129 resultados para Mechanical Test Equipment.
Resumo:
This study evaluated the effects of mechanical and thermal cycling on the flexural strength (ISO 9693) of three brands of ceramics fused to commercially pure titanium (cpTi). Metallic frameworks of 25 x 3 x 0.5 mm dimensions (N = 84) were cast in cpTi, followed by 150-mu m aluminum oxide airborne particle abrasion at a designated area of the frameworks (8 x 3 mm). Bonder and opaque ceramic were applied on the frameworks, and then the corresponding ceramic (Triceram, Super Porcelain Ti-22, Vita Titankeramik) was fired onto them (thickness: 1 mm). Half of the specimens from each ceramic-metal combination were randomly tested without aging (only water storage at 37 degrees C for 24 hours), while the other half were mechanically loaded (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and thermocycled (3,000 cycles, between 5-55 degrees C, dwell time of 13 seconds). After the flexural strength test, failure types were noted. Mechanical and thermal cycling decreased the mean flexural strength values significantly (p<0.05) for all the three ceramic-cpTi combinations tested when compared to the control group. In all the three groups, failure type was exclusively adhesive at the opaque ceramic-cpTi interfacial zone with no presence of ceramic on the substrate surface except for a visible oxide layer.
Resumo:
A dispersão da amostra de solo é uma etapa fundamental da análise granulométrica, sendo realizada mediante o uso de dispersantes químicos e agitação mecânica. O objetivo deste trabalho foi avaliar a eficiência de mesa agitadora reciprocante de baixa rotação na dispersão mecânica de amostras de solos de diferentes classes texturais. Foram realizadas análises granulométricas em 61 amostras com quatro repetições, empregando o método da pipeta para determinação da fração argila e tamisagem para determinação das frações areia grossa, areia fina e areia total, sendo o silte determinado por diferença. Na avaliação de desempenho, os resultados obtidos com uso da mesa agitadora reciprocante (MAR) foram comparados com dados disponíveis para as mesmas amostras oriundos de relatórios do Ensaio de Proficiência IAC para Laboratórios de Análises de Solos - Prolab/IAC. Análises de acurácia foram realizadas com base nos valores dos intervalos de confiança definidos para cada fração granulométrica componente de cada amostra ensaiada. Indicadores gráficos também foram utilizados na comparação de dados, por meio de dispersão e ajuste linear. A estatística descritiva indicou preponderância de baixa variabilidade em mais de 90 % dos resultados obtidos para as amostras de texturas arenosa, média e argilosa e em 68 % dos obtidos para as amostras de textura muito argilosa, indicando boa repetibilidade dos resultados obtidos com a MAR. Média variabilidade foi mais frequentemente associada à fração silte, seguida da fração areia fina. Os resultados das análises de sensibilidade indicam acurácia de 100 % nas três frações granulométricas - areia total, silte e argila - para todas as amostras analisadas pertencentes às classes texturais muito argilosa, argilosa e média. Para as nove amostras de textura arenosa, a acurácia média foi de 85,2 %, e os maiores desvios ocorreram em relação à fração silte. Nas aproximações lineares, coeficientes de correlação igual (silte) ou superiores (areia total e argila) a 0,93, bem como diferenças menores do que 0,16 entre os coeficientes angulares das retas e o valor unitário, indicam alta correlação entre os resultados de referência (Prolab/IAC) e os obtidos nos ensaios com a MAR. Conclui-se pelo desempenho satisfatório da mesa agitadora reciprocante de baixa rotação para dispersão mecânica de amostras de solo de diferentes classes texturais para fins de análise granulométrica, permitindo recomendar o uso alternativo do equipamento quando se emprega agitação lenta. As vantagens do uso do equipamento nacional incluem o baixo custo, a possibilidade de análise simultânea de grande número de amostras e o uso de frascos comuns, de vidro ou de plástico, baratos e de fácil reposição.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The widespread falsification and/or adulteration of commercially available pharmaceutical preparations call for reliable methods of drug identification, preferably through selective and rapid sorting color tests that could be undertaken with minimum equipment remote from laboratory facilities. The present work deals with a convenient adaptation and refinement of a spot test devised by Feigl (1966) for urotropine, based on the hydrolytic cleavage of that substance in the presence of sulfuric acid, splitting out formaldehyde which is identified by its color reaction with chromotropic acid. A simple emergency kit was developed for the quick, efficient, inexpensive and easy performance of urotropine tests by semiskilled personnel even in the drugstore laboratory (or office) as well as in a mobile screening operation. It is shown that when the reagents are added according to the recommended sequence a self-heating system is generated, increasing substantially the reactions' rates and the test sensitivity as well. The identification limit found was 25 mug of urotropine, for both solid and liquid samples. The possible interference of 84 substances/materials was investigated. Interference was noted only for methylene blue, acriflavine, Ponceau Red, Bordeaux Red (these dyes are often included in urotropine dosage forms), pyramidone, dipyrone, quinine and tetracycline. A simple procedure for removing most of the interferences is described. Data for 8 commercial dosage forms and results obtained from their analysis are presented.
