83 resultados para impulsive loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although traditionally obsessive-compulsive disorder (OCD) and impulse control disorders (ICD) have represented opposing ends of a continuum, recent research has demonstrated a frequent co-occurrence of impulsive and compulsive behaviours, which may contribute to a worse clinical picture of some psychiatric disorders. We hypothesize that individuals with 'impulsive' OCD as characterized by poor insight, low resistance, and reduced control towards their compulsions will have a deteriorative course, greater severity of hoarding and/or symmetry/ordering symptoms, and comorbid ICD and/or substance use disorders (SUD). The sample consisted of 869 individuals with a minimum score of 16 on the Yale-Brown Obsessive Compulsive Scale (Y-BOCS). Of these, 65 had poor insight, low resistance, and reduced control towards compulsions ('poor IRC') and 444 had preserved insight, greater resistance and better control over compulsions ('good IRC'). These two groups were compared on a number of clinical and demographic variables. Individuals with poor IRC were significantly more likely to have a deteriorative course (p < 0.001), longer duration of obsessions (p = 0.017), greater severity of symmetry/ordering (p < 0.001), contamination/cleaning (p < 0.001) and hoarding (p = 0.002) symptoms, and comorbid intermittent explosive disorder (p = 0.026), trichotillomania (p = 0.014) and compulsive buying (p = 0.040). Regression analysis revealed that duration of obsessions (p = 0.037) and hoarding severity (p = 0.005) were significant predictors of poor IRC. In the absence of specific measures for impulsivity in OCD, the study highlights the utility of simple measures such as insight, resistance and control over compulsions as a phenotypic marker of a subgroup of OCD with impulsive features demonstrating poor clinical outcome. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we introduce the concept of MP-pseudoinvexity for general nonlinear impulsive optimal control problems whose dynamics are specified by measure driven control equations. This is a general paradigm in that, both the absolutely continuous and singular components of the dynamics depend on both the state and the control variables. The key result consists in showing the sufficiency for optimality of the MP-pseudoinvexity. It is proved that, if this property holds, then every process satisfying the maximum principle is an optimal one. This result is obtained in the context of a proper solution concept that will be presented and discussed. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For intricate automotive systems that enclose several components, such as gearboxes, an important aspect of the design is defining the correct assembly parameters. A proper assembly can ensure optimized operating conditions and therefore the components can achieve a longer life. In the case of the support bearings applied to front-axle lightweight differentials, the assembly preload is a major aspect for an adequate performance of the system. During the design phase it is imperative to define reference values to this preload, so the application would endure its requirements. However, with the assistance of computer simulations, it is possible to determine an optimum condition of operation, i.e. optimum pre-load, which would increase the system reliability. This paper presents a study on the influence of preload on the rating life of tapered roller bearings applied to light-weight front axle differentials, evaluating how preload affects several key parameters such as rating life and displacement of components, taking into account the flexibility of the surrounding differential housing. Copyright © 2012 SAE International.