172 resultados para Conventional water treatment


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper aimed to study the treatability of rainwater collected in Rio Claro, SP, using natural coagulant tannin based. The tannin was compared with other too primary coagulants, namely ferric chloride and corn starch. Assays were performed in laboratory scale using equipment known as Jarteste and aimed to study the conditions most suitable dosage and coagulation pH. First tests were conducted to compare the coagulating and determination of the conditions to be used in the following tests, taking as a criterion the greatest efficiency for water treatment. Also performed were performed tests to construct the tannin coagulation diagram, using the optimal concentration found in the previous phase, by varying the dosage of coagulant and the pH of clotting in order to determine the isoefficiency regions for apparent color and turbidity. Finally, tests were performed cyclically filtration with filter paper. Preliminary tests indicated that the vegetable tannin concentration 3% (m/m) from the commercial solution was presented the best set of results (84.3% removal of apparent color and 82.51% removal of turbidity) compared to ferric chloride (66.25% removal efficiency and apparent color of turbidity 67.82%) and starch (73.68% removal efficiency apparent color and turbidity to 67.19%). The coagulation diagrams indicate that the best region to work with vegetable tannin 3% is where the coagulant dosage ranges from 15 mg/L to about 37.5 mg/L and coagulation pH ranging from about 6.5 to 7.5. The cyclic filtration showed to be not efficient for the best dosage of coagulant, due to the process of clogging of the filter paper, but proved to be efficient for other dosages. Thus, for the waters studied, the results indicate that the natural coagulant based tannin is an alternative to conventional coagulants, possessing benefits of technical and environmental

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have optimized an SPE-LC-ESI-MS/MS method and used it to monitor disperse azo dyes in environmental aquatic samples. Calibration curves constructed for nine disperse dyes-Red 1, Violet 93, Blue 373, Orange 1, Orange 3, Orange 25, Yellow 3, Yellow 7 and Red 13-in aqueous solution presented good linearity between 2.0 and 100.0 ng mL(-1). The method provided limits of detection and quantification around 2.0 and 8.0 ng L(-1), respectively. For dyes at concentrations of 25.0 ng mL(-1), the intra- and interday analyses afforded relative standard deviation lower than 6 and 13%, respectively. The recovery values obtained for each target analyte in Milli-Q water, receiving waters and treated water samples spiked with the nine studied dyes at concentrations of 8.0, 25.0 and 50.0 ng L(-1) (n = 3) gave average recoveries greater than 70%, with RSD <20%. Statistical evaluation aided method validation. The validated method proved to be useful for analysis of organic extracts from effluents and receiving water samples after an SPE extraction step. More specifically, the method enabled detection of the dyes Disperse Red 1, Disperse Blue 373 and Disperse Violet 93 at concentrations ranging from 84 to 3452 ng L(-1) in the treated effluent (TE), affluent and points collected upstream and downstream of the drinking water treatment plant of a textile dye industry in Brazil.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ultraviolet (UV) filters are widely used in the formulation of personal care products (PCPs) to prevent damage to the skin, lips, and hair caused by excessive UV radiation. Therefore, large amounts of these substances are released daily into the aquatic environment through either recreational activities or the release of domestic sewage. The concern regarding the presence of such substances in the environment and the exposure of aquatic organisms is based on their potential for bioaccumulation and their potential as endocrine disruptors. Although there are several reports regarding the occurrence and fate of UV filters in the aquatic environment, these compounds are still overlooked in tropical areas. In this study, we investigated the occurrence of the organic UV filters benzophenone-3 (BP-3), ethylhexyl salicylate (ES), ethylhexyl methoxycinnamate (EHMC), and octocrylene (OC) in six water treatment plants in various cities in Southeast Brazil over a period of 6 months to 1 year. All of the UV filters studied were detected at some time during the sampling period; however, only EHMC and BP-3 were