61 resultados para Key performance indicators
Resumo:
Introduction: The objective of this study was to analyze the spatial behavior of the occurrence of trachoma cases detected in the City of Bauru, State of São Paulo, Brazil, in 2006 in order to use the information collected to set priority areas for optimization of health resources. Methods: the trachoma cases identified in 2006 were georeferenced. The data evaluated were: schools where the trachoma cases studied, data from the 2000 Census, census tract, type of housing, water supply conditions, distribution of income and levels of education of household heads. In the Google Earth® software and TerraView® were made descriptive spatial analysis and estimates of the Kernel. Each area was studied by interpolation of the density surfaces exposing events to facilitate to recognize the clusters. Results: of the 66 cases detected, only one (1.5%) was not a resident of the city's outskirts. A positive association was detected of trachoma cases and the percentage of heads of household with income below three minimum wages and schooling under eight years of education. Conclusions: The recognition of the spatial distribution of trachoma cases coincided with the areas of greatest social inequality in Bauru City. The micro-areas identified are those that should be prioritized in the rationalization of health resources. There is the possibility of using the trachoma cases detected as an indicator of performance of micro priority health programs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A dispersão da amostra de solo é uma etapa fundamental da análise granulométrica, sendo realizada mediante o uso de dispersantes químicos e agitação mecânica. O objetivo deste trabalho foi avaliar a eficiência de mesa agitadora reciprocante de baixa rotação na dispersão mecânica de amostras de solos de diferentes classes texturais. Foram realizadas análises granulométricas em 61 amostras com quatro repetições, empregando o método da pipeta para determinação da fração argila e tamisagem para determinação das frações areia grossa, areia fina e areia total, sendo o silte determinado por diferença. Na avaliação de desempenho, os resultados obtidos com uso da mesa agitadora reciprocante (MAR) foram comparados com dados disponíveis para as mesmas amostras oriundos de relatórios do Ensaio de Proficiência IAC para Laboratórios de Análises de Solos - Prolab/IAC. Análises de acurácia foram realizadas com base nos valores dos intervalos de confiança definidos para cada fração granulométrica componente de cada amostra ensaiada. Indicadores gráficos também foram utilizados na comparação de dados, por meio de dispersão e ajuste linear. A estatística descritiva indicou preponderância de baixa variabilidade em mais de 90 % dos resultados obtidos para as amostras de texturas arenosa, média e argilosa e em 68 % dos obtidos para as amostras de textura muito argilosa, indicando boa repetibilidade dos resultados obtidos com a MAR. Média variabilidade foi mais frequentemente associada à fração silte, seguida da fração areia fina. Os resultados das análises de sensibilidade indicam acurácia de 100 % nas três frações granulométricas - areia total, silte e argila - para todas as amostras analisadas pertencentes às classes texturais muito argilosa, argilosa e média. Para as nove amostras de textura arenosa, a acurácia média foi de 85,2 %, e os maiores desvios ocorreram em relação à fração silte. Nas aproximações lineares, coeficientes de correlação igual (silte) ou superiores (areia total e argila) a 0,93, bem como diferenças menores do que 0,16 entre os coeficientes angulares das retas e o valor unitário, indicam alta correlação entre os resultados de referência (Prolab/IAC) e os obtidos nos ensaios com a MAR. Conclui-se pelo desempenho satisfatório da mesa agitadora reciprocante de baixa rotação para dispersão mecânica de amostras de solo de diferentes classes texturais para fins de análise granulométrica, permitindo recomendar o uso alternativo do equipamento quando se emprega agitação lenta. As vantagens do uso do equipamento nacional incluem o baixo custo, a possibilidade de análise simultânea de grande número de amostras e o uso de frascos comuns, de vidro ou de plástico, baratos e de fácil reposição.
Resumo:
Foi avaliado o desempenho energético da suinocultura integrada à produção de milho em grão em sistema de plantio direto mecanizado. Nesta concepção de integração proposta, os dejetos suínos são utilizados como fertilizantes na produção de milho. O sistema foi delimitado envolvendo as atividades associadas ao manejo dos suínos e de produção do milho (manejo do solo, cultivo e colheita). O período de análise considerado foi de um ano, o que possibilita a produção de três lotes de suínos e duas safras de milho. Para avaliar o desempenho energético, foram criados três indicadores: eficiência energética, eficiência de uso de fontes não renováveis e o custo de energia não renovável para a produção de proteína. As entradas energéticas são compostas pelos insumos e pela infraestrutura, utilizados na criação dos suínos e na produção de milho, e pela radiação solar incidente no agrossistema. Já as saídas são representadas pelos seus produtos (suínos terminados e o milho). Os resultados obtidos nas simulações apontam que a integração melhora o desempenho energético das granjas suinícolas, aumentando a eficiência energética (186%) e a eficiência não renovável (352%), além de reduzir o custo de energia não renovável para a produção de proteína (‑58%).
