Efeitos da rugosidade superficial nas propriedades de passivação de monocamadas orgânicas automontadas


Autoria(s): Benites, Tiago A.; Ribeiro, Willian C.; Góes, Márcio S.; Ferreira, Antonio A. P.; Bueno, Paulo Roberto
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

02/02/2015

02/02/2015

2014

Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Precise surface area is needed for accurate characterization of self-assembled monolayers (SAMs) on metallic surfaces. The aim of this manuscript was to emphasize that miscalculation of surface area is the major source of errors in SAM electrochemical characterization. Limitations are discussed and recommendations given for beginners in analyses of SAM functionalized electrodes. The electrochemical measurements and examples were based on bare gold electrode immobilized with dodecanethiol. The degree of compression of the monolayer properties of formation and reproducibility of the electrochemical response depends on roughness factor, with values closer to the unit being better.

Formato

1533-1537

Identificador

http://dx.doi.org/10.5935/0100-4042.20140241

Química Nova. Sociedade Brasileira de Química, v. 37, n. 9, p. 1533-1537, 2014.

0100-4042

http://hdl.handle.net/11449/114539

10.5935/0100-4042.20140241

S0100-40422014000900018

S0100-40422014000900018.pdf

Idioma(s)

por

Publicador

Sociedade Brasileira de Química

Relação

Química Nova

Direitos

openAccess

Palavras-Chave #self-assembled monolayers (SAMs) #roughness #cyclic voltammetry
Tipo

info:eu-repo/semantics/article