found in quantifiable concentrations, ranging from 55 to 101 and 18 to 115 ng L(-1), respectively. Seasonal variation of BP-3 was most clearly noticed in the water treatment plant in Araraquara, São Paulo, where sampling was performed for 12 months. BP-3 was not quantifiable in winter but was quantifiable in summer. The levels of BP-3 were in the same range in raw, treated and chlorinated water, indicating that the compound was not removed by the water treatment process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A qualidade da água é muito importante para irrigação por gotejamento, pois ela escoa por pequenos bocais dos emissores, podendo ocorrer obstrução devido à deposição dos sólidos em suspensão. Portanto, antes da instalação do projeto, devem-se avaliar parâmetros de qualidade da água, para adotar medidas preventivas, evitando o risco de entupimento do sistema. Este trabalho teve como objetivo avaliar um sistema composto por aeradores com aspersores, sobre leito de pedra, para a precipitação dos íons Fe+2e Mn+2 em tanque de decantação, e um conjunto de filtragem composto por três filtros de areia e um de disco, em sistema de irrigação localizada. O trabalho foi realizado na Fazenda Alvorada, no município de Nova Granada - SP, no período de março a outubro de 2008. Foram realizadas determinações de variáveis físicas e químicas da água, ao longo do sistema de aeração, decantação e filtragem, o qual foi eficiente para a melhoria da qualidade de água, reduzindo os níveis de risco de entupimento de severo para médio e de médio para baixo. Oxigênio dissolvido, condutividade elétrica, pH, Fe+2e Fe+3 não diferenciaram a qualidade de água entre os pontos do sistema de tratamento, porém a turbidez, sólidos dissolvidos, sólidos em suspensão, ferro total e manganês total reduziram-se significativamente pelo uso do sistema proposto, melhorando a qualidade da água.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Verificar a qualidade higiênico-sanitária da água de consumo humano em propriedades rurais por meio da contagem de indicadores microbiológicos de potabilidade. MÉTODOS: Foram colhidas 180 amostras de água utilizada para consumo humano das fontes, reservatórios e ponto de consumo em 30 propriedades rurais, situadas na região Nordeste do Estado de São Paulo. Determinou-se o número mais provável de coliformes totais, Escherichia coli e o número de microrganismos mesófilos. Foi verificada a presença de medidas de proteção das fontes de abastecimento. RESULTADOS: Os resultados evidenciaram que 90% das amostras de água das fontes, 90% dos reservatórios e 96,7% de água de consumo humano, colhidas no período de chuvas, e 83,3%, 96,7% e 90%, daquelas colhidas respectivamente nos mesmos locais, durante a estiagem, estavam fora dos padrões microbiológicos de potabilidade para água de consumo humano. CONCLUSÕES: A água utilizada nas propriedades rurais foi considerada um importante fator de risco à saúde dos seres humanos que a utilizam. A adoção de medidas preventivas, visando à preservação das fontes de água, e o tratamento das águas já comprometidas são as ferramentas necessárias para diminuir consideravelmente o risco de ocorrência de enfermidades de veiculação hídrica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Slow sand filtration is an efficient water treatment technique used for treating surface water with relatively low levels of contamination. Despite the slow sand filtration at pathogen, algae and cyanobacteria removal efficiency, it has some restrictions in relation to the required area for slow filters, and the cleaning activities for the filters and the stone pre-filters when used in the treatment. This research evaluated during 120 days the use of non woven & sand pre-filtration columns as part of a slow filtration process for the apparent color, turbidity, algae, cyanobacteria, phytoflagellates and diatomaceous. The columns shown an efficient removal of the monitored parameters and demonstrated as a vantage their faster and easier cleaning process and less awkward than the required to the stone pre-filters. The turbidity removal efficiency increased progressively during the experiment, especially after the first 35 days of the start; the apparent color removal by the pre-filtration columns was of 85%, and working together with the polishing of activated carbon columns was up to 95; the diatomaceous, phytoflagellates, algae and cyanobacteria removal by the columns achieve a weekly average of 95%, its recommended to use filtration rates lower to 1,5m(3)/m(2)/d.