69 resultados para Performance of the stock funds


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper is presented an experimental research in which the grinding of seating surfaces of inlet engine valves was improved by the adoption of the most effective cutting fluid type, matching the new requirements of cutting fluid application. Four different types of cutting fluids (straight oil and three different types of soluble oils) were analyzed. As qualitative and quantitative evaluation parameters of the performance of the cutting fluids, the roughness, the grinding wheel wear, the cutting force and the workpiece residual stress were determined. As a conclusion, the straight oil was the cutting fluid that presented the best results in all of the parameters analyzed. Copyright © 2000 Society of Automotive Engineers, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electromyographic activity of the trapezius muscle and serratus anterior muscle was analysed in 4 different modalities of military press exercises, each of them with 2 grips: open and middle. It was analyzed 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The TS and SI muscles acted with high and very high activity in all the modalities of military press exercises. Statistically, they did not show significative difference in the performance of the exercises with open and middle grip, justifying the inclusion of this group of exercises with both grips for the physical conditioning programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operational details of the apparent electrical conductivity (ECa) sensor manufactured by Veris Technologies have been extensively documented in literature reports, but the geographical distribution of these research studies indicate a strong regional concentration in the US Mid-west and Southern states. The agricultural lands of these states diverge significantly to the soil conditions and water regime of irrigated land in the US South-western states such as Arizona where there is no previous research reports of the use of this particular sensor. The objectives of the present study were to analyze the performance of this sensor under the conditions of typical soils in irrigated farms of Central Arizona. We tested under static conditions the performance of the sensor on three soils of contrasting texture. Observations were collected as time series data as soil moisture changed from saturation to permanent wilting point. Observations were repeated at the hours of lowest and highest temperatures. In addition, this study included soil penetration resistance and salinity determinations. Preliminary results indicate that soil temperature of the upper layer caused the most dynamic change in the sensor output. The ECa curves of the three soil textures tested had well defined distinctive characteristics. Final multivariate analysis is pending.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The advance in the graphic computer's techniques and computer's capacity of processing made possible applications like the human anatomic structures modeling, in order to investigate diseases, surgical planning or even provide images for training of Computer Aided Diagnosis (CAD). On this context, this work exhibits an anatomical model of cardiac structures represented in a tridimensional environment. The model was represented with geometrical elements and has anatomical details, as the different tunics that compose the cardiac wall and measures that preserves the characteristics found on real structures. The validation of the anatomical model was made through quantitative comparations with real structures measures, available on specialized literature. The results obtained, evaluated by two specialists, are compatible with real anatomies, respecting the anatomical particularities. This degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the cardiac diseases on the quality of the images, as well as on the performance of the CAD. © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of ICDAS training in a group of dental students for occlusal caries detection in permanent teeth. Premolars and molars (N=104) with occlusal surfaces varying from ICDAS scores 0 to 6 were cleaned, one occlusal site per tooth was selected, and a photograph taken to identify the site. Eight senior dental students examined the teeth twice with a one-week interval between examinations during each of two phases: before and after the ICDAS e-learning program. Teeth were histologically assessed for caries extension. Intraclass correlation coefficients for intra- and interexaminer repeatability were high, both before (0.75 and 0.72, respectively) and after e-learning (0.82 and 0.78, respectively). The ICDAS scores decreased significantly from before to after e-learning (p=0.0001). Correlation between ICDAS scores and histology scores was moderate (0.57 before e-learning and 0.61 after). Although the ROC curve shows an improvement in the use of the ICDAS scoring after e-learning, the difference was not significant (p=0.10). Specificity of the ICDAS scores significantly improved after e-learning (77 percent vs. 36 percent), and sensitivity was reduced slightly after e-learning (87 percent vs. 92 percent). The ICDAS e-learning program improved the performance of the diagnostic skills of the investigated students for the detection of occlusal caries lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For intricate automotive systems that enclose several components, such as gearboxes, an important aspect of the design is defining the correct assembly parameters. A proper assembly can ensure optimized operating conditions and therefore the components can achieve a longer life. In the case of the support bearings applied to front-axle lightweight differentials, the assembly preload is a major aspect for an adequate performance of the system. During the design phase it is imperative to define reference values to this preload, so the application would endure its requirements. However, with the assistance of computer simulations, it is possible to determine an optimum condition of operation, i.e. optimum pre-load, which would increase the system reliability. This paper presents a study on the influence of preload on the rating life of tapered roller bearings applied to light-weight front axle differentials, evaluating how preload affects several key parameters such as rating life and displacement of components, taking into account the flexibility of the surrounding differential housing. Copyright © 2012 SAE International.