112 resultados para mammography screening


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical methods for sweetpotato, cassava and maize were developed. In orange and salmon-fleshed sweetpotatoes, (all-E)-beta-carotene predominated and results of spectrophotometric screening and HPLC quantification did not differ significantly. In yellow-fleshed sweetpotato and cassava, however, spectrophotometric screening overestimated the HPLC values because of the presence of several minor carotenoids. Aside from (all-E)-beta-carotene, Z-isomers were present in cassava in appreciable amounts. For both crops, extraction with acetone or tetrahydrofuran: methanol. (1: 1), using a mortar and pestle or a Polytron homogenizer, gave equivalent results. Rehydration of dry maize at room temperature for 30 min or at 85 degrees C for 5, 10 or 15 min gave equivalent results. Concentrations obtained with the C18 and C30 columns did not differ significantly for zeaxanthin, lutein, beta-cryptoxanthin and beta-carotene in the all-E-configuration, but their Z-isomers were difficult to locate in the chromatogram obtained with the C30 column. Extraction with tetrahydrofuran:methanol (1:1) gave significantly lower results for zeaxanthin and lutein. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a set of Brazilian commercial gasoline representative samples from São Paulo State, selected by HCA, plus six samples obtained directly from refineries were analysed by a high-sensitive gas chromatographic (GC) method ASTM D6733. The levels of saturated hydrocarbons and anhydrous ethanol obtained by GC were correlated with the quality obtained from Brazilian Government Petroleum, Natural Gas and Biofuels Agency (ANP) specifications through exploratory analysis (HCA and PCA). This correlation showed that the GC method, together with HCA and PCA, could be employed as a screening technique to determine compliance with the prescribed legal standards of Brazilian gasoline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated mutations in the genes katG, inhA (regulatory and structural regions), and kasA and the oxyR-ahpC intergenic region of 97 isoniazid (INH)-resistant and 60 INH-susceptible Mycobacterium tuberculosis isolates obtained in two states in Brazil: São Paulo and Parana. PCR-single-strand conformational polymorphism (PCR-SSCP) was evaluated for screening mutations in regions of prevalence, including codons 315 and 463 of katG, the regulatory region and codons 16 and 94 of inhA, kasA, and the oxyR-ahpC intergenic region. DNA sequencing of PCR amplicons was performed for all isolates with altered PCR-SSCP profiles. Mutations in katG were found in 83 (85.6%) of the 97 INH-resistant isolates, including mutations in codon 315 that occurred in 60 (61.9%) of the INH-resistant isolates and 23 previously unreported katG mutations. Mutations in the inhA promoter region occurred in 25 (25.8%) of the INH-resistant isolates; 6.2% of the isolates had inhA structural gene mutations, and 10.3% had mutations in the oxyR-ahpC intergenic region (one, nucleotide -48, previously unreported). Polymorphisms in the kasA gene occurred in both INH-resistant and INH-susceptible isolates. The most frequent polymorphism encoded a G(269)A substitution. Although KatG(315) substitutions are predominant, novel mutations also appear to be responsible for INH resistance in the two states in Brazil. Since ca. 90.7% of the INH-resistant isolates had mutations identified by SSCP electrophoresis, this method may be a useful genotypic screen for INH resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 2400 samples of commercial Brazilian C gasoline were collected over a 6-month period from different gas stations in the São Paulo state, Brazil, and analysed with respect to 12 physicochemical parameters according to regulation 309 of the Brazilian Government Petroleum, Natural Gas and Biofuels Agency (ANP). The percentages (v/v) of hydrocarbons (olefins, aromatics and saturated) were also determined. Hierarchical cluster analysis (HCA) was employed to select 150 representative samples that exhibited least similarity on the basis of their physicochemical parameters and hydrocarbon compositions. The chromatographic profiles of the selected samples were measured by gas chromatography with flame ionisation detection and analysed using soft independent modelling of class analogy (SIMCA) method in order to create a classification scheme to identify conform gasolines according to ANP 309 regulation. Following the optimisation of the SIMCA algorithm, it was possible to classify correctly 96% of the commercial gasoline samples present in the training set of 100. In order to check the quality of the model, an external group of 50 gasoline samples (the prediction set) were analysed and the developed SIMCA model classified 94% of these correctly. The developed chemometric method is recommended for screening commercial gasoline quality and detection of potential adulteration. