171 resultados para Amélia Beviláqua


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To study the influence of color opacity and light-curing systems (halogen light vs blue LED) on the microhardness of a composite resin. Methods: Esthet-X composite resin (Dentsply), shades A2 and A2-O, was inserted in a stainless steel matrix (5 mm diameter and 2 mm deep) and was light cured for 40 seconds with a halogen light source (XL 3000; 3M/ESPE) or a blue LED (Optilight LD II; Gnatus). Eight groups of 15 specimens each were formed, and were further divided according to the light-curing systems, the exposed area (base and surface), and the opacity of the composite resin, producing 120 specimens. The specimens were next stored in distilled water for 24 hours, embedded in a chemically activated acrylic resin, then subjected to finishing and polishing with sandpaper and felt discs. Microhardness was measured with a Vickers Digital Microhardness meter, with a 50 g load for 30 seconds. The obtained microhardness means were analyzed by ANOVA and Tukey's multiple-comparison test at 5% significance level. Results: The surface microhardness was always greater than the base microhardness, regardless of the light-curing source. The halogen light lamp produced significantly higher composite resin microhardness means than the blue LED (57.61 vs. 42.53 HV) (p<0.05). Statistically significant differences (p<0.05) were obtained between the microhardness means for the different composite opacities; lowest microhardness in depth was produced by the A2-O shade. Conclusion: Composite resin opacity as well as the light-curing system influenced the microhardness of the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soft linings are materials used to reduce the tension and forces of mastication, forming all or part of the fitting surface of a denture. This study evaluated the effect of thermocycling on water absorption, solubility, Shore A hardness and color stability of permanent soft liner materials. MATERIAL AND METHODS: Two chemically activated soft liner materials (Sofreliner S; GC Reline Ultrasoft) were tested. Twenty cylindrical specimens (30.0 x 1.0 mm) were prepared for measuring water absorption and solubility and another twenty (30.0 x 3 mm) for analyzing Shore A hardness and color stability. Color was measured by a spectrophotometer before and after 2000 thermocycles. A one-way ANOVA test and Tukey test at a 5% confidence level (p<0.05) were performed. RESULTS: The results did not show statistical differences for water absorption, solubility or color stability. The post-thermocycling Shore A hardness values were significantly higher than those before the treatment. CONCLUSION: Thermocycling of soft liner materials increased Shore A hardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the description of several cases of feline leishmaniasis around the world, little information is available about the importance of the cat as a reservoir of the disease. The aim of the present study was to determine the occurrence of leishmaniasis in cats from an endemic area for visceral leishmaniasis in Brazil. Two hundred cats were included in this study. Infection was evaluated through the presence of amastigotes in stained smears from fine-needle aspirates of lymph nodes, bone marrow, spleen and liver, and by antibody reactivity against Leishmania chagasi using indirect ELISA. Our results showed a prevalence of infection in 14.5% (31/200) of the feline population studied, with 4% (8/200) of positivity by parasitological diagnosis and 11.5% (23/200) by serology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated the effects of disinfection and aging on the hardness of silicones containing opacifiers and intended for use in facial prosthetics. A total of 90 samples were produced using a cylindrical metal mold 3 mm in height and 30 mm in diameter. The samples were fabricated from Silastic MDX 4-4210 silicone in three groups: GI contained no opacifier, GII contained barium sulfate (Ba), and GIII contained titanium dioxide (Ti). The samples were disinfected using effervescent tablets (Ef), neutral soap (Ns), or 4% chlorhexidine (Cl) 3 times a week for 60 days. After this period the samples underwent 1,008 hours of accelerated aging. The hardness was measured using a durometer immediately following the disinfection period and after 252, 504, and 1,008 hours of aging. The data were statistically analyzed using 3-way ANOVA and the Tukey test (p < .05). The GIII group exhibited the greatest variation in hardness regardless of elapsed time. All groups displayed greater hardness after 1,008 hours of accelerated aging independent of disinfectant type. All of the hardness values were within the clinically acceptable range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite recent trends to decrease allogeneic red blood cell (RBC) transfusion thresholds, such transfusions remain an important supportive and life-saving intervention for neonatal intensive care patients. In neonates, apart from concerns about transfusionassociated infections, many controversial questions regarding transfusion practices remain unanswered. Moreover, neonates present specific clinical and immunologic characteristics that require selected blood component products. This article addresses many of these issues from a medical perspective, with emphasis on the best blood banking techniques to provide RBC products for neonatal transfusions. Copyright © 2011 by the American Academy of Pediatrics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The practice of teaching is permeated by adverse working conditions, low wages, inadequacy of material and teaching resources, overcrowded classrooms, tension in relationships with the students, excessive work load, lack of safety in the school environment, insignificant participation in institutional planning and in institutional politics. The objective of the present study was to compare burnout among