212 resultados para palatal obturator
Resumo:
The effectiveness of microwave disinfection of maxillary complete dentures on the treatment of Candida-related denture stomatitis was evaluated. Patients (n = 60) were randomly assigned to one of four treatment groups of 15 subjects each; Control group: patients performed the routine denture care; Mw group: patients had their upper denture microwaved (650 W per 6 min) three times per week for 30 days; group MwMz: patients received the treatment of Mw group in conjunction with topical application of miconazole three times per day for 30 days; group Mz: patients received the antifungal therapy of group MwMz. Cytological smears and mycological cultures were taken from the dentures and the palates of all patients before treatment at day 15 and 30 of treatment and at follow-up (days 60 and 90). The effectiveness of the treatments was evaluated by Kruskal-Wallis and Mann-Whitney tests. Microbial and clinical analysis of the control group demonstrated no significant decrease in the candidal infection over the clinical trial. Smears and cultures of palates and dentures of the groups Mw and MwMz exhibited absence of Candida at day 15 and 30 of treatment. on day 60 and 90, few mycelial forms were observed on 11 denture smears (36.6%) from groups Mw and MwMz, but not on the palatal smears. Miconazole (group Mz) neither caused significant reduction of palatal inflammation nor eradicated Candida from the dentures and palates. Microwaving dentures was effective for the treatment of denture stomatitis. The recurrence of Candida on microwaved dentures at follow-up was dramatically reduced.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The mitogen-activated protein (MAP) kinase phosphatase (MKP) family plays an important function in regulating the pro-inflammatory cytokines by deactivating MAP kinases. MKP-1 is essential for the dephosphorylation of p38 MAP kinase that regulates expression of IL-6, TNF-alpha, and IL-1 beta. We hypothesized that MKP-1 regulates inflammatory bone loss in experimental periodontitis. Wild-type and Mkp-1(-/-) mice received A. actinomycetemcomitans LPS injection in the palatal region or PBS control 3 times/wk for 30 days. Mice were killed, and maxillae were assessed by microcomputed tomography, histological analysis, and TRAP staining for measurement of bone loss, extent of inflammation, and degree of osteoclastogenesis. Results indicated that, in LPS-injected Mkp-1(-/-) mice, significantly greater bone loss occurred with more inflammatory infiltrate and a significant increase in osteoclastogenesis compared with Mkp-1(-/-) control sites or either wild-type group. Analysis of these data indicates that MKP-1 plays a key role in the regulation of inflammatory bone loss.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Microwave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated.The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and a conventional heat-polymerised denture base resin (Lucitone 550-L).Specimens (10 mm x 20 mm x 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37 degrees C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37 degrees C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification x 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal-Wallis tests.MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection.Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10x), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Microsc. Res. Tech. 75:12331236, 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Caesalpinia echinata and C ferrea var. ferrea have different seed behaviours and seed and fruit types. Comparison of the seed ontogeny and anatomy partly explained the differences in seed behaviour between these two species of Brazilian legumes; some differences were also related to fruit development. The seed coat in C. ferrea consisted of two layers of osteosclereids, as well as macrosclereids and fibres, to form a typical legume seed coat, whereas C. echinata had only macrosclereids and fibres. In C. echinata, the developing seed coat had paracytic stomata, a feature rarely found in legume seeds. These seed coat features may account for the low longevity of C. echinata seeds. The embryogeny was similar in both species, with no differences in the relationship between embryo growth and seed growth. The seeds of both species behaved as typical endospermic seeds, despite their different morphological classification (exendospermic orthodox seeds were described for C. echinata and endospermic orthodox seeds for C. ferrea). Embryo growth in C. ferrea accelerated when the sclerenchyma of the pericarp was developing, whereas embryonic growth in C. echinata was associated with the conclusion of spine and secretory reservoir development in the pericarp. Other features observed included an endothelial layer that secreted mucilage in both species, a nucellar summit, which grew up into the micropyle, and a placental obturator that connected the ovarian tissue to the ovule in C. ferrea. (C) 2004 the Linnean Society of London.