244 resultados para Method Evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Alcohol use by men and women is very much influenced by social habits and customs. Cultural peculiarities and biological differences between the sexes require more focused and standardized studies. The objective was to systematize information on patterns of alcohol use between the sexes.Method: A literary review (1972-2004) identified 96 publications (Lilacs, Scielo, Medline) and some related books.Results and conclusions: Men drank more and presented more problems (legal, family, social, clinical, traumas and mortality) associated with alcohol use; the consequences of alcohol use in developing countries with low death rates is even higher. Women can face more discrimination by using alcohol as well as worse health problems when they abuse drinking (liver, pancreas, and central and peripheral nervous system problems, psychiatric comorbidity, etc.); sexual abuse is more commonly associated with women than discussing the different responses to treatment. As for social roles/responsibilities exercised by women, there are indications that marriage, employment, and children have a good influence, discouraging alcohol use, while divorce, unemployment, and no children contribute to higher consumption. For both sexes, religion was a protective factor for alcohol use; acculturation was a strong influence in the pattern of alcohol use, and alcohol worsened the evolution of existing psychiatric disorders. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PUSPOSE: To evaluate food intake of patients with urinary lithiasis and idiopathic hypercalciuria (IH). MATERIALS and METHODS: Between August 2007 and June 2008, 105 patients with lithiasis were distributed into 2 groups: Group 1 (n = 55) - patients with IH (urinary calcium excretion > 250 mg in women and 300 mg in men with normal serum calcium); Group 2 (n = 50) - normocalciuria (NC) patients . Inclusion criteria were: age over 18, normal renal function (creatinine clearance = 60 mL/min), absent proteinuria and negative urinary culture. Pregnant women, patients with some intestinal pathology, chronic diarrhea or using corticoids were excluded. The protocol of metabolic investigation was based on non-consecutive collection of two 24-hour samples for dosages of: calcium, sodium, uric acid, citrate, oxalate, magnesium and urinary volume. Food intake was evaluated through the quantitative method of Dietary Register of three days. RESULTS: Urinary excretion of calcium (433.33 ± 141.92 vs. 188.93 ± 53.09), sodium (280.08 ± 100.94 vs. 200.44.93 ± 65.81), uric acid (880.63 ± 281.50 vs. 646.74 ± 182.76) and magnesium (88.78 ± 37.53 vs. 64.34 ± 31.84) was significantly higher in the IH group in comparison to the NC group (p < 0.05). As regards the nutritional composition of food intake of IH and NC groups, there was no statistical significant difference in any nutrient evaluated. CONCLUSION: In our study, no difference was observed in the food intake of patients with urinary lithiasis and IH or NC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os objetivos do presente estudo foram avaliar a correlação entre a contagem eletrônica de células somáticas (eCCS) com o Somaticell® sob diferentes níveis de contagem de células somáticas (CCS) do leite e patógenos causadores de mastites, além de calcular a sensibilidade, especificidade e valores preditivos do Somaticell® utilizando diferentes limites de CCS estabelecidos pelos diferentes países. Trezentos e quarenta amostras de leite foram coletadas assepticamente após realização do California Mastitis Test (CMT). O Somaticell® e a eCCS foram realizados em todas as amostras de leite. A correlação entre o Somaticell® e a contagem eletrônica foi determinada de acordo com o CMT, patógeno isolado e escore de eCCS. de acordo com os escores de CCS estabelecidos, 26,5% das amostras de leite apresentaram escore 1 (69-166 x10³células mL-1), 26,8% escore 2 (167-418x10³células mL-1), 27,4% escore 3 (419-760x10³células mL-1) e 19,4% escore 4 (761 to 1970x10³células mL-1). A eCCS e o Somaticell® apresentaram correlação positiva em quase todos os escores estudados (exceto escore 2 e 3). O valor de r obtido entre CCS e o Somaticell® foi de 0,32. Observou-se que, quando o limite de CCS estabelecido aumentou, a sensibilidade decresceu e os valores de especificidade aumentaram. Os valores preditivos apresentaram-se constantes em todos os limites. Quando o limite de CCS era baixo (<760,000 células mL-1), Somaticell® forneceu resultados consistentemente mais elevados que os valores de CCS. Já para amostras com CCS elevada, Somaticell® resultou em menores contagens que a eCCS. A correlação entre os dois métodos permaneceu relativamente constante em todas as condições e os valores de sensibilidade e especificidade do teste são altamente dependentes do limite estabelecido. Os resultados deste trabalho sugerem que o Somaticell® não é útil para avaliar a CCS do leite, pois seus resultados são significativamente diferentes da eCCS, no entanto, pode ser utilizado como método de triagem, tal como o CMT, para a detecção do aumento da CCS do leite.