184 resultados para Instrumented Indentation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare the pH and calcium ion liberation after use of calcium hydroxide pastes with different paste vehicles in human or bovine teeth. Ninety-two single-rooted human and bovine roots were used. The roots were instrumented and an external cavity preparation was performed. The roots were divided in to human and bovine groups. Each group was subdivided into four subgroups (SB) according to the vehicle:SB1, detergent; SB2, saline; SB3, polyethylenoglycol + camphorated paramonochlorophenol (Calen PMCC) and SB4, polyethylenoglycol + furacyn paramonochlorophenol (FPMC). Specimens were immersed into saline solution at 37 degrees C and after 7 and 14 days pH and calcium ion measurements were made. The results were analyzed by ANOVA and Tukey tests (P < 0.05). There was no statistical difference between bovine and human teeth in the pH analysis (P < 0.05), but bovine teeth provided larger calcium ion liberation than human teeth. Calen PMCC was statistically more effective for pH increase and calcium ion liberation in all analyses, followed by FPMC and saline. Detergent showed the lowest pH alterations and calcium ion liberation. The period of 14 days showed more calcium ionic liberation than the 7-day period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Buprenorphine plasma concentrations were measured after administering buprenorphine (20 mu g/kg) into the lumbosacral epidural space of conscious cats chronically instrumented with an epidural catheter. Blood was collected from a jugular vein before injection and 15, 30, 45 and 60 min and 2, 3, 4, 5, 6, 8, 12 and 24 h after administration. Plasma buprenorphine concentrations were measured using ELISA. Background concentration (before injection) was 1.27 +/- 0.27 ng/mL (mean +/- SD). Including background concentration, the mean peak plasma concentration was obtained 15 min after injection (5.82 +/- 3.75 ng/mL), and ranged from 3.79 to 2.20 ng/mL (30 min-3 h), remaining between 1.93 and 1.77 ng/mL (412 h), and declined to 1.40 +/- 0.62 ng/mL at 24 h. Elimination half-life was 58.8 +/- 40.2 min and clearance 56.7 +/- 21.5 mL/min. Results indicate early rapid systemic uptake of buprenorphine from epidural administration with plasma concentrations similar to using buccal or IM routes by 15 min postinjection. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface).Study design. Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er: YAG laser -1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd: YAG laser -2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunn's test.Results. SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. on the other hand, apicectomies carried out with Er: YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd: YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd: YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas.Conclusions. There were no differences in terms of cut quality between the use of burs and Er: YAG laser or between the 2 surfaces (apical and buccal) treated with Nd: YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e77-e82)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium alloy parts are ideally suited for advanced aerospace systems and surgical implants because of their unique combination of high specific strength at both room temperature and moderately elevated temperature, in addition to excellent corrosion resistance. In this work, results of the Ti-35Nb alloy sintering are presented. This alloy, due to its lower modulus of elasticity and high biocompatibility, is a promising candidate for surgical and aerospace applications. Samples were produced by mixing of initial metallic hydride powders followed by uniaxial and cold isostatic pressing with subsequent densification by isochronal sintering between 700 and 1500 degrees C, in vacuum. Sintering behavior was studied by means of microscopy and density. Sintered samples were characterized for phase composition, microstructure and microbardness by X-ray diffraction, scanning electron microscopy and Vickers indentation, respectively. Samples sintered at high temperatures display a fine plate-like a structure and intergranular P. A few remaining pores are still found, and density above 97% for specimens sintered at 1500 degrees C is reached. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the in vivo antimicrobial activity of 2% chlorhexidine gluconate (FCFRP-USP) used as a root canal irrigating solution in teeth with pulp necrosis and radiographically visible chronic periapical reactions. Culture techniques and measurement of the inhibition zone were used. Twenty-two root canals of incisors and molars of 12 patients were used. After accessing the canal, the first root canal sample was collected with two sterile paper points that were transferred to a tube containing reduced transport fluid. The root canal was instrumented using chlorhexidine solution. A small sterile cotton pellet was placed at the root canal entrance, and the cavity was sealed with zinc oxide-eugenol cement. The canals were maintained empty for 48 h. Three sterile paper points were then introduced to absorb the root canal fluid (second sample). One paper point was placed on an agar plate inoculated with Micrococcus luteus ATCC 9341 and incubated for 24 h at 37°C, and the other two were submitted to microbiological evaluation. Present in 10 cases at baseline, mutans streptococci was reduced by 100% at the second assessment. Treatment showed an efficiency of 77.78% for anaerobic microorganisms at the second assessment. These data suggest that chlorhexidine prevents microbial activity in vivo with residual effects in the root canal system up to 48 h. Copyright © 1999 by The American Association of Endodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was conducted to observe the reaction of apical tissues of dogs' teeth after root canal filling with gutta-percha and mineral trioxide aggregate (MTA) or a glass ionomer (Ketac-Endo) as a sealer. The root canals were instrumented and filled by the lateral condensation technique with the sealers studied. Animals were killed 6 months later, and the specimens were removed and prepared for histological analysis. Results showed no inflammatory reaction of apical tissue and total closure of the apical foramen of all the teeth sealed with MTA. The teeth sealed with Ketac-Endo showed two cases of partial closure and different degrees of chronic inflammatory reaction. In conclusion, MTA exhibited better biological properties than Ketac-Endo. Copyright © 1999 by The American Association of Endodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The transient process of solidification of laminar liquid flow (water) submitted to super-cooling was investigated both theoretically and experimentally. In this study an alternative analytical formulation and numerical approach were adopted resulting in the unsteady model with temperature dependent thermophysical properties in the solid region. The proposed model is based upon the fundamental equations of energy balance in the solid and liquid regions as well as across the solidification front. The basic equations and the associated boundary and initial conditions were made dimensionless by using the Landau transformation to immobilize the moving front and render the problem to a fixed plane type problem. A laminar velocity profile is admitted in the liquid domain and the resulting equations were discretized using the finite difference approach. The numerical predictions obtained were compared with the available results based on other models and concepts such as Neumann analytical model, the apparent thermal capacity model due to Bonacina and the conventional fixed grid energy model due to Goodrich. To obtain further comparisons and more validation of the model and the numerical solution, an experimental rig was constructed and instrumented permitting very well controlled experimental measurements. The numerical predictions were compared with the experimental results and the agreement was found satisfactory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was conducted to observe the healing process of intentional lateral root perforation repaired with mineral trioxide aggregate (MTA). Forty-eight root canals of dogs' teeth were instrumented and filled. After partial removal of the filling, an intentional perforation was made with a bur in the lateral area of the root. The perforations were repaired with MTA or Sealapex (control group). Histological analysis occurred 30 and 180 days after treatment. Results showed no inflammation and deposition of cementum over MTA in the majority of the specimens. In the 180-day period, Sealapex exhibited chronic inflammation in all the specimens and slight deposition of cementum over the material in only three cases. In conclusion, MTA exhibited better results than the control group. Copyright © 2001 by The American Association of Endodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to carry out a scanning electron microscopic (SEM) analysis of the cleaning qualities and smear layer removal from root canal walls, instrumented and irrigated with 2.5% NaOCl, 2.0% chlorhexidine and saline solutions. Fifty extracted teeth were used in this study. All teeth were radiographed to determine the existence of a single canal. The crowns were cut at the cervical limit and the root canals were instrumented with K-type files up to size 45. During root canal preparation, irrigations were made with the different solutions being evaluated: Group 1: 2.5% NaOCl (10 roots); Group 2: 2.5% NaOCl and 17% EDTA for 2 minute (10 roots); Group 3: 2.0% chlorhexidine (10 roots); Group 4: 2.0% chlorhexidine and 17% EDTA for 2 minutes (10 roots); Group 5: saline solution (5 roots); Group 6: saline solution and 17% EDTA for 2 minutes (5 roots). After instrumentation, the