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: The present study evaluated morphometrically bone loss percentages in experimental periodontitis in rats, comparing different locations (lingual mandible, palatal maxilla and buccal maxilla) and two evaluation methods (distance and area methods). Material and Methods: Ligatures were placed around the maxillary right second molar and around the mandibular right first molar in 14 female Wistar rats. The contralateral molars served as intragroup control. After 4 weeks, the rats were sacrificed and their mandible and maxilla were removed. The specimens were dissected and stained with methylene blue dye. Bone loss was evaluated by two different methods on the surfaces of the defleshed jaw. In the first method, the distance from the cementoenamel junction (CEJ) to the alveolar bone crest was measured in the roots of teeth associated with ligature. In the second method, the area of bone loss was determined using the alveolar tissue bone, CEJ and the proximal region of roots associated with the ligature as reference. The data were converted to bone loss percentages caused by ligature: (ligated - unligated) x 100/ligated. Results: When comparing the distance and area methods, no statistically significant difference was observed (p>0.05). Both methodologies indicated that the maxilla presented greater bone loss than the mandible and it was more accentuated on the buccal side than on the palatal side (p<0.05). Conclusions: The findings of this study show that both the area and the distance methods can be used to evaluate bone loss caused by ligature placement in rats, and suggest applying the morphometric methodology to the maxilla on the buccal side.
Resumo:
Secondary caries is the main cause of direct restoration replacement. The purpose of this study was to analyze enamel adjacent to different restorative materials after in situ cariogenic challenge using polarized-light microscopy (PLM), scanning electron microscopy (SEM) and energy-dispersive X-ray analysis (EDS). Twelve volunteers, with a low level of dental plaque, a low level of mutans streptococci, and normal salivary flow, wore removable palatal acrylic appliances containing enamel specimens restored with Z250 composite, Freedom composite, Fuji IX glass-ionomer cement, or Vitremer resin-modified glass-ionomer for 14 days. Volunteers dripped one drop of 20% sucrose solution (n = 10) or distilled water (control group) onto each specimen 8 times per day. Specimens were removed from the appliances and submitted to PLM for examination of the lesion area (in mm(2)), followed by dehydration, gold-sputtering, and submission to SEM and EDS. The calcium (Ca) and phosphorus (P) contents were evaluated in weight per cent (%wt). Differences were found between Z250 and Vitremer, and between Z250 and FujiIX, when analyzed using PLM. Energy-dispersive X-ray analysis results showed differences between the studied materials regarding Ca %wt. In conclusion, enamel adjacent to glass-ionomer cement presented a higher Ca %wt, but this material did not completely prevent enamel secondary caries under in situ cariogenic challenge.
Resumo:
OBJECTIVE: The present prospective clinical study was designed in order to evaluate horizontal and vertical skeletal alterations induced by the use of Herbst appliance in individuals with Class II, division 1 malocclusion during mixed dentition stage. METHODS: The sampling consisted of 15 pre-pubertal individuals (12 boys and 3 girls; initial age 9 years and 6 months), who were treated with Herbst appliance for a period of 7 months. The effects of the treatment were compared to a group of 15 individuals with Class II, division 1 malocclusion (8 boys and 7 girls, initial age averaged 9 years and 1 month), orthodontically untreated, who were followed up for a period of 12 months. Statistical analysis was performed with Student's t-test with significance level at 5%. RESULTS: It was showed that the treatment with Herbst appliance in mixed dentition stage has restricted maxilla growth. Mandibular and palatal planes have not undergone significant alteration; however, anterior and posterior facial heights have increased significantly. Facial convexity and maxillomandibular relationship were altered positively. Mandible has positioned significantly forward and its effective length increased 2.5 times more than the increase observed in control group. CONCLUSION: It was possible to conclude that Herbst appliance was able to provide satisfactory results in individuals during mixed dentition stage.