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per group): (a) 50μm Al2O3 particles, (b) 110μm Al2O3 particles coated with silica (Rocatec Plus), (c) 30μm Al2O3 particles coated with silica (CoJet Sand) for 20s at 2.8bar pressure. Control group received no air-abrasion. All specimens were initially cyclic loaded (×20,000, 50N, 1Hz) in water at 37°C and then subjected to biaxial flexural strength testing where the conditioned surface was under tension. Zirconia surfaces were characterized and roughness was measured with 3D surface profilometer. Phase transformation from tetragonal to monoclinic was determined by Raman spectroscopy. The relative amount of transformed monoclinic zirconia (FM) and transformed zone depth (TZD) were measured using XRD. The data (MPa) were analyzed using ANOVA, Tukey's tests and Weibull modulus (m) were calculated for each group (95% CI). The biaxial flexural strength (MPa) of CoJet treated group (1266.3±158A) was not significantly different than that of Rocatec Plus group (1179±216.4A,B) but was significantly higher than the other groups (Control: 942.3±74.6C; 50μm Al2O3: 915.2±185.7B,C). Weibull modulus was higher for control (m=13.79) than those of other groups (m=4.95, m=5.64, m=9.13 for group a, b and c, respectively). Surface roughness (Ra) was the highest with 50μm Al2O3 (0.261μm) than those of other groups (0.15-0.195μm). After all air-abrasion protocols, FM increased (15.02%-19.25%) compared to control group (11.12%). TZD also showed increase after air-abrasion protocols (0.83-1.07μm) compared to control group (0.59μm). Air-abrasion protocols increased the roughness and monoclinic phase but in turn abrasion with 30μm Al2O3 particles coated with silica has increased the biaxial flexural strength of the tested zirconia. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The goal of implant treatment is the formation of a direct bone-implant interface contact. Purpose: This study aimed to evaluate the possibilities of immediate loading treatment for edentulous patients rehabilitated with mandibular and maxillary overdentures. Material and methods: A literature review using the PubMed and BIREME databases between the periods of 1977 and 2011 was performed. Results: From an initial yield of 218 titles, 78 articles were selected for text analysis, finally resulting in 23 studies (16 prospective, 6 prospective randomized, and 1 prospective multicenter) that met the inclusion criteria. Conclusion: The immediate loading protocol through which the implants are subjected to occlusal function immediately after their placement was introduced to overcome this limitation. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the problem of applying an impulsive control in a spacecraft that is performing a Swing-By maneuver. The objective is to study the changes in velocity, energy and angular momentum for this maneuver as a function of the three usual parameters of the standard Swing-By plus the three parameters (the magnitude of the impulse, the point of its application and the angle between the impulse and the velocity of the spacecraft) that specify the impulse applied. The dynamics used is the restricted three body problem under the regularization of Lemaitre, made to increase the accuracy of the numerical integration near the primaries. The present research develops an algorithm to calculate the variation of energy and angular momentum in a maneuver where the application of the impulsive control occurs before or after the passage of the spacecraft by the periapsis, but within the sphere of influence of the secondary body and in a non-tangential direction. Using this approach, it is possible to find the best position and direction to apply the impulse to maximize the energy change of the total maneuver. The results showed that the application of the impulse at the periapsis and in the direction of motion of the spacecraft is usually not the optimal solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of different air-particle abrasion protocols on the biaxial flexural strength and structural stability of zirconia ceramics. Zirconia ceramic specimens (ISO 6872) (Lava, 3M ESPE) were obtained (N=336). The specimens (N=118, n=20 per group) were randomly assigned to one of the air-abrasion protocols: Gr1: Control (as-sintered); Gr2: 50 μm Al2O3 (2.5 bar); Gr3: 50 μm Al2O3 (3.5 bar); Gr4: 110 μm Al2O3(2.5 bar); Gr5: 110 μm Al2O3 (3.5 bar); Gr6: 30 μm SiO2 (2.5 bar) (CoJet); Gr7: 30 μm SiO2(3.5 bar); Gr8: 110 μm SiO2 (2.5 bar) (Rocatec Plus); and Gr9: 110 μm SiO2 (3.5 bar) (duration: 20 s, distance: 10 mm). While half of the specimens were tested immediately, the other half was subjected to cyclic loading in water (100,000 cycles; 50 N, 4 Hz, 37 °°C) prior to biaxial flexural strength test (ISO 6872). Phase transformation (t→m), relative amount of transformed monoclinic zirconia (FM), transformed zone depth (TZD) and surface roughness were measured. Particle type (p=0.2746), pressure (p=0.5084) and cyclic loading (p=0.1610) did not influence the flexural strength. Except for the air-abraded group with 110 μm Al2O3 at 3.5 bar, all air-abrasion protocols increased the biaxial flexural strength (MPa) (Controlnon-aged: 1030±153, Controlaged: 1138±138; Experimentalnon-aged: 1307±184-1554±124; Experimentalaged: 1308±118-1451±135) in both non-aged and aged conditions, respectively. Surface roughness (Ra) was the highest with 110 μm Al2O3(0.84 μm. FM values ranged from 0% to 27.21%, higher value for the Rocatec Plus (110 μm SiO2) and 110 μm Al2O3 groups at 3.5 bar pressure. TZD ranged between 0 and 1.43 μm, with the highest values for Rocatec Plus and 110 μm Al2O3 groups at 3.5 bar pressure. