In the treatment plans in conventional Proton therapy are considered only the elastic interactions of protons with electrons and/or nuclei, it means, mainly ionization and coulomb excitation processes. As the energy needed to reach the deep tumors should be of several hundred of MeVs, certainly the nuclear inelastic channels are open. Only some previous studies of the contribution of these processes in the full dose have been made towards targets composed of water. In this study will be presented the results of the simulation of the processes of interaction of beams of protons in the range of 100-200 MeV of energy with a cylindrical phantom composed by striated muscle (ICRU), emphasizing in the contribution to total dose due to the deposition of energy by secondary particles alpha (α), deuterium (2H), tritium (3H), neutron (n) and hélio3 (3He), originated by nuclear inelastic processes. The simulations were performed by using the method of Monte Carlo, via the computer code MCNPX v2.50 (Monte Carlo N-Particle eXtended). The results will be shown demonstrated through the graphics of the deposited dose with or without nuclear interaction, the percentual of dose deposited by secondary particles, the radial dispersion of neutrons, as well as the multiplicity of secondary particles

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project has several objectives: To determine medium values and variations of the density, porosity, humidity, shrinkage volume and the coefficient of mass attenuation of gamma radiation of 59,6 keV of the radioisotope 241Am, using samples of equine radio, in growth and adult. The samples of bones were supplied by the Department of Pathology of University of Veterinary Medicine and Zootechnics - UNESP campus Botucatu. Bones of the paws front left of two males were used. Of each bone ten samples were removed. Those samples were prepared to just obtain compact bony fabric, being submitted to the rehearsal of determination of the density by the immersion method in water and determination of the coefficient attenuation lineal for the method of attenuation of the radiation of the 241Am, also obtaining your humidity content. Still, they were obtained new samples starting from the ground samples and verified the density of the particles present in that, obtaining the medium value of the coefficient of mass attenuation. The results showed the medium values and significant statistical variations of the density, porosity, humidity, shrinkage volume and coefficient of mass attenuation of gamma radiation of 59, 6 keV of the radioisotope 241Am in the samples, establishing some relationships between of the certain physical parameters with biological aspects and possible existent influences between them

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In proton therapy, the deposition of secondary particles energy originated by nuclear inelastic process (n, 2H, 3H, 3He and α) has a contribution in the total dose that deserves to be discussed. In calculations of plans implemented for routine treatment, the paid dose is calculated whereas the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered. There are only estimates for pure materials or simple composition (water, for example), because of the difficulty of processing targets consisting of different materials. For this project, we use the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) to present results of the contribution to the total dose of secondary particles. In this work, it was implemented a cylindrical phantom composed by cortical bone, for proton beams between 100 and 200 MeV. With the results obtained, it was possible to generate graphics to analyze: the dose deposition relation with and without nuclear interaction, the multiplicity and percentage of deposited dose for each secondary particle and a radial dispersion of neutrons in the material

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oral administration is widely accepted route for drug delivery and solid dosage forms are commonly employed. The variation of absorption profiles along the human gastrointestinal tract (GIT) and the ability to target drugs by adequate dosage forms to distinct sites is the challenge in the pharmaceutical development of solid dosage forms. AC Biosusceptometry (ACB) is a technique that deserves consideration due to its features, accuracy of results and versatility. The purpose of this work was to evaluate, by employing the AC Biosusceptometer, the rate of swelling of systems matrices consisting of hydrophilic polymer (hydroxypropyl methyl cellulose) and magnetic material. Matrices tablets were evaluated in vitro to a more detailed analysis of kinetics of swelling, in addition to the study and application of mathematical models to correlate the magnetic area variation and the water uptake. All the procedures for qualitative and quantitative analysis of digital signals as well as the magnetic images processing were performed in MatLab® (Mathworks Inc.). ACB technique proved to be useful towards estimating the swelling properties of hydrophilic matrices in vitro, showing a promising capacity for further analyses involving dissolution test and in vivo studies, supporting their innovative potential pharmaceutical applications

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Communities are present on physical, chemical and biological systems and their identification is fundamental for the comprehension of the behavior of these systems. Recently, available data related to complex networks have grown exponentially, demanding more computational power. The Graphical Processing Unit (GPU) is a cost effective alternative suitable for this purpose. We investigate the convenience of this for network science by proposing a GPU based implementation of Newman community detection algorithm. We showed that the processing time of matrix multiplications of GPUs grow slower than CPUs in relation to the matrix size. It was proven, thus, that GPU processing power is a viable solution for community dentification simulation that demand high computational power. Our implementation was tested on an integrated biological network for the bacterium Escherichia coli

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho foi analisada a resolução espacial de sensores de Biossusceptometria AC (BAC) correlacionando dois métodos consagrados em análise de resolução, a Função de Transferência Modulada (do inglês MTF) e a Largura à Meia Altura (FWHM) da Função de Espalhamento Pontual (PSF). A partir da aquisição da PSF do sistema, foi possível quantificar a resolução dos sensores pelos dois métodos. Foram analisados sensores de diferentes diâmetros para a obtenção da correlação entre os dois métodos. Foi variada também a corrente, indiretamente, pela variação de voltagem de excitação. Com estas metodologias foi possível avaliar a resolução de maneira pontual dos sensores, sendo possível otimizar a utilização dos sensores de acordo com a medida a ser realizada

