69 resultados para Paraphrasing and plagiarism detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are few reports concerning the epidemiology of Eimeria praecox and Eimeria mitis in Brazil. In the present experiment, the polymerase chain reaction (PCR) was used to identify these species in 156 samples of broiler chicken feces from several Brazilian states and the Federal District. Oocysts present in feces samples were purified by sodium chloride flotation followed by addition of DNAzol reagent (Invitrogen®) for extraction of genomic DNA. DNA was precipitated and stored following DNAzol reagent manufacture's instructions. The primers and PCR conditions were as described by Schnitzler et al. (1999). In the 156 field samples analyzed by PCR, 70 and 45 were positive for E. praecox and E. mitis, respectively. In this study we have shown that DNA extraction using DNAzol followed by PCR can be a useful tool in epidemiological studies, since it provides fast and reliable detection of Eimeria sp. in field samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characteristics, performance, and application of a novel and simple electrode, namely Pt vertical bar Hg vertical bar Hg-2(MF)(2)vertical bar Graphite, where MF stands for mefenamate ion, are described. This electrode responds to MF with sensitivity of (58.9 +/- 0.7) mV decade(-1) over the range 1.0 x 10(-6) to 1.0 x 10(-2) mol L-1 at pH 6.0-9.0 and a detection limit of 6.2 x 10(-7) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-25 s) and can be used for a period of 4 months without significant change in its performance characteristics. The proposed sensor displayed good selectivity for mefenamate in the presence of several substances, especially concerning carboxylate and inorganic anions. The potentiometric sensor was successfully applied to the determination of mefenamic acid in pharmaceuticals and human serum samples. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and attractive method for quantification of ascorbic acid (AA) in beers, soda, natural juices and commercial vitamin C tablets was achieved by combining Bow injection analysis and amperometric detection. An array of gold microelectrodes electrochemically modified by deposition of palladium was employed as working electrode which was almost unaffected by fouling effects. Ascorbic acid was quantified in beverages and vitamin tablets using amperometric differential measurements. This method is based on three steps involving the flow injection of: 1) the sample plus a standard addition of AA, 2) the pure sample, and 3) the enzymatically-treated sample. The enzymatic treatment was carried out with Cucumis sativus tissue, which is a rich source of ascorbate oxidase, at pH 7. The calibration plots for freshly prepared ascorbic acid standards were very linear in the concentration range of 0.18-1.8 mg L-1 with a relative standard deviation (RSD) < 1%, while for real samples the deviations were between 2.7% to 8.9%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The bacterial wilt caused by Curtobacterium flaccumfaciens pv. flaccumfaciens is currently considered one of the most important bacterial bean disease in Brazil. One of the most effective control methods against this disease is the use of healthy seeds. However, no methods are known that could be routinely used to detect this bacterium in bean seeds under Brazilian condition. The aim of this work was to evaluate qualitative and quantitative detection methods for Curtobacterium flaccumfaciens pv. flaccumfaciens in naturally-infected bean seeds, and the detection of this pathogen in thirty bean seed samples, by sowing onto a semi- selective culture medium the leachate obtained from soaked bean seeds. Both the qualitative and quantitative methods were effective for detecting the presence of the bacteria in the seeds samples analysed. The qualitative method proved more practical for rotine use; of the thirty bean seed samples analyzed by this method, fifty percent were infected with Curtobacterium flaccumfaciens pv. flaccumfaciens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cyclic voltammetric behavior of acetaldehyde and the derivatized product with 2,4-dinitrophenylhydrazine (DNPHi) has been studied at a glassy carbon electrode. This study was used to optimize the best experimental conditions for its determination by high-performance liquid chromatographic (HPLC) separation coupled with electrochemical detection. The acetaldehyde-2,4-dinitrophenyl.hydrazone (ADNPH) was eluted and separated by a reversed-phase column, C-18, under isocratic conditions with the mobile phase containing a binary mixture of methanol/LiCl(aq) at a concentration of 1.0 x 10(-3) M (80:20 v/v) and a flow rate of 1.0 mL min(-1). The optimum condition for the electrochemical detection of ADNPH was +1.0 V vs. Ag/AgCl as a reference electrode. The proposed method was simple, rapid (analysis time 7 min) and sensitive (detection limit 3.80 mu g L-1) at a signal-to-noise ratio of 3:1. It was also highly selective and reproducible [standard deviation 8.2% +/- 0.36 (n = 5)]. The analytical curve of ADNPH was linear over the range of 3-300 mg L-1 per injection (20 mu L), and the analytical recovery was > 99%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure to determine residue concentrations of synthetic pyrethroid insecticides (flumethrin, deltamethrin, cypermethrin and cyhalothrin) in the milk and blood of lactating dairy cows was developed. Extraction was performed with acetonitrile, n-hexane partitioning, and silica gel column cleanup with n-hexane and diethyl ether. Analysis was carried out by high- performance liquid chromatography and ultraviolet detection. Recovery of the four pyrethroids averaged 78 to 91% with a minimum detectable concentration of 0.001 mg/kg. The method was reproducible and sensitive.