660 resultados para Odontological resins


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The execution of a appropriate odontological surgical treatment for patients with Myocardial Infarction has been based in established protocols for important works in world wide literature during the sixty’s and seventy’s decade, established with a minimum of six months before the noncardiac surgery. The recent advancements in the medical assessment of surgical risk based on the individual analysis of each case with availability of new therapeutic tools in reference to medical or dental treatment, allowing for new procedures that can be used in the execution of safer odontological surgery for each patients. This review of the literature shows the actual tendencies of the treatment of patients with Myocardial Infarction concerning specific care before, during and after surgery based on laboratory evaluation and drug therapy as well as the possibility of surgical treatment before six months post-infarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pigmentation of indirect composite resins has been one of the most common reasons that lead the restorative treatment to failure. The purpose of this study was to investigate the effect of different solutions on color stability of indirect composite resins. Five brands of indirect composite resins were tested: Adoro, Resilab, Cristobal, Sinfony and Epricord. The samples were immerged in eleven solutions (n=10): common liquid foods (coke soft drink, red wine, coffee and orange juice), mounthrinses (Listerine, Oral-B, Colgate Plax and Periogard) and bleaching agents (carbamide peroxide 16%, 7.5% and hydrogen peroxide 38%) and artificial saliva (control group). The color was measured by a spectrophotometer before and after 7, 14 and 21 days of immersion in common liquid foods, after 12, 24, 36 and 60 hours of immersion in mounthrinses and after 7 and 14 days of immersion in bleaching agents. The Cristobal and Adoro resins showed highest values of ΔE statistically significant compared to the others resin brands. Adoro’s ΔE values changed significantly after the immersion process in red wine and coffee and also between periods measured. The resins Cristobal and Sinfony showed the highest values of ΔE after the immersion process in Listerine with difference statistically significant in comparison to control group. Besides, there was difference statistically significant of the ΔE values  for  Cristobal  after  immersion  in hydrogen peroxide 7,5% in comparison to control group. It can be conclude that all the solutions promoted color change on the indirect composite resins. However, ΔE values  are  whitin  the  values clinically acceptable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alveolar bone resorption is continuous throughout the life of edentulous patients, the prosthesis mismatch can generate during speech and chewing. An alternative to this would be to destabilize the denture reline, a maneuver which aims to readjust the denture base to the rim by the addition of a plastic film to the inner surface of the prosthesis material. This procedure may be direct, when performed in the clinic, or indirect when made in prosthetic laboratory. The aim this study is to demonstrate the technical of two reline for denture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The immediate complete denture is a prostheses made prior to teeth extraction, that aims to re-establish the patient aesthetics and function immediately after the removal of the remaining teeth. The objective of this paper is to report the technical procedures during the manufacture of immediate prosthesis. The study reports the clinical steps prior to teeth extraction as well as the surgical and maintenance procedures. The immediate complete denture is a viable rehabilitation method, especially to restore patients’ self-esteem, aesthetics and function promptly. An accurate planning and manufactory beholds better results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Indirect dental composites may have adequate clinical performance. However, the literature is scarce regarding indirect composite resins and these solutions should be considered to maintain their properties. The aim of the study was to evaluate the influence of beverages, mouthwashes and bleaching agents on the hardness of indirect composite resins. Methods: Five different brands of indirect composite resins were evaluated: Adoro, Resilab, Cristobal, Sinfony and Epricord. Ten specimens of each brand were immersed in eleven different solutions: four mouthwashes (Listerine, Oral-B, Plax, Periogard), four beverages (coke soft drink, red wine, coffee, orange juice), three dental bleaching agents (16% peroxide of carbamide, 7.5% and 38% peroxide of hydrogen) and artificial saliva (control group). The Knoop hardness was measured before (baseline) and after 12, 24, 36 and 60 hours of immersion in mouthwashes; after 7, 14 and 21 days of immersion in beverages and after 7 and 14 days of immersion in dental bleaching agents. The results were analyzed using 3-way repeated measures ANOVA and Tukey’s test (p<0.05). Results: All resins presented significant decrease on hardness values after immersion process whereas this reduction was higher for Resilab and Sinfony. The latter exhibited the lowest initial values of hardness while Cristobol resin presented the highest hardness values. The mouthwashes promoted a significant decrease in the hardness of specimens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eye