78 resultados para thermal protection systems


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A methodology for analyzing the solar access and its influence on both air temperature and thermal comfort of the urban environment was here developed by applying the potentiality of GIS tools. Urban canyons in a specific area of a Brazilian medium sized city were studied. First, a computational algorithm was applied in order to allow the determination of sky view factors (SVF) and sun-paths in urban canyons. Then, air temperatures in 40 measurement points were collected within the study area. Solar radiation values of these canyons were determined and subsequently stored in a GIS database. The creation of thermal maps for the whole neighbourhood was possible due to a statistical treatment of the data, by promoting the interpolation of values. All data could then be spatially cross-examined. In addition, thermal comfort maps for summer and winter periods were generated. The methodology allowed the identification of thermal tendencies within the neighbourhood, what can be useful in the conception of guidelines for urban planning purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ArcTech is a software being developed, applied and improved with the aim of becoming an efficient sensitization tool to support the teaching-learning process of Architecture courses. The application deals initially with the thermal comfort of buildings. The output generated by the software shows if a student is able to produce a pleasant environment, in terms of thermal sensation along a 24-hours period. Although one can find the very same characteristics in fully-developed commercial software, the reason to create ArcTech is related to the flexibility of the system to be adapted by the instructor and also to the need of simple tools for the evaluation of specific topics along the courses. The first part of ArcTech is dedicated to data management and that was developed using the visual programming language Delphi 7 and Firebird as the database management system. The second part contains the parameters that can be changed by the system administrator and those related to project visualization. The interface of the system, in which the student will learn how to implement and to evaluate the project alternatives, was built using Macromedia Flash. The software was applied to undergraduate students revealing its easy-learning and easy-teaching interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated three surface treatments and their effects on the shear bond strength between a resin cement and one of three ceramics. The ceramic surfaces were evaluated with scanning electron microscopy (SEM ) as well. Specimens were treated with 50 μm aluminum oxide airborne particles, 10% hydrofluoric acid etching, or a combination of the two. Using a matrix with a center hole (5.0 mm × 3.0 mm), the ceramic bonding areas were filled with resin cement following treatment. The specimens were submitted to thermal cycling (1,000 cycles) and the shear bond strength was tested (0.5 mm/minute). The failure mode and the effect of surface treatment were analyzed under SEM . Data were submitted to ANOVA and a Tukey test (α = 0.05). Duceram Plus and IPS Empress 2 composite specimens produced similar shear bond strength results (p > 0.05), regardless of the treatment method used. Hydrofluoric acid decreased the shear bond strength of In-Ceram Alumina specimens. For all materials, surface treatments changed the morphological surface. All treatments influenced the shear bond strength and failure mode of the ceramic/resin cement composites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The propulsion of most of the operating satellites comprises monopropellant (hydrazine - N2H4) or bipropellant (monometilydrazine - MMH and nitrogen tetroxide) chemical systems. When some sample of the propellant tested fails, the entire sample lot shall be rejected, and this action has turned into a health problem due to the high toxicity of N2H 4. Thus, it is interesting to know hydrazine thermal behavior in several storage conditions. The kinetic parameters for thermal decomposition of hydrazine in oxygen and nitrogen atmospheres were determined by Capela-Ribeiro nonlinear isoconversional method. From TG data at heating rates of 5, 10, and 20 C min-1, kinetic parameters could be determined in nitrogen (E = 47.3 ± 3.1 kJ mol-1, lnA = 14.2 ± 0.9 and T b = 69 C) and oxygen (E = 64.9 ± 8.6 kJ mol-1, lnA = 20.7 ± 3.1 and T b = 75 C) atmospheres. It was not possible to identify a specific kinetic model for hydrazine thermal decomposition due to high heterogeneity in reaction; however, experimental f(α)g(α) master-plot curves were closed to F 1/3 model. © 2013 Akadémiai Kiadó, Budapest, Hungary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we study two different spin-boson models. Such models are generalizations of the Dicke model, it means they describe systems of N identical two-level atoms coupled to a single-mode quantized bosonic field, assuming the rotating wave approximation. In the first model, we consider the wavelength of the bosonic field to be of the order of the linear dimension of the material composed of the atoms, therefore we consider the spatial sinusoidal form of the bosonic field. The second model is the Thompson model, where we consider the presence of phonons in the material composed of the atoms. We study finite temperature properties of the models using the path integral approach and functional methods. In the thermodynamic limit, N→∞, the systems exhibit phase transitions from normal to superradiant phase at some critical values of temperature and coupling constant. We find the asymptotic behavior of the partition functions and the collective spectrums of the systems in the normal and the superradiant phases. We observe that the collective spectrums have zero energy values in the superradiant phases, corresponding to the Goldstone mode associated to the continuous symmetry breaking of the models. Our analysis and results are valid in the limit of zero temperature β→∞, where the models exhibit quantum phase transitions. © 2013 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have compared the results of the external irrigation technique with those of a double irrigation technique with continuous intermittent movement. Maximum thermal measurements were made in the cortical part of 10 samples of bovine ribs during osteotomy to simulate the preparation of a surgical bed for the installation of dental implants at a depth of 10 mm Twenty specimens were drilled for each group: external irrigation and continuous movement (control group 1, CG1); external irrigation and intermittent movement (control group 2, CG2); double irrigation and continuous movement (test group 1, TG1); and double irrigation and intermittent movement (test group 2, TG2). The double irrigation technique gave significantly better results regardless of the drilling movement used. Thermal increases between samples was 19.2% in group CG1, 10.4% in CG2, 5.4% in TG1, and 3.4% in TG2. The double irrigation technique produced a significantly smaller increase in temperature in the cortical bone during both types of drilling (p = 0.001), which illustrated its greater efficiency compared with that of the external irrigation technique. (C) 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In general, the studies of finite size effects in mesoscopic superconductors have been carried out in such a way that the temperature parameter is constant in the entire system. However, we could have situations where a real sample is near a heater source, as an example. In such situations, gradients of temperature are present. On the other hand, mesoscopic superconductors are interesting systems due to the fact that they present confinement effects which influence all the vortex dynamics. Thus, in this work we studied the influence of thermal gradients on the vortex dynamics in mesoscopic superconductors. For this purposes, we used the time dependent Ginzburg-Landau equations. The thermal gradients produce an asymmetric distribution of the currents around the system which, in turn, yield interesting vortex configurations and difficult the formation of giant vortices.