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Among the locked internal fixators is one denominated S.P.S. (Synthesis Pengo System) Free-Block, which was designed with a locking ring that allows the screw to be locked and positioned obliquely. Due to the paucity of biomechanical studies on this system, the present work aimed to evaluate the influence of locked screw angulation on the resistance of the S.P.S. Free--Block plate. Methods: Forty synthetic bone cylinders with 10 mm fracture gap were used. Forty seven-hole 3.5 mm stainless steel plates (two AO-like dynamic compression holes and five locked holes) were assembled according to the orientation of the locked screws: mono cortical screws were positioned at 90° to the long axis of the cylinder (Group 1), and monocortical screws were positioned at 70° to its cylinder long axis (Group 2). In both groups, AO-like dynamic compression hole screws were positioned bicortically and neutrally. For each group, six specimens were tested until failure, three in bending and three in compression, to determine the loads for fatigue testing. Subsequently, for each group, 14 specimens were tested for failure --seven by bending and seven in compression. Results: No significant failure differences were observed between Groups 1 and 2 under static-loading or fatigue test. Clinical significance: In a fracture gap model the orientation of the locked monocortical screws did not show any influence on the mechanical performance of the S.P.S. Free-Block to tests of axial compression and four-point bending. © Schattauer 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared the artisanal fisheries, in terms of catch strategies, productivity, and gross per capita income, at two reservoirs: The Barra Bonita (an eutrophic reservoir with some introduced species), and the Jurumirim (an oligotrophic reservoir, with no introduced species). Published data and structured interviews with fishers were used to evaluate fishing activity, fish biomass, and the financial performance of the fisheries. In the Barra Bonita Reservoir we analysed data from 745 fishing trips, from which 86,691.9 kg of fish were landed, with a mean CPUE of 62.4 kg/fisher-1 day-1. The main type of fish caught was tilapia (71,513.5 kg; CPUE of 51.5 kg/fisher-1 day-1), which constituted 82.5% of the biomass caught. In the Jurumirim Reservoir, we analysed data from 2,401 fishing trips, from which 25,093.6 kg of fish were landed, with a mean CPUE of 10.4 kg/fisher-1 day-1. The main type of fish caught was traíra (6,158.6 kg; CPUE of 2.6 kg/fisher-1 day-1), which constituted 24.5% of the biomass caught. Ordination analysis (PCA) indicated that there was a difference in composition between the fishing reservoirs and ANCOVA showed that there was a significant difference in fish production between the reservoirs. A Student's t-test showed that fishers in the Barra Bonita Reservoir had a significantly higher gross per capita income than those from the Jurumirim Reservoir. Although the Barra Bonita Reservoir has a higher fish production and the fishers earn a higher gross per capita income, we recommend the Jurumirim Reservoir as a model for artisanal fishery management because fishing activity in this reservoir is viable in the long term and such a model would promote conservation and sustainability. This contrasts with the Barra Bonita Reservoir, in which the fishery is not viable in the long term, due to environmental problems caused by artificial eutrophication and the introduction of alien species. It is also noted that in many countries, management of fisheries based on exotic species has not been viable in the long term. © 2013 Sociedade Brasileira de Ictiologia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The factors that have influence on the energy consumption of a small air conditioning system that are worth mentioning are the efficiencies of the compressor, evaporator and condenser, the form that the refrigerant flow is controlled, the fan model used, and climatic conditions. Within the climate issue, an interesting factor is that the relative humidity when it comes to the effect that it causes, especially in the performance of the air condenser, which generally is not considered in the projects. This study aims to evaluate the influence of humidity on the coefficient of system performance (COP), seeking to quantify their influence when it happens. The tests were performed on a testing bench, mounted at the Laboratory for Energy Efficiency (LAMOTRIZ) UNESP-Campus Guaratinguetá. In the study, the wet bulb temperature was ranged, keeping the rotation of the scroll compressor with application of a frequency inverter in its best performance. The test bench is provided with a supervisory system of data collection that is also able to control all functions of the bench. In the results, there was a significant influence, particularly when comparing high humidity conditions with low humidity, noting that only over 65% relative humidity is that significant changes are observed in the COP of the system. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Constant Flux: Constant Sedimentation (CF:CS) and Constant Rate of Supply (CRS) of unsupported/excess Pb-210 models have been applied to a Pb-210 data set providing of eighteen sediments profiles sampled at four riverine systems occurring in Brazil, South America: Corumbatai River basin (S1=Site 1, Sao Paulo State), Atibaia River basin (S2=Site 2, Sao Paulo State), Ribeirao dos Bagres basin (S3=Site 3, Sao Paulo State) and Amazon River mouth. (S4=Site 4, Amapa State). These sites were chosen for a comparative evaluation of the performance of the CF:CS and CRS models due to their pronounced differences on the geographical location, geological context, soil composition, biodiversity, climate, rainfall, and water flow regime, among other variable aspects. However, all sediments cores exhibited a common denominator consisting on a database built from the use of the same techniques for acquiring the sediments major chemical composition (SiO2, Al2O3, Na2O, K2O, CaO, MgO, Fe2O3, MnO, P2O5, TiO2 and LOI-Loss on Ignition) and unsupported/excess 210Pb activity data. In terms of sedimentation rates, the performance of the CRS model was better than that of the CF:CS model as it yielded values more compatible with those expected from field evidences. Under the chronological point of view, the CRS model always provided ages within the permitted range of the Pb-210-method in the studied sites, whereas the CF:CS model predicted some values above 150 years. The SiO2 content decreased in accordance with the LOI increase in all cores analyzed and such inverse relationship was also tracked in the SiO2-LOI curves of historical trends. The SiO2-LOI concentration fluctuations in sites S1 and S3 also coincided with some Cu and Cr inputs in the drainage systems. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of bovine rumen fluid inoculum during anaerobic treatment of the organic fraction of municipal solid waste (MSW) was studied in this work. The parameters adopted for evaluation were the biostabilization constant of total volatile solids (TVs) and the biostabilization time of the chemical oxygen demand (COD) applied to the reactors. The work was realized in four anaerobic batch reactors of 20 1 capacity each, during a period of 365 days. The proportions between MSW/inoculum loaded in the reactors were Reactor A (100%/0%), Reactor B (95%/5%), Reactor C (90%/10%) and Reactor D (85%/15%). The necessary time for biostabilization of half of the applied COD was 459, 347, 302 and 234 days and the average of methane concentration in the biogas produced was 3.6%, 13.0%, 25.0% and 42.6% for Reactors A, B, C and D, respectively. The data obtained affirm that the inoculum used substantially improved the performance of the process. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)