84 resultados para MEJORAMIENTO NORMA ISO 9001:2008
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
The process of steel production emits a large quantity of greenhouse gases, specifically carbon dioxide (CO2), and the reduction of such emissions is one of the main challenges for the industry in the 21st. Century. To quantify these emissions, the Worldsteel Association (association of the 170 large steel manufacturers of the world) published a methodology (CO2 Emission Data Collection) for calculation and comparison of CO2 emissions among its members. After that, in 2010, this methodology became an ISO (International Organization for Standardization) norm. Today, the calculation of the CO2 emissions in steel making companies follow the ISO 14404-1 for units with blast furnaces and the ISO 14404-2 for units with electric furnaces. In the last years, new technologies were and continue to be developed for the steel making sector aiming at energetic improvements and greenhouse gas reductions (mainly CO2) by the several processes involved in the production of steel. This work had the objective of producing a tool to calculate the CO2 emissions for the steel making sector. An Excel spreadsheet was developed to calculate the emission intensities of CO2 of a steel plant, the Usina Presidente Vargas, of the Companhia Siderúrgica Nacional (CSN). The spreadsheet furnishes results of CO2 emissions and energetic fluxes, and simulates the benefits that some of the new technologies can give to the company. The spreadsheet calculates the emissions in two ways: a) based on the carbon fluxes that enter the unit, and b) based on the emissions of each specific process within the unit (coking, sinterization, blast furnace, among others)
Resumo:
The aim of this study was to evaluate the influence of specimen size, in comparison with the ISO Standard, on the three point flexural strength of resin composite restorative materials Filtek Supreme and Filtek Z-250. Forty specimens were fabricated for each material with the following length, width and thickness measurements (n = 10): 1) 20 × 2 × 2 mm (ISO 4049); 2) 10 × 2 × 1 mm; 3) 10 × 1 × 1 mm; 4) 8 × 0.8 × 0.8 mm. The composites were inserted in a single increment into two-piece metal device and light-polymerized. The specimens were dry stored at 37 ± 1 °C and protected from light for 7 days. After this period, flexural strength was measured by three-point flexure test using MTS 810 equipment, with a load cell of 10 kN at a speed of 0.5 mm/min. For the evaluated sizes, the results showed significant variability (p = 0.00) with values when compared with the ISO Standard (116.700 MPa), being statistically higher for the test specimens measuring 10 × 1 × 1 mm (142.530 MPa), similar for those of 10 × 2 × 1 mm (115.815 MPa) and lower for those of 8 × 0.8 × 0.8 mm (86.650 MPa). There was statistical equality (p = 0.08) for the studied composites (Filtek Supreme, 125.270 MPa; Filtek Z-250, 108.130 MPa). Specimens measuring 10 × 2 × 1 mm provided flexural strength values equivalent to those obtained in the sizes recommended by the ISO 4049 standard, with lower consumption of material, energy and time.
Resumo:
The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The dentist has been suggested as a professional vulnerable to labor risks mainly related to working posture. This study examined the application of ergonomics principles during the dental attendances made by university student of the last period of the Araçatuba Dental University. Twenty-four attendants were photographed and the images were digitally analyzed for the verification of 10 requirements that determine a healthy labor posture, defined by the project ISO Standard / TC 106/SC 6 N 411. It was observed that 50% of items from the check list obtained higher percentages of negative replies. The students had greater difficulties as to the correct position of the angle between the upper and lower leg when sitting, the ideal adjustment of the light focus reflector in the field of work and the patient positioning. It was concluded that the dental attendances were held without compliance with the ergonomic requirements. The greatest difficulties regarding the work posture were the sitting posture, the light beam and the patient positioning. Students need better guidance about ergonomic principles and requirements, which should occur at any time of life, but earliest they are installed, greater the benefits, assimilation and incorporation of adequate working postures will be. We need a reform that addresses all sectors of the dental system, so that learning and application of ergonomics in dentistry become effective, efficient and effective.
Resumo:
Este artigo tem o propósito de examinar os desafios e oportunidades relacionados à implementação de sistemas de gestão ambiental baseados na Norma ISO 14001:2004 nas Instituições de Ensino Superior e como elas podem se adequar aos requisitos para possuir um sistema de gestão ambiental (SGA). O estudo envolve análises sobre as implicações da adoção de sistemas de gestão ambiental por universidades e sobre os aspectos relevantes na adoção de SGAs com base na Norma ISO 14001, como barreiras, benefícios, motivações, práticas e fatores críticos de sucesso. Luzes são lançadas, assim, a um tema de crescente importância (sistemas de gestão ambiental), com foco em objeto analítico ainda pouco analisado do ponto de vista ambiental (Instituições de Ensino Superior).
Resumo:
The product portfólio management is considered relevant activity to the proper performance of the product development process. This paper aims to present the main methods of management that technology-based small businesses adopt for decision-making in product portfolio. This survey, which collected data on 31 companies was conducted. It was observed that although firms adopt market research and mapping methods and financial methods and for this decision-making, most of them based on the informal deliberations of senior management. Unable to understand the business relationships between the presence of ISO 9001 certification with greater formalization for decision making in product portfolio.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência da Informação - FFC
Resumo:
Machining processes are one of the most important manufacturing processes in the modern world. In these processes, there are many elements which will influence in the final result of the machined part. Among them, the tools are the principal factor of the rising cost, because its global influence on the process. In aeronautical industries, this can be more evidenced due the need to machining several alloys, between them, aluminum alloys. These alloys have to demonstrate a specific surface finishing to be used in aircraft's fuselage. This kind of industry is one of the segments which is still rising in Brazil, and they are looking viable alternatives in the manufacturing processes of materials, due the need to produce more and more parts and equipment, with costs increasingly reduced. The purpose of this project is the development of a ceramic with differentiated properties. The ceramics were developed using a pre-sintering at 1200 °C, with posterior sintering at 1600°C, and subjected to dry turning process on aluminum alloy 6005. The characterizations showed that ceramics presented with toughness on the center of 1700 MPa and on the surface of 1950 MPa, density 98,5 ±0,14. g/cm³. Ceramics were grinded and faceted, according to ISO standard 1832, and subjected to turning tests in a ROMI lathe brand, model GL240M, using cutting speeds of 500, 800 and 1000 m/min with different feed rates. The machining results showed low occurrence of flank wear to all cutting speeds, and better surface finishing average values of Ra = 0,4935 μm and Rt = 8,112 μm. In general, it could be seen that the tool presents important potential to machining 6005 alloy, and that the use of correct parameters can decrease and/or eliminate subsequent processes, providing important reductions in costs related to the machining processes