307 resultados para Orbital Implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: It is unknown whether different micro gap configurations can cause different pen-implant bone reactions. Therefore, this study sought to compare the peri-implant bone morphologies of two implant systems with different implant-abutment connections. Materials and Methods: Three months after mandibular tooth extractions in six mongrel dogs, two oxidized screw implants with an external-hex connection were inserted (hexed group) on one side, whereas on the contralateral side two grit-blasted screw implants with an internal Morse-taper connection (Morse group) were placed. on each side, one implant was inserted level with the bone (equicrestal) and the second implant was inserted 1.5 mm below the bony crest (subcrestal). Healing abutments were inserted immediately after implant placement. Three months later, the peri-implant bone levels, the first bone-to-implant contact points, and the width and steepness of the peri-implant bone defects were evaluated histometrically. Results: All 24 implants osseointegrated clinically and histologically. No statistically significant differences between the hexed group and Morse group were detected for either the vertical position for peri-implant bone levels (Morse equicrestal -0.16 mm, hexed equicrestal -0.22 mm, Morse subcrestal 1.50 mm, hexed subcrestal 0.94 mm) or for the first bone-to-implant contact points (Morse equicrestal -2.08 mm, hexed equicrestal -0.98 mm, Morse subcrestal -1.26 mm, hexed subcrestal -0.76 mm). For the parameters width (Morse equicrestal -0.15 mm, hexed equicrestal -0.59 mm, Morse subcrestal 0.28 mm, hexed subcrestal -0.70 mm) and steepness (Morse equicrestal 25.27 degree, hexed equicrestal 57.21 degree, Morse subcrestal 15.35 degree, hexed subcrestal 37.97 degree) of the pen-implant defect, highly significant differences were noted between the Morse group and the hexed group. Conclusion: Within the limits of this experiment, it can be concluded that different microgap configurations influence the size and shape of the peri-implant bone defect in nonsubmerged implants placed both at the crest and subcrestally. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:540-547

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment.Objective: The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants.Materials and methods: The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system.Conclusion: The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of the present study was to evaluate the influence of radiation in osseointegrated dental implants installed in tibiae of rats.Material and methods: Screw-shaped implants (2.5 mm diameter by 3.5 mm length) were custom made from commercially pure titanium bars. Titanium implants were blasted and sterilized before implantation. Animals were divided into two groups of 12 animals each and the rats were not paired after the groups' formation. The experimental group (group 1) received external irradiation 4 weeks after surgery while in the control group (group 2) animals were kept free of radiation. The shear strength required to detach the implant from bone was measured by push-out testing and osseointegration was histologically evaluated.Results: Results showed that the compressive strength of irradiated implants (33.49 MPa) was significantly lower than the compressive strength of non-irradiated implants (48.05 MPa).Conclusions: We concluded that the mechanical strength bonding between implants and host tissues decreased after irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Transitional implants are indicated for cases in which immediate loading is counter-indicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. Method and Materials: The present literature review was based on the OldMedline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. Results: The transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. Conclusion: Transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading. (Quintessence Int 2011; 42: 19-24)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the process of facial rehabilitation, the mobility of ocular prostheses must be considered. Whereas some factors depend exclusively on the dentist, such as molding techniques and selection of material for denture construction, regarding ocular rehabilitation, factors, such as type of surgery, whether to adopt implants, and the use of lubricants, deserve special attention owing to their integration and their association with other factors pertaining exclusively to the patient. To establish harmony, and with the intention of aiding the dentist, after a discerning evaluation, the authors of this study report the factors that provide greater or less mobility to ocular prostheses and conceal the prosthesis in a more natural way, thereby contributing toward achieving a favorable aesthetic result in rehabilitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives:This study evaluated the influence of ovariectomy 8 weeks after implant placement on bone integrated to titanium implants.Materials and methods:Thirty-eight female rats were submitted to a titanium implant at the tibiae proximal methaphysis. After a healing period of 8 weeks the animals were randomly divided into three groups: control (CTL-10 animals), sham-operated (SHAM-14 animals) and ovariectomy (OVX-14 animals). The CTL group was then sacrificed in order to confirm integration of the implant. The SHAM group was submitted to fictitious surgery and the OVX group was submitted to bilateral ovariectomy. After 12 weeks post-implant placement, the SHAM and OVX groups were sacrificed. In order to confirm the systemic osteopenia in rats, a dual-energy X-ray absorptiometry (DXA) was performed. For the evaluation of bone density, digital radiographs were taken. The grey level of the bone adjacent to implant was measured using image software and the bone density was calculated at six points on both sides of the implant.Results:Densitometry measurements of the femur confirmed systemic bone mass loss in the OVX group. Individualized bone analyses of different regions surrounding the implant showed a significantly lower radiographic bone density (P < 0.05) in the cancellous region of the OVX group (77.48 +/- 23.39 grey levels) when compared with the CTL and SHAM groups (91.61 +/- 32.10 and 102.57 +/- 32.50 grey levels, respectively).Conclusions:The present study showed a decrease of the radiographic bone density in the cancellous region of bone around titanium implants placed 8 weeks before ovariectomy in rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: the failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure.Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 +/- 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant.Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium.Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the influence of cyclosporin A (CsA) administration on bone around integrated dental implants assessed by a bone quality index and by quantitative subtraction radiography.A total of 36 machine surface commercial implants were placed in 18 adult rabbits. After a 3-month healing period without any disturbance, the animals were randomly divided into three groups of six animals each. Group A was sacrificed at this time. CsA was injected subcutaneously in an immunosuppressive dose of 10 mg/kg/day in a test group (Group T), and a Group B served as a control, receiving only vehicle. After 3 months of cyclosporin administration, the animals of both Groups B and T were sacrificed. Radiographs were obtained at implant surgery and at the day of sacrifice with a CMOS sensor. Bone quality around the implants was compared between the groups using a bone quality index and quantitative subtraction radiography.The bone analysis showed that in Group T, the bone quality changed dramatically from a dense cortical to a loose trabecular bone structure (P < 0.0001, chi(2) test) while in Groups A and B there were no significant differences. Quantitative digital subtraction radiography showed significantly (P < 0.05) lower gray shade values (radiographic density) in a region of bone formation around the implants in Group T (118 +/- 12) than in Groups A (161 +/- 6) and B (186 +/- 10).Within the limits of this study, CsA administration has a negative effect on the quality of bone around integrated dental implant.