98 resultados para tomografia variazione totale norma L1 minimo alternato
Resumo:
Este trabalho pretende demonstrar que o processo de aquisição da linguagem culta está correlacionado a fatores de natureza extralingilistica como nível socioeconómico, idade e escolaridade.
Resumo:
This paper intends to present a selection of the most useful reading strategies for the typical ESP students in Brazilian universities, showing whether the readers use them in their native language or not, the way the teacher should develop these strategies in the classroom, the problems involved in their use and the reasons for using them.
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
The implementation of local geodetic networks for georeferencing of rural properties has become a requirement after publication of the Georeferencing Technical Standard by INCRA. According to this standard, the maximum distance of baselines to GNSS L1 receivers is of 20 km. Besides the length of the baseline, the geometry and the number of geodetic control stations are other factors to be considered in the implementation of geodetic networks. Thus, this research aimed to examine the influence of baseline lengths higher than the regulated limit of 20 km, the geometry and the number of control stations on quality of local geodetic networks for georeferencing, and also to demonstrate the importance of using specific tests to evaluate the solution of ambiguities and on the quality of the adjustment. The results indicated that the increasing number of control stations has improved the quality of the network, the geometry has not influenced on the quality and the baseline length has influenced on the quality; however, lengths higher than 20 km has not interrupted the implementation, with GPS L1 receiver, of the local geodetic network for the purpose of georeferencing. Also, the use of different statistical tests, both for the evaluation of the resolution of ambiguities and for the adjustment, have enabled greater clearness in analyzing the results, which allow that unsuitable observations may be eliminated.
Resumo:
This research presents the results of a cephalometric radiography study, in frontal norm, that was used to measure the possible linear correlations between several linear dimensions of the face, in a sample of a 140 caucasian brazilians, with an average age of 20 years, who were distributed in 2 groups as follows: Control group - formed of 35 males and 35 females, with no apparent facial deformities and with dental oclusion, not necessarily, in Angle's Class I; Unilateral cleft lip and palate group - formed of 35 males and 35 females with surgical correction of the up in the first year and of the palate until the third year of life, without orthodontic treatment. ln each teleradiography, the following parameters were measured using a computer: - Lateral orbit width or external orbit width (LOe) - Medial orbit width or internal orbit width (LOI) - Zygomatic width or facial width (LZI) - Mastold width (LMa) - Maxilar width (LMx) - Nasal width (LNa) - Condilar width (LCo) - Antigonial width (LGa) The values obtained were treated statistically using quantitative analysis (arithmetic mean, standard deviation, standard mean error, Person's variation factor and Pearson factor linear correlation). Theirs significance was established by Student's t test. The Pearson factor linear correlations determined between transverse linear cephalometric width dimensions of face in frontal norm for individuals of both groups and sex, with an average age of 20 years, were: ...
Resumo:
Considered the step that constitutes the intellectual work of the indexer, the approach runs the focus of the initial phase of the indexing process - the subject analysis. Among the various denominations that can be achieved, the subject analysis reaches its dimension applied when observed the rules that underlie the indexing process. The release of the documentary information requires the development of contributions to aid in the procedures of analysis, synthesis and representation of the contents documentary, seeking contributions to both the theoretical sedimentation, and for fostering the professional practice of the librarian. Through bibliographic exploratory research, this article aims to contribute to the relevance of subject analysis, concluding that there is a gap in the use of NBR 12676/1992, as well as the need for its updating.
Resumo:
Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i
Resumo:
The aim of this study is to perform a situational analysis of the Laboratory of pulp and paper-UNESP ITAPEVA for conducting proposal the accreditation according to ISO / IEC 17025:2005. The ISO / IEC 17025 establishes the criteria for those laboratories wishing to demonstrate their technical competence, which have an effective quality system and are able to generate technically valid results, establishing a single international standard for certifying the competence of laboratories to carry tests and / or calibrations, including sampling. The case study was conducted on laboratory Pulp and Paper Universidade Estadual Paulista (UNESP), campus Itapeva, where we compared the views of the technician responsible for the laboratory and a regular user. The generated conclusion is that the laboratory is unable to initiate an accreditation process, because it fails the requirements such as quality manual, register of subcontractors, research of customer satisfaction, schedule of internal audits, schedule for completion of critical analysis, profile of the functions required, functions current description, documentation of technical requirements for accommodation and environmental conditions, calibration programs, equipment calibration program, programs calibration standards and reports and / or certificate of test and / or calibration, that are in accordance with ISO / IEC 17025:2005, beyond that there is not the possibility to develop and implement a quality system without the commitment of everyone involved, regardless of the functional hierarchy
Resumo:
This paper proposes a reflection on processes of variation and change that occurred with the portuguese prepositions a, ate, em and para, taken as a parameter for answers in a broader context, the confrontation between the norm and use and between standard and linguistic variation. We conducted the study based on a corpus composed of all occurrences of the prepositions in question removed news of the newspaper O Combate and O Estado de Sao Paulo. Whereas the main objective of the study is to present and describe the use of these particles in newspaper articles of the Imprensa Paulista, data were collected and quantified by using the statistical package GOLDVARB, and interpretation of results relied (i) assumptions regarding the process variation in the use of prepositions and prepositions replace weak, as the preposition to, for strong prepositions (para, em, até), (ii) in comparison with the grammatical rule in effect at the time, (iii) and in the search for the existence of some historical factor that justifies the selection of a preposition rather than another. Among the hypotheses, we investigate the relationship between these prepositions and whose kind of preachers they introduce supplements: the direction of motion (abstract or concrete) or transfer (material and verbal / perceptual). This theoretical perspective was the Labovian sociolinguistics (Labov, 1972, 1994), which defines the linguistic variable as a representation of two or more different ways to convey a certain information content, being necessary to define it the following criteria set exact number of variants to establish all the multiplicity of contexts in which it appears; develop a quantitative index for measuring the values of variables
Resumo:
Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected
Resumo:
The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)
Resumo:
The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...
Resumo:
Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country