Resumo:
OBJETIVE: This study aimed to assess the practices of pharmacists in Hospital Care. Method - we interviewed 20 pharmacists from the Pharmacy Division by applying a structured instrument, in September 2005. This instrument addressed aspects related to the main activities at the Hospital Pharmacy, which were assessed according to indicators organized into five areas: sector management, hospital pharmacotechniques, committee activities, information and pharmacotherapeutic follow-up, as well as teaching and research activities.RESULTS: the Pharmacy Division considered all structural aspects under analysis as essential for the good development and application of its services. We found that some essential services, such as the Medication Information Service and Pharmacotherapeutic Follow-up, were absent. Pharmacist professionals were dissatisfied about human resource and physical structure dimensioning, and they presented as not very active in terms of Pharmaceutical Care.CONCLUSION: Results indicate that care is still centered on the drug, with few clinical activities. We suggest reformulations in service management, particularly in the management of pharmacists.
Resumo:
The present experiment was aimed to study the effects of an isocaloric substitution of fat by carbohydrate calories while maintaining the same CP content - on some endocrine parameters and key metabolites of the lipid (L), protein (CP) and carbohydrate (CHO) metabolism and muscle cell membrane integrity of broiler chickens. Ninety male broiler chicks (Cobb) were obtained at 1-day old and raised in an environmentally controlled room. Food and water was provided ad libitum. At day 7, the chicks were provided with the experimental diets: Control diet (CON: 20% CP; 9.1% L; 39.6% CHO), Low lipid diet (LowL: 22% CP; 3.36% L; 59.7% CHO), and low carbohydrate diet (LowCHO: 22% CP; 8.09% L; 46.7% CHO). T e chickens fed the CON manifested the best growth rate feed conversion compared to both other groups. The CO chickens showed the highest plasma T-3 Concentrations at 14 days of age as compared to both LowL and LowCHO chickens. At 35 days of age however, LowL chickens were characterized by the highest plasma T-3 levels. Overall, CON birds had the highest plasma T-4 levels (P < 0.0001) compared to LowL and LowCHO chickens. Plasma corticosterone levels were not affected by diet composition. Glucose levels increased towards the end of the experimental period, but there was no overall effect of diet composition on plasma glucose levels. Chickens fed the CON diet were consistently characterized by the highest plasma uric acid levels compared to LowL and LowCHO chickens. Irrespectively of diet, plasma triglyceride levels were high at 14 days of age, then decreased and finally increased again during the last week. This latter increase was most pronounced for the CON chickens and is congruous with their high fat deposition. At 28 days of age, a significant effect of diet was observed, as CON birds had lower plasma free fatty acid (FFA) levels compared to LowL but not to LowCHO chickens. However there was no overall effect of diet composition on plasma FFA levels. Creatine kinase (CK) activities increased significantly with age and were consistently higher in CON chickens. In conclusion, fast growth in broiler chickens is positively correlated with catabolism of protein from dietary or endogenous origin and (muscle) cell membrane disruption as reflected in high plasma uric acid levels and CK activity, respectively. The currently investigated substitution of fat by CHO had no marked effects on endocrine functioning and intermediary metabolism, but this does not exclude that larger substitutions between both nutrients can have an effect.
Resumo:
Nobiletin (NOB) and tangeretin (TAN), two of the main polymethoxylated flavones (PMFs) in citrus, influence a number of key biological pathways in mammalian cells. Although the impacts of NOB and TAN on glucose homeostasis and cholesterol regulation have been investigated in human clinical trials, much information is still lacking about the metabolism and oral bioavailability of these compounds in animals. In this study, NOB and TAN were administered to rats by gavage and intraperitoneal (ip) injection, and the blood serum concentrations of these compounds and their main metabolites were monitored by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS). In addition to the administered compounds, two metabolites of TAN and eight metabolites of NOB were detected and measured over 24 h. With identical oral doses, nearly 10-fold higher absorption of NOB occurred compared to TAN. For both compounds, maximum levels of glucuronidated metabolites occurred in the blood serum at later time points (similar to 5-8 h) compared to the earlier T(max) a values for NOB and TAN. In most cases the glucuronides occurred at substantially higher concentrations than the aglycone metabolites. Low levels of NOB and TAN and their metabolites were detectable in rat blood serum even at 24 h after treatment.
Resumo:
This article aims to present proposals for improvement of key standards and resolutions concerned about the methodology for calculating the indicator of total harmonic voltage distortion, and should contribute to the process of examining the compatibility of potentially disturbing loads in electric power quality in distribution systems. These proposals were drawn from the analysis of results from measurement campaigns conducted in a case study including analysis of the connection of a new induction furnace in a foundry served by a distributor of São Paulo state. A general historical situating the quality of electric energy in the electricity sector is presented, and methodological guidelines and procedures used in experimental trials are shown. The analysis and discussion of results are prepared to answer the main questions that arise during the implementation of standards, resolutions and procedures. © 2011 IEEE.