loss results on facial asymmetry compromising its aesthetics. Ocular prostheses are important to re-establish aesthetics; protect the anophthalmic cavity; recover function such as the redirection of lachrymatory liquid; and reintegrate the patient to society. The aim of this study was to describe a case report, demonstrating clinical and laboratorial procedures for confection of ocular prostheses and highlighting their advantages. A female patient was afflicted by toxoplasmosis, which led to the loss of her eye. An eye visceration was performed. The patient reported no previous use of ocular prosthesis. A PMMA ocular prosthesis was manufactured restoring patient’s aesthetic and facial contour. The patient was satisfied with the treatment. Therefore the present study has shown that PMMA ocular prosthesis is able to restore facial aesthetics and can be a safe and satisfactory alternative for patients that have lost their eyes due to toxoplasmosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the opacity of the polymethylmethacrylate for ocular prosthesis using an ocular button, a colorless resin for the ocular prostheses, and 4 brands of acrylic colorless resin in the function of weathering (0, 504, or 1008 h) and thickness (1 and 3.5 mm). One hundred twenty specimens were confectioned (made) and allocated into 12 groups (n = 10). Opacity analysis was carried out with a spectrophotometer of visible ultraviolet reflection before and after weathering by 504 and 1008 hours. Data for the opacity were expressed in ΔE. Data were then analyzed statistically by analysis of variance and the Tukey test (P < 0.01). The data demonstrated statistically significant differences; manufactured ocular button (ΔE = 47.4) and the resin Vipi Cril (ΔE = 38.11) presented greater and minor values of opacity, respectively. The weathering showed statistical difference among times (0 h, ΔE = 36.32; 504 h, ΔE = 39.98; and 1008 h, ΔE = 43.9). Ocular button and evaluated resins presented greater values of opacity when presented in 3.5 mm in thickness. The values of opacity increased with the progression of the time of weathering, independent of the evaluated material and the thickness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: The aim of this study is to present a clinical case in which an occlusal matrix device was used in a patient who needed to restore a posterior tooth. MATERIAL AND METHODS: A direct duplicate occlusal appliance was used (biteperf) in a patient who needed an occlusal restoration in two posterior teeth. RESULTS: Using the matrix helps having fast and accurate reproduction of the original anatomical details of the occlusal surface. The final result surprised with the presented restoration in terms of esthetic quality, despite the simplicity of the technique. CONCLUSION: Posterior teeth with initial lesions were confined to the occlusal surface of anatomically complex or fissured anatomy with or without signs of proximal caries wich are ideal candidates for this technique. The overlying enamel surface must be relatively intact; lesions of hidden or occult caries. CLINICAL SIGNIFICANCE: The aesthetic and time-saving benefits of the occlusal device (biteperf) are immediately clear. The matrix allows the fast and accurate reproduction of the anatomic details of the original occlusal surface of the tooth. The professionals who lack an artistic penchant and marked manual ability will be able to carry out excellent posterior resin composite restorations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Color stability of restorative materials is essential for longevity of esthetic composite restoration over time. The aim of this investigation was assess the effect of prior water immersion on the color stability of a composite resin to red wine staining. Seventy disccshaped specimens (6mm x 1.5mm) were carried out and randomized in 7 groups (n = 10), according to distilled water immersion time at 0 (control), 24, 48, 72,120,192, and 240 h. Baseline color was measured according to the ciel*a*b* system using a reflection spectrophotometer(uvc2450, shimadzu).After that, the specimens were storage in red wine for 7 days. Color difference (∆e) after aging was calculated based on the color coordinates before(baseline) and after storage period.Data were subjected to onecway anova(alpha=0.05).The different times of immersion in.Water before to the red wine storage showed similar behavior on the color stability, without statistical difference compared to control group, immersed directly in the wine(p=0.7057).The previous water uptake of composite resin evaluated did not decrease the susceptibility to red wine staining.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cerebral paralysis is a chronic illness that affects the central nervous system. In this article the author describes the techniques used at CAOE (Odontological Center for Assistance to patients with special needs) to restraint CP patients during dental treatment, because they present some pathological reflexes which interfere in their odontological assistance. Also it shows how to perform a special physical restraint and how to keep the mouth open by using simple tools including a homemade one. All the devices used during the dental treatment in cerebral palsy patients, such as the physical restraint with bands or sheet to wrap them up, cylindrical pad or cushion made of a soft material, or simple tools including a homemade one to keep the mouth open are usually and safely used in CAOE. All these