92 resultados para respiratory tract cancer


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Doenças Tropicais - FMB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to estimate the association between exposure to particulate matter less than 2.5 microns in diameter and hospitalization for respiratory diseases. It was an ecological time series study with daily indicators of hospitalization for respiratory diseases in children up to 10 years, living in Piracicaba, SP, Southeastern Brazil, between August 1, 2011 and July 31, 2012. We used generalized additive model for the Poisson regression. The relative risks were RR = 1.008; 95%CI 1.001; 1.016 for lag 1 and RR = 1.009; 95%CI 1.001; 1.017 for lag 3. The increment of 10 mu g/m(3) in particulate matter less than 2.5 microns in diameter implies increase in relative risk between 7.9 and 8.6 percentage points. In conclusion, exposure to particulate matter less than 2.5 microns in diameter was associated with hospitalization for respiratory diseases in children.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chronic obstructive pulmonary disease (COPD) is characterized by progressive airway obstruction resultant from an augmented inflammatory response of the respiratory tract to noxious particles and gases. Previous reports present a number of different hypotheses about the etiology and pathophysiology of COPD. The generating mechanisms of the disease are subject of much speculation, and a series of questions and controversies among experts still remain. In this context, several experimental models have been proposed in order to broaden the knowledge on the pathophysiological characteristics of the disease, as well as the search for new therapeutic approaches for acute or chronically injured lung tissue. This review aims to present the main experimental models of COPD, more specifically emphysema, as well as to describe the main characteristics, advantages, disadvantages, possibilities of application, and potential contribution of each of these models for the knowledge on the pathophysiological aspects and to test new treatment options for obstructive lung diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Respiratory syncytial virus is the major cause of acute lower respiratory tract illness in infants and young children. Because there is currently no licensed vaccine for RSV, there is a substantial interest in the identification and development of RSV specific inhibitory agents. There are clinical evidences that glycosaminoglycans (GAGs) are potential inhibitors of viral infection. In this study, the performance of two GAGs (heparin and dextran sulfate) were compared for their antiviral and virucidal activities on RSV. Analysis was performed using an in vitro infection model where, previously to infection, Hep-2 cells or RSV were incubated with heparin or dextran sulfate. The presence of viral particles was analyzed by Reverse Transcriptase-Polimerase Chain Reaction (RT-PCR) and indirect immunofluorescence assays (IFA). The results showed that viral infection was more efficiently inhibited when Hep-2 cells were pre-incubated with heparin or, when viral particles were pre-incubated with dextran sulfate. Our study suggest that, in the absence of cellular death, heparin and dextran sulfate reduce RSV infection by different mechanisms, antiviral and virucidal ones, respectively. These data contribute for recent medical, microbiology and biochemical studies which suggest that the use of antiviral and virucidal compounds as more effective treatment to control virus infections.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes the in vivo Bronchoalveolar lavage (BAL)technique by endoscopy in tapirs (Tapirus terrestris) with clinicalsigns of tuberculosis. The technique was performed in two tapirs, male and female,from Curitiba Zoo, Paraná, Brazil. A flexible endoscope and a polyethylene catheterwere used after the chemical restraint of the animals. For BAL technique, 60mL ofsaline 0.9% were infused with a polyethylene catheter, introduced by the endoscope'working channel, and 15mL of BAL were recovered, analyzed and submitted tocytocentrifugation. Slides were stained by Papanicolaou, periodic acid-Schiff (PAS)and Ziehl-Neelsen methods contained high quantity of inflammatory cells on lightmicroscopy (macrophages 27.5%, lymphocytes 0.5%, neutrophis 67% and eosinophis 5%).BAL samples were submitted to culture, bacilloscopy and PCR and were negative forboth animals. Based on this study, it was concluded that the bronchoalveolar lavagetechnique in tapirs is feasible, simple, noninvasive, practical and fast, providingan important clinical information in vivo regarding the functionalstatus of the lower respiratory tract.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chronic obstructive pulmonary disease (COPD) is associated with autonomic dysfunctions that can be evaluated through heart rate variability (HRV). Resistance training promotes improvement in autonomic modulation; however, studies that evaluate this scenario using geometric indices, which include nonlinear evaluation, thus providing more accurate information for physiological interpretation of HRV, are unknown. This study aimed to investigate the influence of resistance training on autonomic modulation, using geometric indices of HRV, and peripheral muscle strength in individuals with COPD. Fourteen volunteers with COPD were submitted to resistance training consisting of 24 sessions lasting 60 min each, with a frequency of three times a week. The intensity was determined as 60% of one maximum repetition and was progressively increased until 80% for the upper and lower limbs. The HRV and dynamometry were performed at two moments, the beginning and the end of the experimental protocol. Significant increases were observed in the RRtri (4·81 ± 1·60 versus 6·55 ± 2·69, P = 0·033), TINN (65·36 ± 35·49 versus 101·07 ± 63·34, P = 0·028), SD1 (7·48 ± 3·17 versus 11·04 ± 6·45, P = 0·038) and SD2 (22·30 ± 8·56 versus 32·92 ± 18·78, P = 0·022) indices after the resistance training. Visual analysis of the Poincare plot demonstrated greater dispersion beat-to-beat and in the long-term interval between consecutive heart beats. Regarding muscle strength, there was a significant increase in the shoulder abduction and knee flexion. In conclusion, geometric indices of HRV can predict improvement in autonomic modulation after resistance training in individuals with COPD; improvement in peripheral muscle strength in patients with COPD was also observed.