150 resultados para Water Distribution Networks Leak Detection I
Resumo:
In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.
Resumo:
One of the most important subjects of debate in the formation of the solar system is the origin of Earth's water. Comets have long been considered as the most likely source of the delivery of water to Earth. However, elemental and isotopic arguments suggest a very small contribution from these objects. Other sources have also been proposed, among which local adsorption of water vapor onto dust grains in the primordial nebula and delivery through planetesimals and planetary embryos have become more prominent. However, no sole source of water provides a satisfactory explanation for Earth's water as a whole. In view of that, using numerical simulations, we have developed a compound model incorporating both the principal endogenous and exogenous theories, and investigating their implications for terrestrial planet formation and water delivery. Comets are also considered in the final analysis, as it is likely that at least some of Earth's water has cometary origin. We analyze our results comparing two different water distribution models, and complement our study using the D/H ratio, finding possible relative contributions from each source and focusing on planets formed in the habitable zone. We find that the compound model plays an important role by showing greater advantage in the amount and time of water delivery in Earth-like planets. © 2013. The American Astronomical Society. All rights reserved.
Resumo:
This paper presents a mixed integer nonlinear programming multiobjective model for short-term planning of distribution networks that considers in an integrated manner the following planning activities: allocation of capacitor banks; voltage regulators; the cable replacement of branches and feeders. The objective functions considered in the proposed model are: to minimize operational and investment costs and minimize the voltage deviations in the the network buses, subject to a set of technical and operational constraints. A multiobjective genetic algorithm based on a Non-Dominated Sorting Genetic Algorithm (NSGA-II) is proposed to solve this model. The proposed mathematical model and solution methodology is validated testing a medium voltage distribution system with 135 buses. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biologia Animal - IBILCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Pós-graduação em Ciências Biológicas (Zoologia) - IBB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Over the past two years, Brazil has been facing a major water crisis in its history and the state of Sao Paulo is the one that has been going through worst difficulties. In this scenario, all water users should do everything possible so that the consumption of water resources is carried out in a sustainable manner. In this context, the companies responsible for the public water supply must increase the efficiency of water resource management. It is indispensable combating losses in the public supply system. When there is a non-visible leak in a pipe, the wastewater volume can be high, but in this case, the water returns to nature and continues to participate in the hydrological cycle. The economic loss corresponds to the value added to the product water, which includes the intrinsic costs of exploration, processing and distribution. This damage results in a reduced availability of financial resources of sanitation companies to invest in environmentally friendly solutions. This study aimed to diagnose the water distribution system in the city of Guaratinguetá (SP), held by the Companhia de Serviços de Água, Esgoto e Resíduos de Guaratinguetá (SAEG), to propose measures to combat water loss. Among the proposed measures, there is the monitoring of losses, planning for replacement of old pipes and company awareness as a whole in relation to combat water losses
Resumo:
The study aimed to evaluate the radial profile and the uniformity of water distribution of sprinkler manufactured by the company NaanDanJain, model 427 1/2 '' M and nozzle with 2.8 mm of internal diameter, operating at pressures of 150, 200, 300 and 400 kPa and five positions of the deflector (0, 20, 50, 80 and 100%). For the determination of the parameters evaluated, the grid method was used and with the help of computer application CATCH 3D, overlapping layers of water depths was calculated with ten spacing. The results show that the deflector adjustment influences the radius of wetness and the distribution profile while the uniformity of water application showed as an important mechanism, since it permits different behavior for the sprinkler, ensuring wide track of utilization of the equipment.
Resumo:
Em solos tropicais, a distribuição dos nutrientes no solo em função da fertirrigação realizada por meio de irrigação localizada (gotejamento e/ou microaspersão), na cultura de citros, é pouco conhecida. Este trabalho teve por objetivo avaliar os padrões de distribuição de potássio, cálcio, magnésio e fósforo em solo tropical, em função da fertirrigação, aplicada por dois sistemas de irrigação localizada (microaspersão e gotejamento), sendo que o sistema por gotejamento era composto por uma e duas linhas laterais por linha de plantas, e o de microaspersão por apenas uma linha, e com três dotações hídricas (100%, 75% e 50%) da evapotranspiração da cultura (ETc), em um pomar de laranjeira. As fontes de fertilizantes utilizadas na fertirrigação foram o nitrato de amônio (fonte de N), o cloreto de potássio (fonte de K+) e o ácido fosfórico (fonte de P). Observouse que, sob o emissor, nos tratamentos com gotejamento, houve depleção nos teores de Ca++ e Mg++ desde a superfície do solo até 60 cm de profundidade em relação aos teores anteriores às fertirrigações, enquanto os teores de P aumentaram, principalmente na camada de 0 cm a 20 cm. Na microaspersão, esses efeitos não foram observados, ocorrendo distribuição mais homogênea desses nutrientes tanto na direção transversal à linha de plantas quanto em profundidade. As lâminas de irrigação aplicadas por irrigação localizada não interferem na distribuição de K+ aplicado por fertirrigação e do Ca++ e Mg++ no solo em profundidade, porém menores lâminas de irrigação promovem maior concentração de P na camada mais superficial do solo, e lâminas maiores carregam o P para camadas mais profundas.
A new method for real time computation of power quality indices based on instantaneous space phasors
Resumo:
One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss, etc. but can create safety and technical problems as well. This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so-called Buchholz-Goodhue effective apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)