139 resultados para PHOTOMETRIC STANDARD STARS
Resumo:
Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Usually referral letters are the only means of communication between general practitioners and specialists in the health area. However, they are inadequate if important basic data are omitted. The aim of this study was to compare the content of standard and non-standard letters. A total of 1956 files from the Oral Medicine Service were consecutively evaluated (March 1996 to September 2000). Key items were considered for analysis and the results were stored in a database using the Epinfo 6.04 program. The X-2 test (a=0.05) was applied to the results. of the 1956 files examined, 34% (662) had a referral letter, 31% of them being standard letters and 69% non-standard letters. Most standard letters (87%) were from professionals of public health institutions. Most percent discrepancies between standard and non-standard letters were observed for patient address (14.90 vs 1.32%), patient age (54.81 vs 9.47%), chief complaint (32.21 vs 8.37%), fundamental lesion (29.33 vs 13.66%), and symptoms (27.81 vs 15.42%,,). Statistically significant differences were observed for patient age, professional referring the patient, chief complaint, and site of the lesion. The quality and quantity of the information differed significantly between the two types of letters. The standard letters were more complete and contained information commonly absent in the non-standard letters. We suggest the use of standard letters for improving the quality of communication among professionals.
Resumo:
Organotin compounds, largely used as biocides in antifouling paints, are among the most toxic materials introduced into the aquatic environment. Sensitive analytical methods are thus required to characterize their occurrence in environmental and biological matrices. The comparison between two different photometric detectors in terms of analytical performance was carried out for the analysis of organotin compounds. A flame photometric detector (FPD) and a pulsed flame photometric detector (PFPD) were optimized. Their respective sensitivity, linearity range and selectivity were evaluated. Limits of detection obtained for a tributyltin compound (TBT) were 5.0 and 0.9 pg (as Sn) for the FPD and PFPD, respectively, using a 390 nm filter. The PFPD showed higher selectivity, besides reduced gas consumption in the flame, and is very attractive for organotin compound speciation in complex environmental matrices.
Resumo:
Fluoroindate glasses of the following compositions: (40-x)InF3-20ZnF(2)-16BaF(2)-20SrF(2)-2GdF(3)-2NaF-xTmF(3) with x = 1,3 mol% were prepared in a dry box under an argon atmosphere. The absorption spectra at room temperature in the spectral range 350-2200 nm were obtained. The spectra obtained for each sample had similar absorption and only the amplitude of the different bands changed as the concentration of Tm3+. The experimental oscillator strengths were determined from the areas under the absorption bands. Using the standard and modified Judd-Ofelt theory, intensity parameters Ohm(lambda) (lambda = 2,4,6) and (lambda = 2,3,4,5,6), respectively for f-f transitions of Tm3+ ions as well as transition probabilities, branching ratios and radiative lifetimes for each band were determined. The results are compared with those of other glasses described in the literature. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
This article discusses the development of a test bench and a methodology for the study of composite resin abrasive wear. To evaluate the operation of the test bench and to compare the proposed methodology with other existing ones, a study was made of the five composites most commonly used by dentists.The one-way ANOVA method and the Tukey test were used to statistically analyze the results by multiple comparisons of the groups of resins tested. Using the proposed methodology, these resins were classified in an increasing order of abrasive wear strength, as follows: Charisma (the lowest abrasive wear strength), Tetric, TPH, Herculite and Z-100 (the highest abrasive wear strength) (P < 0.05). In comparison to other methodologies, the results of the proposed methodology presented the lowest coefficient of variation. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
The evaluation of the microscopic generalized interacting boson model (GIBM) Hamiltonian, deduced from the general microscopic nuclear Hamiltonian via the collective O-A-1 invariant microscopic Hamiltonian of the general restricted dynamics model (RDM) in the case of central multipole and multipole-Gauss type effective NN-potential is briefly discussed. The GIBM version, which includes all sixth-order terms in the expansion of the collective part of the NN-potential, has been obtained. This GIBM Hamiltonian contains additional terms compared with the standard (sd-boson) interacting boson model (IBM). The microscopic expressions for the standard IBM Hamiltonian parameters in terms of the employed effective NN-potential parameters have also been obtained.
Resumo:
The feasibility of using internal standardization (IS) to correct for interferences in hydride generation with in situ trapping in graphite furnace was evaluated. Arsenic was chosen as internal standard for Sb determination and Ir was used as permanent modifier. Fluctuations in the main parameters that affect the analytical results were minimized by IS and an effective contribution was verified in the studies of liquid phase interferences. Cobalt and Ni2+ were selected to illustrate the potential use of IS on the correction of interference by transition metals. The application of IS allows the Sb determination in samples containing up to 20-fold higher concentration of the Co2+ and Ni2+ when compared to the procedure without IS. The relative standard deviation of measurements varied from 0.3% to 0.7% and from 1.1% to 3.2% with and without IS, respectively. Recoveries within 92% and 107% of spiked aqueous solution containing Sb(III) and Sb(V) were found. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The need for standardization of the measured blow count number N-spt into a normalized reference energy value is now fully recognized. The present paper extends the existing theoretical approach using the wave propagation theory as framework and introduces an analysis for large displacements enabling the influence of rod length in the measured N-spt values to be quantified. The study is based on both calibration chamber and field tests. Energy measurements are monitored in two different positions: below the anvil and above the sampler. Both experimental and numerical results demonstrate that whereas the energy delivered into the rod stem is expressed as a ratio of the theoretical free-fall energy of the hammer, the effective sampler energy is a function of the hammer height of fall, sampler permanent penetration, and weight of both hammer and rods. Influence of rod length is twofold and produces opposite effects: wave energy losses increase with increasing rod length and in a long rod composition the gain in potential energy from rod weight is significant and may partially compensate measured energy losses. Based on this revised approach, an analytical solution is proposed to calculate the energy delivered to the sampler and efficiency coefficients are suggested to account for energy losses during the energy transference process.
