMILEY may eventually be used routinely as a research/clinical tool in Brazil. It may be also adapted for other Portuguese-speaking nations offering critical information regarding the effect of SLE on HRQOL for children with SLE. © The Author(s), 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.