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obstructive sleep apnea (OSA) is a respiratory disease characterized by the collapse of the extrathoracic airway and has important social implications related to accidents and cardiovascular risk. The main objective of the present study was to investigate whether the drop in expiratory flow and the volume expired in 0.2 s during the application of negative expiratory pressure (NEP) are associated with the presence and severity of OSA in a population of professional interstate bus drivers who travel medium and long distances.Methods/Design: An observational, analytic study will be carried out involving adult male subjects of an interstate bus company. Those who agree to participate will undergo a detailed patient history, physical examination involving determination of blood pressure, anthropometric data, circumference measurements (hips, waist and neck), tonsils and Mallampati index. Moreover, specific questionnaires addressing sleep apnea and excessive daytime sleepiness will be administered. Data acquisition will be completely anonymous. Following the medical examination, the participants will perform a spirometry, NEP test and standard overnight polysomnography. The NEP test is performed through the administration of negative pressure at the mouth during expiration. This is a practical test performed while awake and requires little cooperation from the subject. In the absence of expiratory flow limitation, the increase in the pressure gradient between the alveoli and open upper airway caused by NEP results in an increase in expiratory flow.Discussion: Despite the abundance of scientific evidence, OSA is still underdiagnosed in the general population. In addition, diagnostic procedures are expensive, and predictive criteria are still unsatisfactory. Because increased upper airway collapsibility is one of the main determinants of OSA, the response to the application of NEP could be a predictor of this disorder. With the enrollment of this study protocol, the expectation is to encounter predictive NEP values for different degrees of OSA in order to contribute toward an early diagnosis of this condition and reduce its impact and complications among commercial interstate bus drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to develop and apply the direct immunohistochemistry (D-IHC) assay to search for turkey coronavirus (TCoV) antigens in formalin-fixed embedded-paraffin tissues by the use of biotin-labeled polyclonal antibody. Twenty-eight-day-old embryonated turkey eggs (n = 50) were inoculated with TCoV-purified virus, and 3 d after inoculation, sections from ileum, ileum-cecal junction, and ceca were harvested, fixed in neutral formalin, and embedded in paraffin blocks and used as positive control. In addition, a total of 100 field samples from ileum, ileum-cecal junction, and ceca, collected from 30 to 45-d-old turkeys poults experiencing an outbreak of acute enteritis, were used to search for TCoV by the same D-IHC. All results were compared with those obtained by conventional RT-PCR and indirect fluorescent antibody assay (IFA) for all tested samples. Turkey coronavirus was detected in experimentally infected embryo tissues and also in field samples in 100% of ileum-cecal junction and ceca by the 3 detection procedures. With IFA as a reference assay, sensitivity and specificity of D-IHC were 98 and 58%, whereas sensitivity and specificity of reverse transcription-PCR were 96 and 66%, calculated from the total of tested samples from experimental infection. Each of the examined procedures was highly specific (D-IHC, 93%; RT-PCR, 90%), sensitive (D-IHC, 85%; RT-PCR, 86%), and agreement of both D-IHC and RT-PCR was 99 and 100%, respectively, compared with IFA results obtained from all the field samples. These findings demonstrated the utility of D-IHC for direct detection of TCoV from field samples and considering the sensitivity and specificity found here, can be used as an alternative technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for a screening program for haemoglobinopathies in a starch agar gel mixed with saponin is presented. Normal and abnormal blood containing haemoglobins S, C, I, M Boston, D Punjab, beta thalassaemia major and beta thalassaemia minor, were applied, in a tray with the capacity for 100 samples. The electrophoresis was performed in 45 min using 300 V. This method offers special advantages for the examination of a large number of samples, using a small amount of whole blood and without the previous preparation of haemoglobin solution.