Resumo:
This study investigated if overfed rats present morphological and histochemical muscle adaptation similar to normally fed, both submitted to two different weekly frequencies of training. Thirty male Wistar rats were fed either with standard chow (SCO) or with hypercaloric diet (HCO). They were subdivided into six subgroups: sedentary (SCO and HCO), trained twice/week (SC2 and HC2) and trained five times/week (SC5 and HC5). The trained groups swam 60 min/day, during 10 weeks. Twenty four hours after the last training, samples of Gastrocnemius were excised and stained with HE, NADH-TR and m-ATPase, and the capillary density was calculated. Total heart mass (HM) and the mass of atrium (AM), left (LV) and right (RV) ventricles were excised and weighted. The comparisons were made by ANOVA and by Covariance analysis, adjusting the variables by body weight. The results showed that the HCO achieved higher BM, however, absolute HM did not differ post training. Irrespective of the diet, rats that were trained twice a week presented significantly greater increase in the AM. In general, the SC5 and HC5 groups showed higher HM, LV, RV, proportion of oxidative fibres and capillary density, compared to the sedentary and twice week trained groups. A higher proportion of injuries (splitting) was noted in the HC2 and HC5 compared to SC2 and SC5. These results indicate that the frequency of training influenced the skeletal and heart adaptation and larger changes were observed in the 5x/week group, which ingested the standard diet. The 5x/week training groups also presented large amount of muscle fibres damage.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Studies on conjugated linoleic acid ingestion and its effect on cardiac tissue are necessary for the safe utilization of this compound as supplement for weight loss. Male Wistar 24-rats were divided into four groups (n = 6):(C)given standard chow, water and 0.5 ml saline, twice a week by gavage; (C-CLA)receiving standard chow, water and 0.5 ml of conjugated linoleic acid, twice a week, by gavage; (S)given standard chow, saline by gavage, and 30% sucrose in its drinking water; (S-CLA)receiving standard chow, 30% sucrose in its drinking water and conjugated linoleic acid. After 42 days of treatment S rats had obesity with increased abdominal-circumference, dyslipidemia, oxidative stress and myocardial lower citrate synthase(CS) and higher lactate dehydrogenase(LDH) activities than C. Conjugated linoleic acid had no effects on morphometric parameters in C-CLA, as compared to C, but normalized morphometric parameters comparing S-CLA with S. There was a negative correlation between abdominal adiposity and resting metabolic rate. Conjugated linoleic acid effect, enhancing fasting-VO2/surface area, postprandial-carbohydrate oxidation and serum lipid hydroperoxide resembled to that of the S group. Conjugated linoleic acid induced cardiac oxidative stress in both fed conditions, and triacylglycerol accumulation in S-CLA rats. Conjugated linoleic acid depressed myocardial LDH comparing C-CLA with C, and beta-hydroxyacyl-coenzyme-A dehydrogenase/CS ratio, comparing S-CLA with S. In conclusion, dietary conjugated linoleic acid supplementation for weight loss can have long-term effects on cardiac health. Conjugated linoleic acid, isomers c9, t11 and t10, c12 presented undesirable pro-oxidant effect and induced metabolic changes in cardiac tissue. Nevertheless, despite its effect on abdominal adiposity in sucrose-rich diet condition, conjugated linoleic acid may be disadvantageous because it can lead to oxidative stress and dyslipidemic profile. (c) 2007 Elsevier B.V All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Two wafers of the NIST (formerly NBS) glass standard SRM 612 recently irradiated have been compared to the pre-irradiated wafers RT3 and RT4 of glass SRM 962-7, stored for 9 years at 5°C, and SRM 962, stored for 20 years at room temperature. Track area densities on internal surfaces of the glass as well as track size measurements suggest that (1) the old SRM 962 and the more recent SRM 962a calibrations are consistent and (2) annealing of the fission tracks in the pre-irradiated wafers is negligible. This last experimental result enables a direct comparison of contemporary and previous fission track age calibrations. © 1995.
Resumo:
A rapid and simple method was developed for quantitation of polar compounds in fats and oils using monostearin as internal standard. Starting from 50 mg of oil sample, polar compounds were obtained by solid-phase extraction (silica cartridges) and subsequently separated by high-performance size-exclusion chromatography into triglyceride polymers, triglyceride dimers, oxidized triglyceride monomers, diglycerides, internal standard and fatty acids. Quantitation of total polar compounds was achieved through the internal standard method and then amounts of each group of compounds could be calculated. A pool of polar compounds was used to check linearity, precision and accuracy of the method, as well as the solid-phase extraction recovery. The procedure was applied to samples with different content of polar compounds and good quantitative results were obtained, especially for samples of low alteration level.