110 resultados para energy balance


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study aimed to evaluate energy indicators of a new production system of yellow passion fruit in Marilia-SP. Analyzed the inputs of the biological energy, fossil and industrial and output energy in the form of fruits produced per unit area as well as five energy indicators. The input energy amounted 155,810.13MJ ha(-1). Chemical fertilizers and pesticides accounted for 71% and 24% of indirect energy industry, respectively. The activity generated per cycle / ha, 587.700.00MJ, and cultural productivity 0.19MJ kg(-1). The efficiency culture was 3.77. The cultural energy net totaled 431,889.87MJ ha(-1). The energy efficiency (4.17) and energy balance (550,312.91MJ ha(-1)) was favorable. It was concluded that the direct energy consumption from fossil fuels, even though significant, yet permits the production of the fruit of an environmentally sustainable manner. Chemical fertilizers and pesticides were the most representative of indirect energy industry due to the intensification of fertilization as a means of disease prevention.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The length of the post-partum anoestrous interval affects reproductive efficiency in many tropical beef cattle herds. In this study, results from genome-wide association studies (Experiment 1: GWAS) and gene expression (Experiment 2: microarray) were combined in a systems approach to reveal genetic markers, genes and pathways underlying the physiology of post-partum anoestrus in tropically adapted cattle. The microarray study measured the expression of 13,964 genes in the hypothalamus of Brahman cows. A total of 366 genes were differentially expressed (DE) in the post-partum period, when acyclic cows were compared to cows that had resumed ovarian cycles. Associated markers (P < 0.05) from a high density GWAS pointed to 2829 genes that were associated with post-partum anoestrous interval (PPAI) in two populations of beef cattle: Brahman and Tropical composite. Together the experiments provided evidence for 63 genes that are likely to influence the resumption of ovulation post-partum in tropically adapted beef cattle. Functional annotation analysis revealed that some of the 63 genes have known roles in hormonal activity, energy balance and neuronal synapse plasticity. Polymorphisms within candidate genes identified by this systems approach could have biological significance in post-partum anoestrus and help select Zebu (Bos indicus) influenced cattle with genetic potential for shorter post-partum anoestrus. Crown Copyright (C) 2014 Published by Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is known that the urban environment modifies the energy balance between the surface and the atmosphere, causing changes in temperature, relative humidity, among other things, opening the way for studies aimed at urban climatology. Based on the theme of urban climate, this research focuses on the city of Assis, located west of São Paulo. The generation of urban climate is a result of various factors, among which stand out: the use and different land use, the thermodynamic properties of buildings, number of buildings in the urban, socioeconomic activities, etc.. In general, this increases the temperature and reducing relative humidity, providing thermal discomfort. The rural environment is used for comparison studies to this theme by presenting different characteristics in relation to the structure, morphology and urban functionality. The main objective of this study is to determine the characteristics of temperature and humidity environments with the habits and occupations of the different soils in winter, at night, one inserted into the urban fabric of Assis and the other in the rural environment, to verify for evidence of changes in climatic elements because of urbanization. To collect the data will be used mini automatic weather stations that record data on temperature and humidity. For analysis of the results will be made between the data obtained in the city and the countryside, developing graphics application using Excel to tabulate the data. It was found that there were differences in the thermo-hygrometric data collection points, showing a specific urban climate in the city of Assis

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ethanol, the main automotive biofuel, has its production based on the fermentation of sugars found in biological materials and on the distillation of the alcoholic media formed during the fermentative process. Stillage is the main residue from ethanol production, containing a high organic loading in addition to acidic and corrosive characteristics. Considering the available technologies to treat stillage, we highlight anaerobic digestion, which allows the reduction of the impacts associated to pollutants loading of this effluent and the generation of energy from the methane gas produced in the process. Based on the high treatment efficiency usually associated to the anaerobic process, this work aimed to assess whether anaerobic systems applied to the treatment of stillage are energetically self-sufficient. First we evaluated the energy recovery capacity in an anaerobic reactor applied to the treatment of stillage resulting from corn-to-ethanol processing. The results indicated the great influence that a correct selection of electrical equipment and their respective operating periods have on the net energy balance of the anaerobic treatment. The high energy consumption of the heater would not allow the system to achieve a positive net energy balance – the maximum energy recovery would reach only 0.68% of the consumption. However, the replacement of the mixture equipment would result in energy gains ranging from 8.5 to 967.9% of the consumption. In this work we also assessed the efficiency of methane yields for a few studies and the correlation between some parameters of the anaerobic process. With respect to the methane yield, we noted that mesophilic systems tend to be more advantageous than the thermophilic ones (efficiency of 76.45 ± 22.51% vs. 69.40 ± 30.36%). Considering the study... (Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work analyzed the loss of sensible heat from one fluid to be considered homogeneous heat distribution on a thermal reservoir with cylindrical geometries composite insulating layers. We studied two thermal reservoirs with a volume of 20 liters, and the first has a layer thickness of 75 mm of expanding polyurethane foam wrapped in the polycarbonate container and the second container has only layer thickness of 5 mm of polycarbonate, as insulation of fluid of the external environment. The experimental results are compared with theoretical results obtained through a calculation script, displayed and detailed during the work development, from the theory of energy balance. The maximum error introduced between the theoretical and experimental results were 3.5% and 1.4% respectively for the Boilers with or without a polyurethane coating