Resumo:
Background: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants.Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 x 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration.Results: the removal torque results were 30.5 (+/- 9.8) Ncm for group A, 50.17 (+/- 17.5) Ncm for group B, and 26 (+/- 7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P < 0.05) and groups B and C (P < 0.01).Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone.
Resumo:
This study evaluated the effect of mechanical cycling on the bond strength of fiber posts bonded to root dentin. The hypotheses examined were that bond strength is not changed after fatigue testing and bond strength does not present vast variations according to the type of fiber post. Sixty crownless, single-rooted human teeth were endodontically treated, with the space prepared at 12 mm. Thirty specimens received a quartz fiber post (Q-FRC (DT Light-Post), and the remaining 30 specimens received a glass fiber post (G-FRC) (FRC Postec Plus). All the posts were resin luted (All Bond+Duolink), and each specimen was embedded in a cylinder with epoxy resin. The specimens were divided into six groups: G1-Q-FRC+no cycling, G2- Q-FRC+20,000 cycles (load: 50N, angle of 45 degrees; frequency: 8Hz); G3- Q-FRC+2,000,000 cycles; G4- G-FRC+no cycling; G5- G-FRC+20,000 cycles; G6- GFRC+2,000,000 cycles. The specimens were cut perpendicular to their long axis, forming 2-mm thick disc-samples, which were submitted to the push-out test. ANOVA (alpha=.05) revealed that: (a) QFRC (7.1 +/- 2.2MPa) and G-FRC (6.9 +/- 2.1MPa) were statistically similar (p=0.665); (b) the no cycling groups (7.0 +/- 2.4MPa), 20,000 cycles groups (7.0 +/- 2.1MPa) and 2,000,000 cycles groups (7.0 +/- 2.0MPa) were statistically similar (p=0.996). It concluded that mechanical cycling did not affect the bond strength of two fiber posts bonded to dentin.
Resumo:
Ranzini (1988) proposed the Standard Penetration Test with torque measurement (SPT-T) and some geotechnical engineers in Brazil have been using it since 1991. This paper presents the state of the art on SPT-T testing, emphasizing what is already established as common knowledge in Brazilian engineering practice, besides a suggestion for test procedure, including equipment and practical aspects. In addition, the study of the shape of the torque versus rotation-degree angle curve obtained by an electric torquemeter used in several SPT-T tests carried out on six experimental research sites in the southeast region of Brazil is discussed here. Four different methods to predict pile capacity based on SPT-T test results are briefly presented and a comparison with load tests carried out on different types of piles, on those six experimental research sites, is presented.
Resumo:
Injection metering systems are an important option for the development of pesticide application equipment, with advantages relating to minimising the need for disposal of unused pesticide, improving the ease of cleaning and optimising the accuracy of chemical application. For all injection systems, characteristics such as the steady-state accuracy of delivered dose, dose stability and the time response for dose step changes are related to the ability of the system to operate with different chemical formulations. A system designed to inject liquids should be able to accommodate changes in viscosity and density. The aim of this study was to develop a methodology for testing chemical injection systems using liquids with different viscosities. The experimental arrangement simulating applications with injection metering systems used dye and salt solutions as tracers. Tests were conducted to analyse the influence of salt on the characteristics of the water and a viscous solution. Results showed that the salt interfered with the dye stability in the water solution. In tests with a viscous test liquid, the salt was introduced at different steps during the mixing process, providing four different liquids to be analysed in terms of viscosity, density and pH. Some differences in liquid characteristics were found which could influence the performance of the injection systems.