three groups of teachers who work in elementary grades: a) 20 teachers who teach in regular school classrooms without the inclusion of students with special educational needs - RSI Group; b) 20 teachers who teach in the regular classroom with special needs students - RCI Group; c) 20 teachers who teach in resource classrooms (SR Group). The instruments used for data collection were the Maslach Burnout Inventory -MBI. The data was analyzed by SPSS version 13.0 and Kruskal-Wallis test for comparison of the three groups. The results were organized in the form of figures and tables. In general, the results demonstrated that the groups presented relative similarity. The teachers from the SR Group obtained the best results in the evaluation of the three burnout scales when compared to the RSI Group and RCI Group, that is, there was a prevalence of answers in the lower levels of emotional exhaustion, high level of low personal accomplishment and low level for depersonalization. It is hoped that these results contribute to a better understanding of burnout in teachers from regular classrooms with or without students with educational special needs and/or to indicate new directions for investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Feline immunodeficiency virus and feline leukemia represent important infectious diseases caused by retroviruses. This study aimed to investigate the prevalence of infection by feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) in cats from the municipality of Araçatuba, São Paulo. Blood samples from 302 cats were collected and tested for the presence of antibodies against feline immunodeficiency virus and antigen of feline leukemia virus by ELISA ® Snap- Combo FIV-FeLV (IDEXX Laboratories). The frequency of FIV positivity was 5.63% (17/302) and of FeLV was 0.33% (1/302). Of the 17 cats infected with FIV, nine (52.94%) were symptomatic. There was a prevalence of FIV infection in males (p 0.0316) and cats aged between one and three years (p 0.0324).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Materials and Methods: Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n=7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60days. All specimens were thermal cycled between 5 and 55°C with 30-s dwell times for 1000 cycles before and after disinfection. The specimens' colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T 1), after disinfection (D) and after second thermal cycling (T 2). Colour differences (ΔE) were calculated between T 1 and B (T 1B), D and B (DB), and T 2 and B (T 2B) time-points. Results: The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time-points, except for the Lucitone acrylic resin. Conclusions: The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Making an artificial iris with an aesthetically acceptable color is an important aspect of ocular rehabilitation. This work evaluated the influence of different disinfecting solutions on changes to the color of artificial irises used in ocular prostheses. Fifty samples simulating ocular prostheses were produced with cobalt blue artificial irises and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite, and 4% chlorhexidine. The samples were disinfected for 120 days and subjected to a color readings by spectrophotometry, using the CIE L*a*b* system, before the disinfection period (B), after 60 days of disinfectant exposure (T 1), and after 120 days of disinfectant exposure (T 2). Color differences (ΔE) were calculated for the intervals between T 1 and B (T 1B), and between T 2 and B (T 2B). The data were evaluated by analysis of variance and the Tukey Honestly Significantly Different (α = 0.05). All disinfectant groups exhibited color changes. The mean color change observed for all groups overall during T 2B (ΔE = 3.51) was significantly greater than that observed during T 1B (ΔE = 2.10). All groups exhibited greater color change for the b* values when compared to the a* and L* values. There were no significant differences between the disinfectant groups. It can be concluded that the time period of disinfection and storage significantly affected the stability of artificial iris color, independent of the disinfectant used. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although canine visceral leishmaniasis (CVL) has been extensively studied, muscular damage due to Leishmania (Leishmania) infantum chagasi infection remains to be fully established. The aim of this study was to describe the electromyographic and histological changes, as well as search for the presence of amastigote forms of Leishmania spp, CD3+ T-lymphocytes, macrophages and IgG in skeletal muscles of dogs with visceral leishmaniasis (VL). Four muscles (triceps brachial, extensor carpi radialis, biceps femoris and gastrocnemius) from a total of 17 naturally infected and six healthy dogs were used in this study. Electromyographic alterations such as fibrillation potentials, positive sharp waves and complex repetitive discharges were observed in, at least, three muscles from all infected dogs. Myocyte necrosis and degeneration were the most frequent muscular injury seen, followed by inflammatory reaction, fibrosis and variation in muscle fibers size. Immunohistochemistry in muscle samples revealed amastigote forms in 4/17 (23. 53%), IgG in 12/17 (70. 58%), CD3+ T-lymphocytes in 16/17 (94. 12%) and macrophages in 17/17 (100%) dogs. Statistically positive correlation was observed between: inflammatory infiltrate (p=0. 0305) and CD3+ immunoreaction (p=0. 0307) in relation to the number of amastigote forms; inflammatory infiltrate (p=0. 0101) and macrophage immunoreaction (p=0. 0127) in relation to the amount of CD3+; and inflammatory infiltrate (p=0. 0044) and degeneration/necrosis (p<0. 