202 resultados para BIS(4-PYRIDYL)DISULFIDE-MODIFIED GOLD ELECTRODE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Silver nanoparticles (Ag) were deposited on multi-walled carbon nanotube by eletroless. The hybrid Ag/MWCNT was used in the modification of glassy carbon electrode (GC) surface. The electrochemical characterization confirmed the presence of Ag in the nanocomposite has been showed that the synthesis was successful. The GC electrode modified with Ag/MWCNT film was evaluated for electro-oxidation of benzene. The electrochemical behavior presented an improvement on the catalytic surface in relation to non-modified GC electrode. The anodic peak current increased the magnitude in three times when compared with the CG electrode modified only with MWCNT
Resumo:
The reaction of [Pd{dmba}(l-N3)]2 (dmba = N,N-dimethylbenzylamine) with 1-(2-fluorophenyl)-3-(4- nitrophenyl)triazenido (L1 ) or 1,3-bis(4-nitrophenyl)triazenido (L2 ) anions, in methanol, and subsequent treatment with pyridine (py) allows the preparation of the corresponding cyclopalladated compounds [Pd(dmba)(L1 )(py)] (1) and [Pd(dmba)(L2 )(py)]py (2). The acentric mononuclear entities of (1) and (2) are connected by weak intermolecular non-classical CAHC hydrogen bonds, which results in 2-D arrangements by translation, along the [1 0 0] and [0 01] crystallographic directions, respectively.
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Takayasu's arteritis is a chronic inflammatory disease, and neurological symptoms occur in 50% of cases, most commonly including headache, dizziness, visual disturbances, convulsive crisis, transient ischemic attack, stroke and posterior reversible encephalopathy syndrome. The aim of this study was to report the case of a young Brazilian female with a focal neurological deficit. She presented with asymmetry of brachial and radial pulses, aphasia, dysarthria and right hemiplegia. Stroke was investigated extensively in this young patient. Only nonspecific inflammatory markers such as velocity of hemosedimentation and C-reactive protein were elevated. During hospitalization, clinical treatment was performed with pulse therapy showing improvement in neurological recuperation on subsequent days. In the chronic phase, the patient was submitted to medicated angioplasty of the brachiocephalic trunk with paclitaxel, with significant improvement of the stenosis. At the 6-month follow-up, the neurological exam presented mild dysarthria, faciobrachial predominant disproportionate hemiparesis, an NIHSS score of 4 and a modified Rankin Scale score of 3 (moderate incapacity). In conclusion, Takayasu's arteritis must be recognized as a potential cause of ischemic stroke in young females.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2,5-dimercapto-1,3,4-thiadiazole (DTTPSG-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to +0.8 V (vs. Ag/AgCl), (0.02 mol L-1 KNO3; nu=20 mV s(-1)) show two peaks one at about 0.0 V and other at 0.31 V. However, the cathodic wave peak, around 0.0 V, is irregular and changes its form in each cycle. This peak at about 0.0 V is the reduction current for mercury(II) accumulated in the DTTPSG-CPE. The anodic wave peak at 0.31 V is well-defined and does not change during the cycles. The resultant material was characterized by cyclic and differential pulse anodic stripping voltammetry performed with the electrode in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n=6) of 0.05 and 0.20 mg (L)-(1) Hg(II) was 2.8 and 2.2% (relative standard deviation), respectively. The method was satisfactory and used to determine the concentration of mercury(II) in natural waters contaminated by this metal.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The synthesis, characterization and catalytic activity of the cationic iron porphyrins Fe[M(4-N-MePy)TDCPP]Cl-2 and Fe[M(4-N-MePy)TFPP]Cl-2 in the epoxidation of (Z)-cyclooctene by PhIO in homogeneous solution and supported on silica gel (SG), imidazole propyl gel (IPG) or SG modified with 2-(4-sulfonatophenyl)ethyl groups (SiSO3) have been accomplished. When supported on IPG, both cationic FeP bind to the support via Fe-imidazole coordination. Fe[M(4-N-MePy)TDCPP]IPG contains a mixture of low-spin bis-coordinated (FeP)-P-III and high-spin mono-coordinated (FeP)-P-III species, whereas Fe[M(4-N-MePy)TFPP]IPG only contains high-spin mono-coordinated (FeP)-P-III. These FePIPG catalysts also contain (FeP)-P-II species, whose presence was confirmed by EPR spectroscopy using NO as a paramagnetic probe. Both cationic FePs coordinate to SG