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO:A melhor dose para o início do tratamento anticoagulante com varfarina vem sendo debatida nos últimos dez anos. Em nosso meio, não observamos nenhum estudo comparativo quanto a estas características.OBJETIVO:Comparar segurança e eficácia de dois esquemas de dosagem inicial de varfarina para tratamento anticoagulante.MÉTODOS:Foram estudados prospectivamente 110 pacientes de ambos os sexos, consecutivos, com indicação de anticoagulação por tromboembolismo venoso ou arterial. Durante os três primeiros dias de tratamento, estes pacientes receberam doses adequadas de heparina (RT - razão dos tempos - alvo entre 1,5 e 2,5) e 5 mg de varfarina, cuja dose foi reajustada a partir do quarto dia pelo Razão Normatizada Internacional - RNI (alvo entre 2 e 3). Esse grupo foi comparado com série histórica de 110 pacientes que receberam 10 mg nos dois primeiros dias, 5 mg a partir do terceiro dia, com ajuste posterior de dose baseado no RNI. Os desfechos foram: recorrência do tromboembolismo, sangramentos e tempo para alcançar níveis terapêuticos.RESULTADOS:A eficácia, a segurança e o tempo de internação foram similares entre os grupos. O grupo que recebeu 10 mg atingiu níveis terapêuticos mais precocemente (média de 4,5 dias × 5,8 dias), sendo as doses na alta menores e os níveis terapêuticos mais adequados na primeira visita de retorno.CONCLUSÃO:O esquema de dosagem de 10 mg proporcionou menor tempo para alcançar nível terapêutico, com menores doses de varfarina na alta e RNI mais adequado no retorno.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moderate and controlled loading environments support or enhance osteogenesis, and, consequently, a high degree of bone-to-implant contact can be acquired. This is because when osteoprogenitor cells are exposed to limited physical deformation, their differentiation into osteoblasts is enhanced. Then, some range of microstrain is considered advantageous for bone ingrowth and osseointegration. The primary stability has been considered one of the main clinical means of controlling micromotion between the implant and the forming interfacial tissue, which helps to establish the proper mechanical environment for osteogenesis. Based on the biological aspects of immediate loading (IL), the objective of this study is to present a clinical case of maxillary arch rehabilitation using immediate loading with implant-supported fixed restoration after bone graft. Ten dental implants were placed in the maxilla 6 months after the autogenous bone graft, removed from the mandible (bilateral oblique line and chin), followed by the installation of an immediate-load fixed cross-arch implant-supported restoration because primary stability was reached for 8 implants. In addition, instructions about masticatory function and how it is related to interfacial micromotion were addressed and emphasized to the patient. The reasons for the IL were further avoidance of an interim healing phase, a potential reduction in the number of clinical interventions for the patient, and aesthetic reasons. After monitoring the rehabilitation for 8 years, the authors can conclude that maxillary IL can be performed followed by a well-established treatment planning based on computed tomography, providing immediate esthetics and function to the patient even when autogenous bone graft was previously performed in the maxilla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article investigates complex impulsive systems in which the so-called controlling systems jumps effect emerges. In particular, this research includes the correctness of the solution to the impulsive control system and approximation lemmas. A 3D model example is provided which illustrates the relevance of the considered approach to the study of complex impulsive systems.