120 resultados para maximum osmotic potential at saturation point
Resumo:
Pós-graduação em Saúde Coletiva - FMB
Resumo:
The objective of this study was to evaluate the phytotoxicity of Solanum aculeatissimum Jacq. leaves ethanolic extract in seeds germination, development and fixation of Lactuca sativa seedlings. The same study also aimed to assess the mitotic index of lettuce roots meristematic cells, quantification of phenols and total flavonoids and triage by mean of phytochemical testing of the main secondary metabolites classes. Bioassays of germination, development of root and hypocotyl were carried out in Petri dishes using achenes of Lactuca sativa L. cv. 'Grand Rapids' (lettuce). Concomitantly, were evaluated the physico-chemical characteristics (pH, osmotic potential and electrical conductivity), mitotic index, quantification of total phenols and flavonoids and determination of phytochemical profile of the treatments extract. The results obtained in the bioassays demonstrate that the ethanol extract of S. aculeatissimuma presents phytotoxic potential in the development of lettuce seedlings, given that the concentration of 20 mg/ml showed greater inhibition (41% of germination). The extract contains significant amounts of antioxidants, total flavonoid and phenols, where the concentration 1000µg/mL showed higher values (86.50%). Furthermore, it was possible to observe the presence of compounds with allelopathic activity in the phytochemical screening test as coumarins, tannins, terpenes, flavonoids and alkaloids. Given the above it is clear that the ethanolic extract of S. aculeatissimum presents allelopathic substances with phytotoxic activity that can affect the germination and development of other plant species in their natural environment.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Saúde Coletiva - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
High Curie point CaBi2Nb2O9 thin films: A potential candidate for lead-free thin-film piezoelectrics
Resumo:
CaBi2Nb2O9 (CBNO) thin films deposited on platinum coated silicon substrates by the polymeric precursor method exhibited good structural, dielectric, and piezoelectric characteristics. Capacitance-voltage measurements indicated good ferroelectric polarization switching characteristics. Remanent polarization and drive voltage values were 4.2 mu C/cm(2) and 1.7 V for a maximum applied voltage of 10 V. The film has a piezoelectric coefficient d(33) equal to 60 pm/V, current density of 0.7 mu A/cm(2), and Curie temperature of 940 degrees C. The polar-axis-oriented CBNO is a promising candidate for use in lead-free high Curie point in ferroelectric and piezoelectric devices. (c) 2006 American Institute of Physics.
Resumo:
The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
There are point interactions in one dimension that can be interpreted as self-adjoint extensions (SAEs) of the kinetic energy [KE] operator. Here, we report the results obtained in two recent papers cited in [1]. In the first, we consider point interactions in one dimension in the form of the Fermi pseudo-potential, in one and two-channel cases. In the second, we consider a new type of point interactions that are self-adjoint and effectively energy-dependent. © 2005 American Institute of Physics.
Resumo:
The operational details of the apparent electrical conductivity (ECa) sensor manufactured by Veris Technologies have been extensively documented in literature reports, but the geographical distribution of these research studies indicate a strong regional concentration in the US Mid-west and Southern states. The agricultural lands of these states diverge significantly to the soil conditions and water regime of irrigated land in the US South-western states such as Arizona where there is no previous research reports of the use of this particular sensor. The objectives of the present study were to analyze the performance of this sensor under the conditions of typical soils in irrigated farms of Central Arizona. We tested under static conditions the performance of the sensor on three soils of contrasting texture. Observations were collected as time series data as soil moisture changed from saturation to permanent wilting point. Observations were repeated at the hours of lowest and highest temperatures. In addition, this study included soil penetration resistance and salinity determinations. Preliminary results indicate that soil temperature of the upper layer caused the most dynamic change in the sensor output. The ECa curves of the three soil textures tested had well defined distinctive characteristics. Final multivariate analysis is pending.
Resumo:
Maximum Power Point tracking (MPPT) in photovoltaic (PV) systems may be achieved by controlling either the voltage or current of the PV device. There is no consensus in the technical literature about how is the best choice. This paper provides a comparative analysis performance among current and voltage control using two different MPPT strategies: the perturb and observe (P&O) and the incremental conductance techniques. © 2011 IEEE.
Resumo:
This paper presents evaluations among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic panel (PV) (Tracking Factor - TF) in relation to the available power, PV voltage ripple, dynamic response and use of sensors. Using MatLab/Simulink® and DSpace platforms, a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented and a contribution in the implementation of the IC algorithm is performed and called IC based on PI. Moreover, the dynamic response and the tracking factor are also evaluated using a Friendly User Interface, which is capable of online program power curves and compute the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2011 IEEE.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Health risks in the effluents of seven swine abattoirs and of seven poultry abattoirs were evaluated with regard to environment degradation and to dissemination of pathogenic microorganisms during the rainy and dry seasons. Supply-water samples from affluents and effluents of the treatment systems at different sites within the abattoir processing system were analysed. Similarly, water samples from the three recipient sites (emission point, 100 m upstream, 100 m downstream) were also analysed. Temperature, free residual chlorine (FRC), total coliform bacteria, Escherichia coli, enterococci, identification and serotyping of salmonellae were assessed. Scalding is the most significant stage in the slaughtering chain (P<0.05) when temperature is taken into account. Temperatures Lit effluents and at the sampled sites in the water bodies accorded to state and federal legislation standards. Supply waters did not meet the standards for FRC and microbial count standards according to the Ministry of Health and within limits imposed by the Industrial and Sanitary Inspection Regulations for Animal Products. Feather plucking and evisceration in Poultry slaughter and the cleansing of carcasses and facilities in Poultry and swine slaughtering had the highest contamination impact. The three loci at the water bodies were above the microbiological standards for classes II and III sites, in conformity with Law 8468 of the state of São Paulo, Brazil and Conama. Salmonella was found at several sites during slaughter, at both types of abattoirs, including in the effluent treatment system. This showed that these sites were the dissemination sources of the microorganism.