Resumo:
In trickle irrigation systems, the design is based on the pre-established emission uniformity (EU) which is the combined result of the equipment characteristics and its hydraulic configuration. However, this desired value of the EU may not be confirmed by the final project (in field conditions) and neither by the yield uniformity. The hypotheses of this research were: a) the EU of a trickle irrigation system at field conditions is equal to the emission uniformity pre-established in the its design; b) EU has always the lowest value when compared with other indicators of uniformity; c) the discharge variation coefficient (VC) is not equal to production variation coefficient in the operational unit; d) the difference between the discharge variation coefficient and the productivity variation coefficient depends on the water depth applied. This study aimed to evaluate the relationship between EU used in the irrigation system design and the final yield uniformity. The uniformity indicators evaluated were: EU, distribution uniformity (UD) and the index proposed by Barragan & Wu (2005). They were compared estimating the performance of a trickle irrigation system applied in a citrus orchard with dimensions of 400m x 600m. The design of the irrigation system was optimized by a Linear Programming model. The tree rows were leveled in the larger direction and the spacing adopted in the orchard was 7m x 4m. The manifold line was always operating on a slope condition. The sensitivity analysis involved different slopes, 0, 3, 6, 9 and 12%, and different values of emission uniformity, 60, 70, 75, 80, 85, 90 and 94%. The citrus yield uniformity was evaluated by the variation coefficient. The emission uniformity (EU) after design differed from the EU pre-established, more sharply in the initial values lower than 90%. Comparing the uniformity indexes, the EU always generated lower values when compared with the UD and with the index proposed by Barragan. The emitter variation coefficient was always lower than the productivity variation coefficient. To obtain uniformity of production, it is necessary to consider the irrigation system uniformity and mainly the water depth to be applied.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Assesment of the TEI index of myocardial performance in dogs with doxorubicin-induced cardiomiopathy
Resumo:
The development of a dose-dependent cardiomyopathy is the main limitation for the use of doxorubicin in chemotherapy protocols in both humans and animals. In this setting, the global myocardial function may be compromised resulting in signs of congestive heart failure. In this study, we investigated the ability of the Tei index of myocardial performance to identify myocardial dysfunction in healthy dogs receiving doxorubicin to a cumulative dose of 210 mg/m(2) over 147 days, comparing it with other standard echocardiographic indicators of systolic and diastolic function. Our results indicated that the Tei index, the isovolumic relaxation time, pre-ejection period and the pre-ejection period-to-left ventricular ejection time ratio were able to identify the cardiotoxic effects of doxorubicin on cardiac function when only 60 mg/m(2) had been administered, while the standard systolic and diastolic parameters, including left ventricular diameter at systole, ejection fraction, and fractional shortening needed at least 120 mg/mg(2) to deteriorate. We concluded that prolonged anthracycline therapy compromises both systolic and diastolic functions, which may be documented earlier by including the Tel index evaluation to the standard echocardiographic assessment of animals receiving doxorubicin.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Obesity has been considered the key in metabolic syndrome (MetS) development, and fat accumulation may be responsible for the occurrence of metabolic abnormalities in hemodialysis patients. The use of gold-standard methods to evaluate obesity is limited, and anthropometric measures may be the simplest methods. However, no study has investigated the association between anthropometric indexes and MetS in these patients. Therefore, the aim was to determine which anthropometric indexes had the best association and prediction for MetS in patients undergoing hemodialysis. Cross-sectional study that included patients older than 18 years, undergoing hemodialysis for at least 3 months. Patients with liver disease and cancer or those receiving corticosteroids or antiretroviral therapy were excluded. Diagnostic criteria from Harmonizing Metabolic Syndrome were used for the diagnosis of MetS. Anthropometric indexes evaluated were body mass index (BMI); percent standard of triceps skinfold thickness and of middle arm muscle circumference; waist circumference (WC); sagittal abdominal diameter; neck circumference; waist-to-hip, waist-to-thigh, and waist-to-height ratios; sagittal index; conicity index; and body fat percentage. Ninety-eight patients were included, 54.1% male, and mean age was 57.8 ± 12.9 years. The prevalence of MetS was 74.5%. Individuals with MetS had increased accumulation of abdominal fat and general obesity. Waist-to-height ratio was the variable independently associated with MetS diagnosis (odds ratio, 1.21; 95% confidence interval, 1.09-1.34; P < .01) and that better predicts MetS, followed by WC and BMI (area under the curve of 0.840, 0.836, and 0.798, respectively, P < .01). Waist-to-height ratio was the best anthropometric predictor of MetS in maintenance hemodialysis patients.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG