111 resultados para Geophysical tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the first results of a system to carry out seismic SPT, which associates the up-hole seismic technique to the currently used SPT test. This hybrid test allows determining the maximum shear modulus (G 0) together with the SPT test. G 0 is the most important dynamic soil parameter and it is calculated based on the shear wave velocity (V S) measurements. The equipment and the method of analysis will be briefly described. The V s values measured using the S-SPT in one experimental research site located inland of Sao Paulo State-Brazil are presented and compared with down-hole and Seismic CPT test data. These preliminary results indicate that the S-SPT was satisfactory and can be used for dynamic site characterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The uplift capacity of helical piles depends on the shear resistance of the soil above the helical plates. During helical pile installation, the soil traversed by the plates are sheared and displaced laterally, and consequently the soil structure is disturbed. Considering this fact, the aim of this paper is presenting the effect of helical piles installation in the soil mass by means of CPT tests carried out close to the soil cylinder above the pile helices. The CPT tests were performed at the CRHEA site from the Sao Carlos School of Engineering, Sao Carlos city, inland of Sao Paulo State, Brazil. In addition, an interpretation of CPT tests data for stratigrafic logging are presented and compared to Standard Penetration Tests (SPT) carried out at this site. This study showed that the CPT sleeve friction fs data were affected by the installation of helical pile in this particular tropical soil site. © 2013 Taylor & Francis Group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of vaccines against canine visceral leishmaniasis (CVL) may provide a prophylactic barrier, but antibody response detected by standard diagnostic techniques may not separate vaccinated from naturally infected dogs. Moreover, anti-Leishmania antibody levels in vaccinated dogs may be detectable for months. Accordingly, the aim of the present study was to comparatively evaluate an in-house ELISA with three serological tests officially adopted by the Brazilian Ministry of Health for the diagnosis of CVL in dogs vaccinated with Leishmune®. A total of 18 mongrel dogs were submitted to a complete protocol of the vaccine, monitored and evaluated in 5 times (T0-T4) up to 180 days after T0. Twenty-one days after the first dose (T1), 50% of the dogs were seropositive by the in-house ELISA and 5.5% by IFAT, while by the official ELISA and DPP® CVL rapid test all dogs tested negative. At time T2, 42 days after of the first dose, 100%, 83.3%, 11.1%, and 5.5% of the dogs were seropositive by the in-house ELISA, IFAT, official ELISA kit and the DPP® CVL rapid test, respectively. Ninety days after the first dose (T3), 100%, 83.3%, 72.2% and 33.3% of the dogs were seropositive by the in-house ELISA, official ELISA kit, IFAT, and the DPP® CVL rapid test, respectively. Finally, at time T4, 88.8%, 33.3%, 11.1% and 5.5% of the dogs were seropositive by the in-house ELISA, official ELISA kit, DPP® CVL rapid test and IFAT, respectively. In conclusion, dogs vaccinated with Leishmune® cross-react by an in-house ELISA and by the three official Brazilian serological tests for the diagnosis of canine visceral leishmaniasis up to six months after the first vaccine dose, and may be mistakenly diagnosed and removed. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parametric VaR (Value-at-Risk) is widely used due to its simplicity and easy calculation. However, the normality assumption, often used in the estimation of the parametric VaR, does not provide satisfactory estimates for risk exposure. Therefore, this study suggests a method for computing the parametric VaR based on goodness-of-fit tests using the empirical distribution function (EDF) for extreme returns, and compares the feasibility of this method for the banking sector in an emerging market and in a developed one. The paper also discusses possible theoretical contributions in related fields like enterprise risk management (ERM). © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the serological cross-reactivity between Leishmania sp. and other canine pathogens. Methods: Positive serum samples for Ehrlichia canis, Babesia canis, Toxoplasma gondii, Neospora caninum and Trypanosoma cruzi were tested using three serological methods enzyme linked immunosorbent assay (ELISA), indirect immunofluorescent antibody test (IFAT) and Kalazar Detect™, for canine visceral leishmaniasis. Results: Of the 57 dog samples tested, 24 (42.1%) tested positive using one of the three serological methods: 10/57 (17.5%) for ELISA, 11/57 (19.3%) for IFAT and 3/57 (5.3%) for Kalazar Detect™. Conclusions: Our results demonstrated that the presence of other infectious agents may lead to cross-reactivity on leishmaniasis serological tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mice experimentally infected with a pathogenic strain of Leptospira interrogans serovar Canicola produced false negative results (prozone effect) in a microscopic agglutination test (MAT). This prozone effect occurred in several serum samples collected at different post-infection times, but it was more prominent in samples collected from seven-42 days post-infection and for 1:50 and 1:100 sample dilutions. This phenomenon was correlated with increased antibody titres in the early post-infection phase. While prozone effects are often observed in serological agglutination assays for the diagnosis of animal brucellosis and human syphilis, they are not widely reported in leptospirosis MATs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major aspect in geosynthetics creep analysis is the load level applied to the specimen, usually referred as a percentage of the geosynthetic ultimate tensile strength (UTS). Since both tensile and creep standard tests are performed with in-isolation specimens, they may not reproduce the possibly significant effect of soil-geosynthetic interaction. A new creep testing machine was recently developed and successfully addressed this concern. However, further developments allowed tensile tests to be performed in the same conditions used in nonconventional creep ones. This paper presents the results of nonconventional tensile tests performed with a woven biaxial polyester geogrid. They were used to define its UTS in the same conditions employed in creep tests performed with the new equipment. Despite changes in tensile curves shapes were found, the UTS from confined, accelerated and confined-accelerated tensile tests were quite similar to those obtained with standard tensile test procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geophysical methods are widely used in mineral exploration. This paper discusses the results of geological and geophysical studies in supergene manganese deposits of southern Brazil. Mineralized zones as described in geological surveys were characterized as of low resistivity (20 Omega.m) and high chargeability (30ms), pattern found also in oxides and sulfite mineral deposits. Pseudo-3D modeling of geophysical data allowed mapping at several depths. A relationship between high chargeability and low resistivity may define a pattern for high grade gonditic manganese ore. Large areas of high chargeability and high resistivity may result in accumulation of manganese and iron hydroxides, due to weathering of the gonditic ore, dissolution, percolation and precipitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)