through Fe-O ligation and they are present as high-spin (FeP)-P-III species. The cationic FePs supported on SiSO3- are also high-spin (FeP)-P-III species and they bind to the support via electrostatic interaction between the 4-N-methylpyridyl groups and the SO3- groups present on the matrix. In homogeneous solution, both Fe[M(4-N-MePy)TDCPP]Cl-2 and Fe[M(4-N-MePy)TFPP]Cl-2 have similar catalytic activity to Fe(TDCPP)Cl and Fe(TFPP)Cl, leading to cis-epoxycyclooctane yields of 92%. When supported on inorganic matrices,both FePs lead to epoxide yields comparable to their homogeneous analogues and their anchoring enables catalyst recovery and re-use. Recycling of Fe[M(4-N-MePy)TDCPP]SiSO3- shows that this FeP maintains its activity in a second reaction. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
The construction of a flow-through cell incorporating an array of gold microelectrodes is described and its application to flow injection analysis with amperometric detection is presented, Simple modification of almost any conventional integrated circuit chip, used as an inexpensive source of pre-assembled gold micro-wires, leads to the rapid and successful preparation of arrays of 8-48 elements, the polymeric encapsulation material from the top face of the chip is removed by abrasion until the gold micro-mires (used to interconnect the silicon circuit to the external contact pins of the chip) are disrupted and their transversal (elliptical) sections become exposed. Once polished, the flat and smooth top surface of the gold microelectrode-array chip (MEAC) is provided with a spacer and fitted under pressure against an acrylic block with the reference and auxiliary electrodes, to form the electrochemical (thin-layer) flow cell, while the contact pins are plugged into a standard IC socket, This design ensures autonomous electric contact with each electrode and allows fast dismantling for polishing or substitution, the performance of flow cells with MEACs was investigated utilizing the technique of reverse pulse amperometry without oxygen removal, A method was established for the determination of the copper concentration in sugar cane spirit, regulated by law for beverages, Samples from industrial producers and small-scale (alembic) brewers were compared, With a 24 MEAC, a detection limit of 30 mu g I-l of copper (4.7 x 10(-7) mol l(-1) of Cu-II for 100 mu l injections) was calculated, Routine operation was established at a frequency of 60-90 determinations per hour, Intercomparison with atomic absorption spectrometric determinations resulted in excellent agreement.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work, a sensor was built up with smart material based on polymer brush and gold nanoparticles. The modified electrode functionalized with polyacrylic acid (PAA) tethered to indium tin oxide (ITO) and covered with gold nanoparticle (ITO/PAA/Au) demonstrated switchable interfacial properties discriminating different pHs. The switchable electrochemical and plasmonic process was characterized by cyclic voltammetry (CV), electrochemistry impedance spectroscopy (EIS), and localized surface plasmon resonance (LSPR).
Resumo:
The L-dopa is the immediate precursor of the neurotransmitter dopamine. Unlike dopamine, L-dopa easily enters the central nervous system and is used in the treatment of Parkinson's disease. A sensitive and selective method is presented for the voltammetric determination of L-dopa in pharmaceutical formulations using a carbon paste electrode modified with trinuclear ruthenium ammine complex [(NH3)(5)Ru-III-O-Ru-IV(NH3)(4)-O-Ru-III(NH3)(5)](6+) (Ru-red) incorporated in NaY zeolite. The parameters which influence on the electrode response (paste composition, potential scan rate, pH and interference) were also investigated. The optimum conditions were found to an electrode composition (m/m) of 25% zeolite containing 6.7% Ru, 50% graphite and 25% mineral oil in acetate buffer at pH 4.8. Voltammetric peak currents showed a linear response for L-dopa concentration in the range between 1.2 x 10(-4) and 1.0 x 10(-2) Mol l(-1) (r = 0.9988) with a detection limit of 8.5 x 10(-5) mol l(-1). The variation coefficient for a 1.0 x 10(-3) mol l(-1) L-dopa (n = 10) was 5.5%. The results obtained for L-dopa in pharmaceutical formulations (tablet) was in agreement with compared official method. In conclusion, this study has illustrated that the proposed electrode modified with Ru-red incorporated zeolite is suitable valuable for selective measurements of L-dopa. (C) 2004 Elsevier B.V. All rights reserved.