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new biflavonol, named chimarrhoside (1), and eight known flavonol glycosides (2-9), were isolated from the leaves of Chimarrhis turbinata. Their structures were established on the basis of 1D and 2D NMR experiments as quercetin-3-O-rutinoside (2), kaempferol-3-O-rutinoside (3), kaempferol-3-O-α-L-rhamnopyranosyl-(1→6)-β-D-galactopyranoside (4), quercetin-3-O-α-L-rhamnopyranosyl-(1→6)-β-D- galactopyranoside (5), 6-hydroxy-rutin (6), kaempferol-3-O-D-galactopyranoside (7), kaempferol-3-O-D-glucopyranoside (8) and kaempferol-3-O-α- Lrhamnopyranosyl-(1→6)-α-L-rhamnopyranosyl-(1→4) -β-D-glucopyranoside (9). In addition, catechin (10) and catechin-(4α→8)-catechin-procyanidin B-3) (11) were isolated. The crude extract, fractions and isolated compounds were evaluated for their antioxidative properties using an autographic assay based on β-carotene bleaching on TLC plates, and spectrophotometric detection by reduction of the stable 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical. Flavonoids 2, 5, 6, 10 and 11 displayed strong free radical scavenging activity, when compared with the standards BHT and rutin. ©2005 Sociedade Brasileira de Química.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow-cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III). The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2-210 μmol l-1 H2O2 with a LD of 1.8 μmol l-1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10-5 mol l-1 and 6.8×10-5 mol l-1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 μg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved. Copyright © Taylor & Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DNA biosensors have gained increased attention over traditional diagnostic methods due to their fast and responsive operation and cost-effective design. The specificity of DNA biosensors relies on single-stranded oligonucleotide probes immobilized to a transduction platform. Here, we report the development of biosensors to detect the hippuricase gene (hipO) from Campylobacter jejuni using direct covalent coupling of thiol- and biotin-labeled single-stranded DNA (ssDNA) on both surface plasmon resonance (SPR) and diffraction optics technology (DOT, dotLab) transduction platforms. This is the first known report of the dotLab to detect targeted DNA. Application of 6-mercapto-1-hexanol as a spacer thiol for SPR gold surface created a self-assembled monolayer that removed unbound ssDNA and minimized non-specific detection. The detection limit of SPR sensors was shown to be 2.5 nM DNA while dotLab sensors demonstrated a slightly decreased detection limit of 5.0 nM (0.005 μM). It was possible to reuse the SPR sensor due to the negligible changes in sensor sensitivity (∼9.7 × 10 -7 ΔRU) and minimal damage to immobilized probes following use, whereas dotLab sensors could not be reused. Results indicated feasibility of optical biosensors for rapid and sensitive detection of the hipO gene of Campylobacter jejuni using specific ssDNA as a probe. © 2011 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The preparation and electrochemical characterization of hausmannite-type manganese oxide to use as a sensing material for sodium ion is described. This paper reports a new via synthetic to obtain of the hausmannite-type manganese oxide and its application in the construction of modified electrode as a voltammetric sensor. The electrochemical activity of hausmannite-type manganese oxide is controlled by intercalation/deintercalation of the sodium ions within the oxide lattice. The detection is based on the measurement of anodic current generated by oxidation of MnIII-MnIV at electrode surface. The best electrochemical response was obtained for a sensor composition of 20% (w/w) hausmannite oxide in the paste, a TRIS buffer solution of pH 6.0-7.0 and a scan rate of 50 mV s-1. A sensitive linear voltammetric response for sodium ions was obtained in the concentration range of 2.01 × 10 -5-2.09 × 10-4 mol L-1 with a slope of 355 μA L mmol-1 and a detection limit of 7.50 × 10 -6 mol L-1 using cyclic voltammetry. The use of hausmannite has significantly improved the selectivity of the sensor compared to the birnessite-type manganese oxide modified electrode. Under the working conditions, the proposed method was successfully applied to determination of sodium ions in urine samples. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective was to evaluate serum activity of the enzymes creatine kinase (CK) and aspartate aminotransferase (AST), which are leakage enzymes responsive to muscle injury, of athletic horses that underwent muscle biopsy and incremental jump test (IJT) involving incremental jumps. The animals were grouped as follows: the first group, horses with history of superior performance (SP); the second, with a history of inferior performance (IP); and lastly, a control group (CG). All groups underwent biopsy of the gluteus medius muscle, while groups SP and IP were also submitted to the incremental jump test (IJT) 24 hours after biopsy. The IJT consisted of three stages with 40 jumps each, where jump height increased progressively, from 40 to 60 and last, 80cm. Blood samples were drawn before biopsy, and 6 and 24 hours after the exercise as well. The levels of CK serum activity increased 6 hours after exercise and decreased 24 hours later in all groups, including CG. AST activity did not increase after biopsy and exercise. There was no increase of both enzyme activities that could be attributed to the exercise, possibly due to exercise short duration and/or low intensity. We conclude that the muscle biopsy was able to show that there was enough stimulus to cause CK enzyme leakage into the plasma, and consequent detection of increased serum activity, while the incremental jump test did not.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)