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Boron Neutron Capture Therapy (BNCT), based on the 10B(n,α)7Li reaction, represents a promising modality for the treatment of cancers that are resistents to conventional treatments. So, it is necessary to find drugs (boron compounds) with high selectivity for each type of cancer, the neutrons source should be well characterized and the rate of 10B(n,α)7Li reaction should be measured with great accuracy as possible. This study aimed to develop a method for manufacturing thin films of boron, for measure the 10B(n,α)7Li reaction, and analyze the uniformity of the films. Five thin films of boron were manufactured with three different concentrations of boric acid, heated to transform the acid in boron, irradiated with thermic neutrons coupled to CR-39 detectors, in BNCT line at the reactor IEA-R1 IPEN/CNEN, São Paulo. After the irradiation, the detectors were chemically attacked with NaOH to reveal the tracks. The methodology presented is effective because it resulted in deposition of boron as thin film enabling the quantitative analysis of 10B(n,α)7Li reaction. The analysis of the uniformity of density of the induced tracks in CR-39 shows that, in most of the films, there is no uniformity in surface distribution of boron, but when the film is divided, we obtain some uniform sectors

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mass spectrometry is an analytical technique widely used in several areas of academic research. It allows the knowledge of the information about the micro-world of atoms leading to significant advances in science today. The analysis of stable isotopes of carbon, hydrogen, oxygen, nitrogen and sulfur, also known as bio-elements, shows itself as a major area of interest in using the proposed method. The development of techniques and equipment coupled with mass spectrometry promises to deliver even greater progress in this field, in particular, for the biological sciences and related areas. The pyrolytic method in reduction of organic compounds at high temperatures provides simultaneous isotopic analysis of bio-elements H and O, by the gases released, H2 and CO after the pyrolitic process, significantly reducing analysis time and the amount of material to sample. This paper presents a review of mass spectrometry with its basic principles of operation, and pyrolytic method for reducing compounds at temperatures above 1400 ° C for isotopic analysis of bio-elements

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The contribution of the total dose due to deposition of secondary energy particles caused by nuclear inelastic processes (n, 2H, 3H, 3He and  ) in proton therapy is an opened problem and in discussion. In the calculations of plans implemented for routine treatment, the paid dose is calculated whereas that the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered, mainly due to the difficulty of processing targets consisting of various materials. In this sense, there are only estimates for pure materials or simple composition (water, for example).This work presents the results of simulations by the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) of the contribution to the total dose of secondary particles. The study was implemented in a cylindrical phantom composed by compact bone, for monochromatic beams of protons between 100 and 200 MeV with pencil beam form

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The teaching of hearing physiology requires an knowledge integration of Human Anatomy, Biophysics, more precisely Bioacoustics and Bioelectrogenesis, as well as Neurophysiology. Students present difficulty to build knowledge about functional mechanisms of sound conduction and sensory transduction, especially if the elements are not visible forms, as the middle and inner ear structures. To make the teaching about hearing physiology and sensory perception easier, was produced a set of didactical materials about the subject. At first, a resin model that faithfully describes the anatomical relationship of the ossicles with the tympanic membrane was developed. Subsequently, a second model that, besides illustrates the mechanism of acoustic impedance overcoming, also reveals how acoustic sensorial transduction occurs in inner ear, was designed and produced. In the third didactical model, are visualized, through students interaction, areas of the cerebral cortex that interpret the different sensory modalities. In addition, were created three educational videos about hearing problems and a site on Human Hearing Physiology, available on Institute of Biosciences website. The results of this course conclusion monograph are presented in the form of articles that were submitted to Journal Physics in the School and the Journal of the Nucleus of Teaching

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experimental study in dogs was accomplished to evaluate impedances at the acupuncture points and the relative false points. According to the physics concepts and the Ohm’ Law, an electrical circuit was set up to determine the impedance. This circuit was introduced into three experiments in anesthetized dogs with needles at selected points. In the first two experiments, was applied an alternating tension with 200Hz frequency in the circuit and, in the last experiment, the frequency was increased to 10kHz, the tensions and electrical currents were measured between every pair of points for the all experiments. The impedances were calculated with the values obtained by experiments. The analysis of impedance values indicated that there is a coherent relation between the results and the applied frequencies in circuit, so just at high frequency condition admits the correct measurement of total impedance, therefore the last experiment gave the result which agreed with the theory, that the impedances at acupuncture points are lower than the impedances at false points

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The plasma represents a average of the information referring biochemists to the physiology of the organism as a whole, therefore it indirectly or directly interacts with all tissues of the body. In such a way the plasma can be considered as a metabolic “soup”. Using the Nuclear Magnetic Resonance Spectroscopy sanguineous plasma spectra had been generated and using deconvolution techniques it was possible to know the contribution of the albumin for the formation of the spectra of the sanguineous plasma

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program