0001) in relation to the presence of macrophages. Our results suggest that different mechanisms contribute to the development of myocytotoxicity, including celular and humoral immune responses and direct muscular injury by the parasite. Nevertheless, the catabolic nature of the disease can probably interact with other factors, but cannot be incriminated as the only responsible for myositis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the effect of low-level laser therapy (LLLT) on the masticatory performance (MP), pressure pain threshold (PPT), and pain intensity in patients with myofascial pain. Twenty-one subjects, with myofascial pain according to Research Diagnostic Criteria/temporomandibular dysfunction, were divided into laser group (n = 12) and placebo group (n = 9) to receive laser therapy (active or placebo) two times per week for 4 weeks. The measured variables were: (1) MP by analysis of the geometric mean diameter (GMD) of the chewed particles using Optocal test material, (2) PPT by a pressure algometer, and (3) pain intensity by the visual analog scale (VAS). Measurements of MP and PPT were obtained at three time points: baseline, at the end of treatment with low-level laser and 30 days after (follow-up). VAS was measured at the same times as above and weekly throughout the laser therapy. The Friedman test was used at a significance level of 5 % for data analysis. The study was approved by the Ethics Committee of the Federal University of Sergipe (CAAE: 0025.0.107.000-10). A reduction in the GMD of crushed particles (p < 0.01) and an increase in PPT (p < 0.05) were seen only in the laser group when comparing the baseline and end-of-treatment values. Both groups showed a decrease in pain intensity at the end of treatment. LLLT promoted an improvement in MP and PPT of the masticatory muscles. © 2012 Springer-Verlag London.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the electromyographic and histopathological changes in skeletal muscles of dogs naturally infected by L. infantum. Twenty five mixed breed adult dogs with parasitological, molecular and serological diagnosis were selected. The evaluated muscles were: triceps brachial, extensor carpi radialis, biceps femoris and gastrocnemius. One dog had locomotor clinical signs with hind limbs paresis associated with severe muscle atrophy. Twenty-three (92%) had some type of muscular change, and in 22 (88%) such changes were directly identified by electromyography. Even without any clinical signs of the disease, 10 (40%) dogs had electromyographic and histopathological changes. Leishmania antigens were detected in muscles of four (16%) dogs. The electromyographic evaluation indicated the occurrence of chronic polymyositis in 13 (52%) dogs, the presence of both acute and chronic muscle inflammation four (16%), acute myopathy in two (8%) and absence of electromyographic abnormalities in three (12%) dogs. The most frequently observed histopathological changes were degeneration and necrosis of myofibers and inflammatory infiltration observed in 12 (48%) dogs. Other changes were decreased diameter of muscle fibers in 15 (60%) and peri or endomysial fibrosis in 14 (56%) animals. The changes observed in the present study showed that even in the absence of clinical signs, most dogs infected by Leishmania infantum have chronic polymyositis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of some acidic drinks on dentin erosion, using methods of surface profile (SP) analysis and energy-dispersive X-ray fluorescence spectrometry (EDXRF). One hundred standardized dentin slabs obtained from bovine incisor roots were used. Dentin slabs measuring 5x5 mm were ground flat, polished and half of each specimen surface was protected with nail polish. For 60 min, the dentin surfaces were immersed in 50 mL of 5 different drinks (Gatorade®, Del Valle Mais orange juice®, Coca-Cola®, Red Bull® and white wine), 20 blocks in each drink. The pH of each beverage was measured. After the erosive challenge, the nail polish was removed and SP was analyzed. The mineral concentration of dentin surfaces was determined by means of EDXRF. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). SP analysis showed that Red-Bull had the highest erosive potential (p<0.05). EDXRF results exhibited a decrease in phosphate in the groups immersed in Red-Bull, orange juice and white wine (p<0.05), and no significant difference in calcium content between the reference surface and eroded surface. In conclusion, this study demonstrated that all studied beverages promoted erosion on root dentin and Red Bull had the highest erosive potential. There was no correlation between pH of beverages and their erosive potential and only the P content changed after erosive challenge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Ocular prosthesis materials should have specific properties for their indication and durability; therefore, it is important to investigate their physical behaviour when affected by several disinfectants. Objectives: This study evaluated the influence of different disinfecting solutions on the microhardness and surface roughness of acrylic resins for ocular prosthesis. Materials and Methods: Fifty samples simulating ocular prostheses were fabricated with N1 resin and colourless resin and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite (HYC) and 4% chlorhexidine (CHX). Samples were stored in saline solution at 37°C and disinfected during 120 days. Both microhardness and roughness were investigated before, after 60 days and 120 days of disinfection and storage. Microhardness was measured using a microhardner and the roughness with a roughness device. Results: N1 resin showed lower microhardness when compared with colourless resin (p < 0.05). HYC and CHX groups exhibited the highest change of microhardness and roughness values (p < 0.05). An increase in roughness and reduction in microhardness of ocular acrylic resins were observed after both periods of disinfection and storage (p < 0.05). Conclusion: Both disinfection/storage periods affected the microhardness and roughness values of the samples. © 2012 The Gerodontology Society and John Wiley & Sons A/S.