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dogs are the main domestic reservoirs of L. (L.) chagasi. Once in the vertebrate host, the parasite can cause visceral leishmaniasis, which can also be transmitted to humans. Cytokines are key elements of the host immune response against Leishmania spp. To investigate whether tumor necrosis factor (TNF)-alpha, interleukin (IL)-4 and IL-10 are associated with pattern infection in dogs, these cytokines were quantified in the spleen and liver of dogs naturally infected with L. (L.) chagasi, with or without clinical manifestations, and their levels were correlated with the parasite load verified in these organs. A total of 40 adult dogs naturally infected with L. (L.) chagasi were assessed, together with 12 uninfected control dogs. Samples from spleen and liver were used to determine the cytokine levels by capture ELISA and for quantifying parasite load by real-time PCR. Statistical analysis was performed using the minimum Chi square method and group means were compared using the Tukey test. TNF-alpha, IL-4 and IL-10 levels in infected dogs were higher than in control groups; the liver was the main cytokine-producing organ during infection. The level of splenic TNF-alpha showed correlation with parasite load and may represent an important marker for infection process evolution, with the participation of IL-10. These results may contribute to a clearer understanding of the immune response in dogs infected with L. (L.) chagasi, which may lead to the development of prophylactic or preventive measures for these animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical management of orthodontic patients with dental trauma before or during the treatment is mainly founded on clinical experience, expert opinions, and individual case reports. It is proposed in the literature that teeth sustaining mild trauma with minor damage to the periodontium (e.g. subluxation) should be followed for a period of time before being subjected to orthodontic forces. A minimum period of 3 months has been proposed. In this study, we used an animal model to investigate whether shorter observation periods could be established in case of mild trauma. The periradicular region of rat molars was examined microscopically to determine the biological events of tooth movement started 15 and 30 days after intentional subluxation using an experimental method to induce dentoalveolar trauma. Thirty adult male Wistar rats were assigned to 6 groups (n = 5): Group 1 (control no trauma/orthodontic movement); Group 2: the animals received an orthodontic device and were sacrificed after 7 days; Groups 3 and 4: dentoalveolar trauma (subluxation) was experimentally induced by the application of an axial force of 900 cN on the occlusal surface of the maxillary right first molar, and the animals were sacrificed after 22 and 37 days, respectively; and Groups 5 and 6: 15 and 30 days, respectively, after force application, an orthodontic device was installed and the rats were sacrificed 7 days later. In G5 and G6, the periodontal ligament and pulp tissue were rich in cellular elements and blood vessels, the alveolar bone was preserved, and the root surface presented only very small areas of surface resorption (cementum), maintaining the characteristics of normality. In conclusion, the microscopic alterations in the gingival and periodontal tissues in response to an experimentally induced mild dentoalveolar trauma simulating subluxation were not sufficient to contraindicate starting the orthodontic movement 15 and 30 days after trauma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the histological alterations occurred in the periradicular region of rat molars after intentional subluxation using an experimental method to induce dentoalveolar trauma. Eighteen adult male Wistar rats (Rattus norvegicus albinus) were selected for the study. The dentoalveolar trauma was experimentally induced by the application of an occlusogingival force on the occlusal surface of the maxillary right first molar using a tensiometer secured on a fully articulated support with adjustable steel shafts. The animals were assigned to six groups (n = 3), according to the intensity of the force applied to induce trauma: Group I (GI, control) - no force application; Groups II-VI (GII-GVI) - the animals were subjected to 600, 700, 800, 900 and 1000 cN force, respectively. After experimental induction of trauma, the animals were sacrificed by anesthetic overdose and the right maxillas were removed and processed for histological analysis under light microscopy. In the animals of GII, GIII and GIV, the histological alterations were similar to those described for GI. GVI (1000 cN) presented the most severe alterations, with the occurrence of buccal bone plate fracture, alveolar fracture and root fracture, which are not present in mild traumatic injuries like subluxation. The 900 cN force (GV) was capable to produce clinical and histological alterations in the gingival and periodontal tissues compatible with those observed in subluxation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to compare two methodologies used in the evaluation of tissue response to root-end filling materials in rats. Material and Methods: Forty rats were divided into 4 groups: in Groups I and II (control groups), empty polyethylene tubes were implanted in the extraction site and in the subcutaneous tissue, respectively; in Groups III and IV, polyethylene tubes filled with ProRoot MTA were implanted in the extraction site and in the subcutaneous tissue, respectively. The animals were killed 7 and 30 days after tube implantation, and the hemi-maxillas and the capsular subcutaneous tissue, both with the tubes, were removed. Specimens were processed and evaluated histomorphologicaly under light microscopy. The scores obtained were analyzed statistically by the Kruskal-Wallis test (p<0.05). Results: There were no statistically significant differences between the implantation methods (p=0.78033, p=0.72039). It was observed that the 30-day groups presented a more mature healing process due to smaller number of inflammatory cells. Conclusions: The present study showed no differences in tissue responses as far as the implantation site and the studied period were concerned. Alveolar socket implantation methodology represents an interesting method in the study of the biological properties of root-end filling endodontic materials due to the opportunity to evaluate bone tissue response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.