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The anaerobic treatment of sewage is widely employed in Brazil and it is an appreciated way for the treatment of effluents, helping to reduce the environmental impact in rivers. The methane gas obtained from the process can be applied to improve the energetic efficiency of the system, reducing the amount of waste and the cost of the treatment process. This work presents the net energy balance of anaerobic reactors applied to the treatment of sewage. The analysis was performed considering full-scale and laboratory-scale treatment systems. In laboratory scale, the results from three kinds of systems were compared regarding the biological treatment of greywater. Two of them (UASB7 and UASB12) were anaerobic and the other one was a combined anaerobic-aerobic system (UASB7/SBR6). Greywater methanization (compared to theoretical maximum) was calculated considering 100% removal (g BOD/day), the literature percentage removal and the anionic surfactant presence in the effluentt. For each of these three cases, the efficiencies were, respectively, 16.9%, 43.6% and 51.3% in UASB7 reactor, 25.6%, 50.3% and 59.2% in UASB12 reactor and 30.6%, 61.2% and 71.9% in UASB7/SBR6 reactor. The energetic potential was found to be 4.66x10-4, 7.77x10-4 and 5.12x10-4 kWh/L for the UASB7, UASB12 and UASB7/SBR6 reactors, respectively. The pumping system, the aeration (in the anaerobic-aerobic system) and the temperature controlled heating system were considered to calculate the energetic consumption. However, the third one was not employed since tropical regions like Brazil do not need heating systems and also because of its high energetic consumption. The calculated net energy balance in the reactors was negative in the case of greywater, respectively -0.16, -0.28 and -0.18 kWh/L for the reactors UASB7, UASB12 and UASB7/SRB6. In full scale (ETE Jardim das Flores - Rio Claro, SP), the average energy... (Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Obesity along with overweight, has been considered one of the most serious public health problems in the world, especially because they are the main risk factors for many chronic diseases, such as coronary heart disease, type II diabetes mellitus, hypertension and some types of tumors, which are associated with high mortality rates. The use of functional foods and appropriate diets to call health promotion has grown as a mechanism for prevention, control and treatment of chronic diseases such as obesity. Several ethnopharmacological studies indicate plant species for the treatment of disorders associated with obesity with a major attraction of this regimen is perceived as safer and more effective health than the traditional treatment with appetite suppressants. This work aims to develop and standardize models of biological assays in stress and obesity, also aims to evaluate the effect of oil green beans of Coffea arabica in the regulation of body weight and energy balance in mice. To this end, trials were made in vivo studies of this product and their effects on energy metabolism in non-obese mice with obesity induced by hypercaloric diet. After induction of obesity by 8 weeks, animals were treated for 21 days with the extracts orally. After 21 days the animals were killed to evaluate the effects of these products on daily feed intake and on body weight. The group treated with the oil of Coffea arabica L. showed significant weight loss and feed intake high. According to the results, we conclude that the standardized extract of Coffea arabica L. decreased body weight without restriction or decrease the amount of food ingested

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This project aimed to analyze the feasibility of the methane yield associated to the anaerobic digestion of brewery residues, checking whether the energetic balance of the system is favorable. The methane yield efficiency was calculated for the parameters of two papers that treated solids with a particle-size <1mm. Theses solids are not degraded in conventional treatment systems. Calculations were based in the reactions of anaerobic degradation of the macromolecules that compose brewery residues, considering the theoretical production and the effective production of methane. The results were 50.44% and 52.86%. Regarding to the energy balance of the anaerobic treatment, we noted the high influence of the selection and operating regime of electrical equipment over the potential energy. The best situation, in which the energetic self-sufficiency was reached, was observed when using the mixer under an intermittent regime (1min/h), without employing the heating recirculator, for the maximum organic loading of 4.0 gVS/L.day (days 248-258). In this case, the system would generate an amount of energy equal to 0.0356 kWh/day, able to overcome the energy required by the equipment in about 6.5 times. Moreover, we also noted the interference of the application of different solid loadings in the reactors, once the application of the higher organic load generated 5 times more energy than the application of the smaller one