131 resultados para Dinamic Stability in Power Systems
Resumo:
The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new procedure was developed in this study, based on a system equipped with a cellulose membrane and a tetraethylenepentamine hexaacetate chelator (MD-TEPHA) for in situ characterization of the lability of metal species in aquatic systems. To this end, the DM-TEPHA system was prepared by adding TEPHA chelator to cellulose bags pre-purified with 1.0 mol L-1 of HCl and NaOH solutions. After the MD-TEPHA system was sealed, it was examined in the laboratory to evaluate the influence of complexation time (0-24 h), pH (3.0, 4.0, 5.0, 6.0 and 7.0), metal ions (Cu, Cd, Fe, Mn and Ni) and concentration of organic matter (15, 30 and 60 mg L-1) on the relative lability of metal species by TEPHA chelator. The results showed that Fe and Cu metals were complexed more slowly by TEPHA chelator in the MD-TEPHA system than were Cd, Ni and Mn in all pH used. It was also found that the pH strongly influences the process of metal complexation by the MD-TEPHA system. At all the pH levels, Cd, Mn and Ni showed greater complexation with TEPHA chelator (recovery of about 95-75%) than did Cu and Fe metals. Time also affects the lability of metal species complexed by aquatic humic substances (AHS); while Cd, Ni and Mn showed a faster kinetics, reaching equilibrium after about 100 min, and Cu and Fe approached equilibrium after 400 min. Increasing the AHS concentration decreases the lability of metal species by shifting the equilibrium to AHS-metal complexes. Our results indicate that the system under study offers an interesting alternative that can be applied to in situ experiments for differentiation of labile and inert metal species in aquatic systems. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Solos submetidos ao mesmo sistema de manejo manifestam variabilidade espacial diferenciada de seus atributos. A variabilidade espacial da estabilidade de agregados foi caracterizada em um Latossolo Vermelho distrófico e Latossolo Vermelho eutroférrico, sob cultivo de cana-de-açúcar. Foram realizadas amostragens de terra nos pontos de interseção de uma malha de 10 x 10 linhas, espaçadas de 10 m, totalizando 100 pontos de amostragem por área, coletadas nas camadas de 0,0-0,2 e 0,2-0,4 m de profundidade, para determinação de diâmetro médio geométrico (DMG), diâmetro médio ponderado (DMP), agregados na classe >2,0 mm e teor de matéria orgânica do solo. O Latossolo Vermelho eutroférrico apresenta maior estabilidade de agregados quando comparado com o Latossolo Vermelho distrófico, condizente com o maior teor de argila, matéria orgânica e mineralogia gibbsítica. A evolução diferenciada dos Latossolos estudados explica os maiores alcances, o menor coeficiente de variação (CV) e a menor variabilidade, observados no Latossolo Vermelho eutroférrico para todos os atributos estudados.
Resumo:
This paper presents an efficient neural network for solving constrained nonlinear optimization problems. More specifically, a two-stage neural network architecture is developed and its internal parameters are computed using the valid-subspace technique. The main advantage of the developed network is that it treats optimization and constraint terms in different stages with no interference with each other. Moreover, the proposed approach does not require specification of penalty or weighting parameters for its initialization.
Resumo:
The concept of dynamized medicines is commonly used in homeopathy. As a medical practice, homeopathy is based on clinical observations and experimental assays. In spite of the lack of a credible scientific explanation for its action mechanisms, clinical evidence has been collected since 200 years ago. This paper discusses the most important physical models related to dynamized systems, as well as some perspectives and consequences in studying such systems. While early theories dealt with structural changes in single solvent molecules, modern theories consider collective effects and self-organizing properties. The concept of information was recently introduced to model the capability of a dynamized system to interact with a biological organism, without a molecular agent being needed. The features and limitations of theoretical approaches, as well as experimental results are discussed. (C) 2002 Published by Elsevier B.V. Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new procedure was developed for the in situ characterization of the lability of metal species in aquatic systems by using a system equipped with a diffusion membrane and cellulose organomodified with p-aminobenzoic acid groups (DM-Cell-PAB). To this end, the DM-Cell-PAB system was prepared by adding cellulose organomodified with p-aminobenzoic acid groups (Cell-PAB) to pre-purified cellulose bags. After the DM-Cell-PAB system was sealed, it was examined in the laboratory to evaluate the influence of complexation time, mass of exchanger, pH, metal ions (Cu, Cd, Fe, Mn, and Ni), and concentration of organic matter on the relative lability of metal species. It was found that the pH and kinetics strongly influence the process of metal complexation by the DM-Cell-PAB system. At all pH levels, Cd, Mn, and Ni showed lower complexation with Cell-PAB resin than Cu and Fe metals. Note that relative lability of metals complexed to aquatic humic substances (AHS) in the presence of Cell-PAB resin showed the following order: Cu congruent to Fe >> Ni > Mn=Cd. The results presented here also indicate that increasing the AHS concentration decreases the lability of metal species by shifting the equilibrium to AHS-metal complexes. Our results indicate that the system under study offers an interesting alternative that can be applied to in situ experiments for differentiation of labile and inert metal species in aquatic systems.
Resumo:
This paper deals with the design of a network-on-chip reconfigurable pseudorandom number generation unit that can map and execute meta-heuristic algorithms in hardware. The unit can be configured to implement one of the following five linear generator algorithms: a multiplicative congruential, a mixed congruential, a standard multiple recursive, a mixed multiple recursive, and a multiply-with-carry. The generation unit can be used both as a pseudorandom and a message passing-based server, which is able to produce pseudorandom numbers on demand, sending them to the network-on-chip blocks that originate the service request. The generator architecture has been mapped to a field programmable gate array, and showed that millions of numbers in 32-, 64-, 96-, or 128-bit formats can be produced in tens of milliseconds. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
We consider the Euclidean D-dimensional -lambda vertical bar phi vertical bar(4)+eta vertical bar rho vertical bar(6) (lambda,eta > 0) model with d (d <= D) compactified dimensions. Introducing temperature by means of the Ginzburg-Landau prescription in the mass term of the Hamiltonian, this model can be interpreted as describing a first-order phase transition for a system in a region of the D-dimensional space, limited by d pairs of parallel planes, orthogonal to the coordinates axis x(1), x(2),..., x(d). The planes in each pair are separated by distances L-1, L-2, ... , L-d. We obtain an expression for the transition temperature as a function of the size of the system, T-c({L-i}), i = 1, 2, ..., d. For D = 3 we particularize this formula, taking L-1 = L-2 = ... = L-d = L for the physically interesting cases d = 1 (a film), d = 2 (an infinitely long wire having a square cross-section), and for d = 3 (a cube). For completeness, the corresponding formulas for second-order transitions are also presented. Comparison with experimental data for superconducting films and wires shows qualitative agreement with our theoretical expressions.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Usually, the kinetic models used in the study of sintered ceramic are performed by means of indirect physical tests, such as, results obtained from data of linear shrinkage and mass loss. This fact is justified by the difficulty in the determinations of intrinsic parameters of ceramic materials along every sintering process. In this way, the technique of atomic force microscopy (AFM) was used in order to determine the importance and the evolution of the dihedral angle in the sintering of 0.5 mol% MnO2-doped tin dioxide obtained by the polymeric precursor method.