128 resultados para shunt pulmonar
Resumo:
Chronic obstructive pulmonary disease (COPD) is considered the forth cause of death in the world. The present review summarizes the epidemiologic and risk factors to the disease. Emphasizing the diagnostic, pulmonary function, radiological alterations and blood gases. According to the current guideline recommendations, the authors reviewed the classification and treatment. © Copyright Moreira Jr. Editora. Todos os direitos reservados.
Resumo:
BAKGROUND AND OBJECTIVES: Negative pressure pulmonary edema has been defined as non-cardiogenic edema, with transudation of fluid to the interstitial space of the lungs due to an increase in negative intrathoracic pressure secondary to obstruction of the upper airways. This is the case of a healthy patient who underwent general anesthesia and developed acute pulmonary edema after extubation. CASE REPORT: A 23-year old female patient, physical status ASA II, underwent gynecologic videolaparoscopy under general anesthesia. The procedure lasted 3 hours without intercurrence. After extubation the patient developed laryngeal spasm and reduction in oxygen saturation. The patient improved after placement of an oral cannula and administration of oxygen under positive pressure with a face mask. Once the patient was stable she was transferred to the recovery room where, shortly after her arrival, she developed acute pulmonary edema with elimination of bloody serous secretion. Treatment consisted of elevation of the head, administration of oxygen via a face mask, furosemide and fluid restriction. Chest X-ray was compatible with acute pulmonary edema and normal cardiac area. Electrocardiogram (ECG), echocardiogram and cardiac enzymes were normal. The condition of the patient improved and she was discharged from the hospital the following day, asymptomatic. CONCLUSIONS: Acute pulmonary edema associated with obstruction of the upper airways can aggravate surgical procedures with low morbidity, affecting mainly young patients. Early treatment should be instituted because it has a fast evolution and, in most cases, resolves without lasting damages. © Sociedade Brasileira de Anestesiologia, 2008.
Resumo:
Considering the Conservative Power Theory (CPT), this paper proposes some novel compensation strategies for shunt passive or active devices. The CPT current decompositions result in several current terms, which are associated with specific physical phenomena (average power consumption P, energy storage Q, load and source distortion D, unbalances N). These current components were used in this work for the definition of different current compensators, which can be selective in terms of minimizing particular disturbing effects. Compensation strategies for single and three-phase four-wire circuits have also been considered. Simulation results have been demonstrated in order to validate the possibilities and performance of the proposed strategies. © 2010 IEEE.
Resumo:
A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper. © 2010 IOP Publishing Ltd.
Resumo:
The present review summarizes the clinical aspects, diagnostics criteria and treatment of Chronic Obstructive Pulmonary Disease (COPD). Besides, will be reviewed the systemic manifestations associated with COPD and its clinical relevance in the patient's follow up. © Copyright Moreira Jr. Editora.
Resumo:
Considering the operation of shunt active compensators, such as active power filters, this paper proposes possible compensation strategies by means of the recent formulation of the Conservative Power Theory (CPT). The CPT current's decomposition results in several current components, which are associated with specific load characteristics (power transfer, energy storage, unbalances and/or non linearities). These current components are used for the definition of different compensation strategies, which can be selective in terms of minimizing particular disturbing effects. In order to validate the applicability of these new compensation strategies, simulation and experimental results for three-phase four-wire systems are presented. © 2011 IEEE.
Resumo:
The morphologically undivided ventricle of the heart in non-crocodilian reptiles permits the mixing of oxygen-rich blood returning from the lungs and oxygen-poor blood from the systemic circulation. A possible functional significance for this intra-cardiac shunt has been debated for almost a century. Unilateral left vagotomy rendered the single effective pulmonary artery of the South American rattlesnake, Crotalus durissus, unable to adjust the magnitude of blood flow to the lung. The higher constant perfusion of the lung circulation and the incapability of adjusting the right-left shunt in left-denervated snakes persisted over time, providing a unique model for investigation of the long-term consequences of cardiac shunting in a squamate. Oxygen uptake recorded at rest and during spontaneous and forced activity was not affected by removing control of the cardiac shunt. Furthermore, metabolic rate and energetic balance during the post-prandial metabolic increment, plus the food conversion efficiency and growth rate, were all similarly unaffected. These results show that control of cardiac shunting is not associated with a clear functional advantage in adjusting metabolic rate, effectiveness of digestion or growth rates. © 2013. Published by The Company of Biologists Ltd.
Resumo:
Based on the framework of the Conservative Power Theory (CPT), this paper proposes some compensation strategies for shunt current compensators. CPT current decompositions result in several current-related terms associated with specific load characteristics, such as power consumption, energy storage, unbalances and load nonlinearities. These current components are decoupled (orthogonal) from each other and are used here to define different compensation strategies, which can be selective in minimizing particular effects of disturbing loads. Compensation strategies for single- and three-phase four-wire circuits are also considered. Simulated and experimental results are described to validate the possibilities and performance of the proposed strategies. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Fisioterapia - FCT