canals were irrigated with each one of the solutions and the roots were cut in the buccolingual direction for SEM analysis, at the cervical, middle and apical thirds, to ascertain the presence or absence of smear layer and debris. SEM analysis was performed by three calibrated examiners and scores were submitted to Kruskal-Wallis test at the significance level of p = 5%. Results showed that the use of 17% EDTA decreased the smear layer significantly (p < 0.05) for all evaluated solutions in all thirds. When EDTA was not used, a significantly higher quantity of smear layer on the apical third was observed only in the NaOCl groups. The use of 17% EDTA was significant for debris removal except for the chlorhexidine groups. The following conclusion could be drawn: the use of 17% EDTA was necessary to enhance cleanness of the root canals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The instrumentation applied to the Charpy test machine allows the accompaniment of the specimen answer front the impact load, in form of a sign characteristically dynamic representative of the deformation process and it fractures of material tested. The main advantages of the rehearsal conventional Charpy: low cost, manufacturing sample facilities and simple handle the machine. With the instrumentation, the number of information regarding the process of fracture of the specimen increases. In this work discusses the influence of the hammer geometry in determination of the force during the process of specimen fracture submitted to the instrumented impact test Charpy-V. The purpose is obtaining a hammer, in conformity with Norma ISO 14.556, with great sensibility to register the force during the impact. Two geometries different from hammers were instrumented and rehearsed with material of low tenacity, in this case the steel ABNT 4140 in the condition of having normalized. It could be proven as larger the sensibility of the hammer, adult will be the effects of the shock waves in the strain gages of the transducer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium and its alloys provide high strength-to-weight ratios, good fatigue strength and increased corrosion resistance compared with others materials. Its acceptance in aerospace has been limited by costs considerations such as high cost of raw material, high buy-to-fly ratios and expensive machining operations. Significant cost reductions can be obtained by vacuum sintering and powder metallurgy (P/M) techniques by producing near net shapes and consequently minimizing material waste and machining time. The Ti 35Nb alloy exhibit a low modulus of elasticity. Stemming from the unique combination of high strength, low modulus of elasticity and low density, this alloy is intrinsically more resistant to shock and explosion damages than most other engineering materials. Samples were produced by mixing of initial metallic powders followed by uniaxial and cold isostatic pressing with subsequent densification by sintering between 900 and 1600 °C, in vacuum. Sintering behavior was studied by means of dilatometry. Sintered samples were characterized for phase composition, microstructure and microhardness by X-ray diffraction, scanning electron microscopy and Vickers indentation, respectively. Density was measured by Archimedes method. Copyright © 2004 Society of Automotive Engineers, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the ability of endotoxin to diffuse through dentinal tubules towards the cement and to observe the period of time needed for it to reach the external root surface. Thirty single-rooted human teeth had their crowns and apices removed in order to standardize the root length to 15 mm. Teeth were instrumented until #30 K-file and made externally impermeable with epoxy adhesive, leaving 10 mm of the exposed root (middle third). The specimens were placed in plastic vials and irradiated (60Co gamma-rays). Then, they were divided into 2 groups (n = 15): G1) Escherichia coli endotoxin was inoculated into the root canal of the specimens and 1 ml of pyrogen-free water was put in the tubes; G2) (control): pyrogen-free water was inoculated into the root canals and 1 ml of pyrogen-free water was put in each tube. After 30 min, 2 h, 6 h, 12 h, 24 h, 48 h, 72 h and 7 days, the water of the tubes was removed and replaced. The removed aliquot was tested for the presence of endotoxin. Considering that the endotoxin is a B-lymphocyte polyclonal activator, at each experimental period, B-lymphocyte culture was stimulated with a sample of water removed from each tube and antibody (IgM) production was detected by ELISA technique. The results of IgM production were higher in groups of 24 h, 48 h, 72 h and 7 days in relation to the other studied groups, with statistically significant differences (ANOVA and Tukey's test p < 0.05). Endotoxin was able to diffuse through the dentinal tubules towards the cement, reaching the external root surface after the period of 24 h.