Resumo:
Objectives. The aim of this study was to evaluate the effect of mechanical cycling on the biaxial flexural strength of two densely sintered ceramic materials.Methods. Disc shaped zirconia (In-Ceram Zirconia) and high alumina (Procera AllCeram) ceramic specimens (diameter: 15 min and thickness: 1.2 mm) were fabricated according to the manufacturers' instructions. The specimens from each ceramic material (N = 40, n = 10/per group) were tested for flexural strength either with or without being subjected to mechanical cycling (20,000 cycles under 50 N load, immersion in distilled water at 37 degrees C) in a universal testing machine (1 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (alpha = 0.05).Results. High alumina ceramic specimens revealed significantly higher flexural strength values without and with mechanical cycling (647 +/- 48 and 630 +/- 143 MPa, respectively) than those of zirconia ceramic (497 +/- 35 and 458 +/- 53 MPa, respectively) (p < 0.05). Mechanical cycling for 20,000 times under 50 N decreased the flexural strength values for both high alumina andSignificance. High alumina ceramic revealed significantly higher mean flexural strength values than that of zirconia ceramic tested in this study either with or without mechanical cycling conditions. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The compaction rate, the relation between the density of the wood panel and the density of the wood used for producing the particles, is an indicator of the product's densification. Among the various types of wood panels, particleboards are widely employed in the lumber industry, mainly for the furniture production. This paper presents a study of the relation between the compaction rate and the properties of tensile strength perpendicular to surface, Modulus of Rupture (MOR) and Modulus of Elasticity (MOE) obtained from a static bending test, thickness swelling and water absorption (2 and 24 hours). These properties were calculated according to the Brazilian ABNT, NBR 14810 standard. Particleboards were produced using the species Pinus elliotti and adhesive ureaformaldehyde. The relation was established by a multiple linear regression, and the most appropriate statistical models were determined. The estimated models indicate statistically significant effects of water absorption in 2 hours and MOR in the particleboards' compaction rate.
Resumo:
This work shows the preparation and characterization of composites obtained by mixing natural rubber (NR) and carbon black (CB) in different percentages aiming suitable mechanical properties, processability and electrical conductivity for future applications as transducers in pressure sensors. The composites NR/CB are characterized through dc conductivity, thermal analysis using differential scanning calorimetry (DSC), dynamic mechanical thermal analysis (DMA), thermogravimetry (TGA) and stress-strain test. The electrical conductivity changed from 10-9 to 10 Sm-1 depending on the percentage of CB in the composite. Besides, it was found a linear (and reversible) dependence of the conductivity on the applied pressure in the range from 0 to 1.6 MPa for the sample 80/20 (NR/CB wt%).
Resumo:
In the work described in the present paper, an analytical solution of the general heat conduction equation was employed to assay the temperature profile inside a solid slab which is initially at room temperature and is suddenly plunged into a fluid maintained at a high temperature. The results were then extrapolated to a simulation of a hot modulus of rupture test of typical MgO-graphite refractory samples containing different amounts of graphite in order to evaluate how fast the temperature equilibrates inside the test specimens. Calculations indicated that, depending on the graphite content, the time to full temperature homogenization was in the range of 80 to 200 s. These findings are relevant to the high temperature testing of such refractories in oxidizing conditions in view of the graphite oxidation risks in the proper evaluation of the hot mechanical properties.
Resumo:
It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.
Resumo:
Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. This paper presents a study of the rod length influence in the torque measurement. A theoretical study of material resistance considering torsion and bending in a thin wall tubular steel shaft was performed. It makes possible to conclude that the shearing tension caused by the proper weight represents less than 1% of the shearing tension caused by the turning moment. In addition, an experimental study was done with electric torquemeters fixed in a horizontal rod system. The tests were being carried out to analyze rods of one meter to twenty meters in length and the measurements were collected at the ends of each rod length verifying the efficiency data. As a result, it is possible to verify that the torque difference through rod length is lower than minimum scales of mechanical torquemeters that are used on practical engineering. Also a fact to be considered is a big torque loss for values under 20 N.m of applied torque. This way, the SPT-T is not adequate to low consistency soil. Copyright ASCE 2007.