simple devices are necessary, because there are no available funds for the acquisition of expensive material or equipment. Despite of a shortage of resources we can easily and efficiently assist these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case report of a patient who presents as chief complaint presence of stained restorations in the anterior teeth. After analysis and discussion of the clinical therapeutic approaches to be adopted, it was observed the presence of type class IV restorations on teeth 11 and 21, due to an oblique coronal fracture in the past. But the patient was not satisfied with the aesthetic result, then where was planned the realization of the removal of the restorations, for subsequently be used direct restorative materials for the correction of form, function and esthetics. The final result showed that the restorations were able to return the form, function and aesthetic dental, thereby evidencing the proven development of restorative dentistry in the solution of aesthetic problems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to evaluate the effect of thermocycling on the color variation of three different composite resins . We studied was Resin Enamel on 3 levels : ( Esthetic X , Opallis and Venus ) ; Resin Dentin in three levels : ( Esthetic X , Opallis and Venus ) and Thermocycling on level 1 : ( 3,000 cycles ) ; variable was the change of color gauged by spectrophotometry . 60 specimens , subdivided into 6 groups were made : GI - Esthetic X Enamel ; GII - Esthetic X dentin ; GIII - Opallis Enamel ; GIV - Opallis dentin ; GV - Enamel and GVI Venus - Venus dentin . The specimens were prepared with a matrix to standardize samples . The inserts of incrementally resins and polymerized with a halogen light Ultralux unit ( Dabi Atlante , Brazil ) with a power of 450mW / cm ² . After fabrication , underwent color reading with a UV Visible Spectrophotometer reflection , UV -2450 ( Shimadzu , Kyoto , Japan ) , with the changes calculated by the system CIE L * a * b * . Then isolates were stored in artificial saliva at 35 ° C ± 2 ° C during 3 months containers being subjected to the effects of thermal cycling for 3000 cycles over the range of 5C to 55C . Again subjected to chromatic evaluation. For the analysis of the results of color change of the studied resins was applied ANOVA two factors at 5 % . The results showed a statistically equal resins enamel GI and GV ( p = 0.79 ) ; the same was not observed for GI and G III resins , where the color change was higher for resin G III ( p = 0.0000002 ) . The same was observed between G III and GV , where the resin enamel G III showed a statistically superior to the color change ( p = 0.0000005 ) Average . Resins to dentin was there a statistical equality between the materials studied . We conclude that the resins studied change in color and resin enamel G III was the most suffered major color changes after aging by thermocycling .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A healthy and attractive smile is very valued in today s society. Yet this requires better aesthetic and cosmetic solutions from dental surgeons.The present paper presents a case report of diastema closure using an association of tooth movement induced by orthodontic elastics,dental cosmetics and resin-bonded prosthesis. The female patient L.B.A.J., aged 19 years, visited the Integrated Clinic of Araçatuba DentalSchool UNESP mainly complaining of missing teeth and poor esthetics. After anamnesis, clinical and radiographic examination revealedhypodontia of the maxillary right and left first premolars, abnormal maxillary right lateral incisor shape and diastema between the maxillaryright lateral incisor and canine and between the maxillary left lateral incisor and canine. Planning was done which included indication ofdiastema closure with composite resin restoration and metal-free resin-bonded prosthesis, with a structure made of Vectris (Ivoclar VivadentInc., Amherst, NT, USA). The option for dental cosmetics associated with resin-bonded prosthesis after movement with orthodontic elasticsresulted in an excellent aesthetic outcome of low cost and short treatment duration.Indexing terms: composite resins; diastema; fixed resin bonded partial denture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clinical performance of composite resins depends largely on their mechanical properties,and those are influenced by several factors,such as the light-curing mode. The purpose of this study was to evaluate the influence of different light sources on degree of conversion(DC), Knoop hardness(KHN) and plasticization(P) of a composite resin. Disc-shaped specimens (5 x 2 mm) of Esthet-X(Dentsply) methacrylate-based microhybrid composite were light-cured using quartz-tungsten-halogen (QTH) Optilight Plus(Gnatus) or light-emitting diode(LED) Ultraled(Dabi Atlante) curing units at 400 and 340 mW/cm2 of irradiance, respectively. After 24 h, absorption spectra of composite were obtained using Nexus 670(Nicolet)FT-IR spectrometer in order to calculate the DC.The KHN was measured in the HMV-2000(Shimadzu) microhardness tester under 50 g loads for 15 s, and P was evaluated by percentage reductio of hardness after 24 h of alcohol storage. Data were subjected to t-Student test(alpha=0.05).QTH device showed lower P and higher KHN$ than LED (p<0.05), and no difference between the light-curing units was found for DC (p>0.05). The halogen-curing unit with higher irradiance promoted higher KHN and lower softening in alcohol than LED.