200 resultados para C18 bonded silica gel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An automated system with a C-18 bonded silica gel packed minicolumn is proposed for spectrophotometric detection of arsenic using flow-injection hydride generation following sorbent extraction preconcentration. Complexes formed between arsenic(III) and ammonium diethyl dithiophosphate (ADDP) are retained on a C-18 sorbent. The eluted As-DDP complexes are merged with a 1.5% (w/v) NaBH4 and the resulting solution is thereafter injected into the hydride generator/gas-liquid separator. The arsine generated is carried out by a stream of N-2 and trapped in an alkaline iodine solution in which the analyte is determined by the arsenomolybdenum blue method. With preconcentration time of 120 s, calibration in the 5.00-50.0 mu g As l(-1) range and sampling rate of about 20 samples h(-1) are achieved, corresponding to 36 mg ADDP plus 36 mg ammonium heptamolybdate plus 7 mg hydrazine sulfate plus 0.7 mg stannous chloride and about 7 mi sample consumed per determination. The detection limit is 0.06 mu g l(-1) and the relative standard deviation (n = 12) for a typical 17.0 mu g As l(-1) sample is ca. 6%. The accuracy was checked for arsenic determination in plant materials from the NIST (1572 citrus leaves; 1573 tomato leaves) and the results were in agreement with the certified values at 95% confidence level. Good recoveries (94-104%) of spiked tap waters, sugars and synthetic mixtures of trivalent and pentavalent arsenic were also found. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the attachment of 2-mercaptothiazoline (MTZ) to modified silica gel has been developed. In the first step, a new silylant agent was synthesized, named SiMTZ, by the reaction between MTZ molecule and chloropropyltrimethoxysilane (SiCl). SiMTZ and tetraethylortosilicate were co-condensed in the presence of n-dodecylamine, a neutral surfactant template, to produce a modified ordered hexagonal mesoporous silica named HMTZ. The modified material contained 0.89 +/- 0.03 mmol of 2-mercaptothiazoline per gram of silica. FT-IR, FT-Raman, Si-29- and C-13-NMR spectra were in agreement with the proposed structure of the modified mesoporous silica in the solid state. HMTZ material has been used for divalent mercury adsorption from aqueous solution at 298 I K. The series of adsorption isotherms were adjusted to a modified Langmuir equation. The maximum number of moles of mercury adsorbed gave 2.34 +/- 0.09 mmol/g of material. The same interaction was followed by calorimetric titration on an isoperibol calorimeter. The HMTZ presented a high capacity for the removal of the contaminant mercury from water. The Delta H and Delta G values for the interaction were determined to be -56.34 +/- 1.07 and -2.14 +/- 0.11 kJ mol(-1). This interaction process was accompanied by a decrease of entropy value (- 182 J mol(-1) K-1). Thus, the interaction between mercury and HMTZ resulted in a spontaneous thermodynamic system with a high favorable exothermic enthalpic effect. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The third generation (G-3) polypropylenimine hexadecaamine dendrimer (DAB-Am-16) was grafted onto the silica gel surface. The modified silica interacts easily with Cu(2+) and then with potassium ferrocyanide to form copper hexacyanoferrate. The modified silica was characterized by the following techniques: Nuclear Magnetic Resonance (NMR), FTIR spectroscopy, Energy Dispersive X-ray (EDX) and Cyclic Voltammetry. The modified silica containing copper hexacyanoferrate (CuHCFSD) was tested for a voltammetric determination of nitrite using a modified graphite paste electrode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silica gel chemically modified with 2-aminotiazole groups (SiAT), was used for preconcentration of cupper, zinc, nickel and iron from gasoline, normally used as a engine fuel. Surface characteristics and surface area of the silica gel were obtained before and after chemical modification using FT-IR, Kjeldhal and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques. The experimental parameters, such as shaking time in batch technique, flow rate and concentration of the eluent (HCl-0.25-2.00 mol 1(-1)) and the amount of silica, on retention and elution, have been investigated. Detection limits of the method for cupper, iron, nickel and zinc are 0.8, 3, 2 and 0.1 mug 1(-1), respectively. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in gasoline using flame AAS for their quantification. (C) 2004 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT) and the studies of adsorption and pre-concentration (in batch and using a flow-injection system coupled with optical emission spectrometer) of Cd(II), Cu(II) and Ni(II) in aqueous medium. The adsorption capacity for each metal ions in mmolg(-1) was: Cu(II) = 1.18, Ni(II) = 1.15 and Cd(II) = 1.10. The results obtained in the flow experiments showed about 100% of recovering of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 mu L of 2.0 mol L-1 HCl solution as eluent. The quantitative sorption-desorption of the metal ions made possible the application of a flow-injection system in the pre-concentration and quantification by ICP-OES of metal ions at trace level in natural water samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast, simple, non-destructive method for the direct screening of polycyclic aromatic hydrocarbons (PAHs) in vegetable oil samples is proposed. The method uses a supercritical fluid extraction (SFE) system coupled on-line with a fluorimetric detector to determine PAHs. This special assembly avoids the main problems encountered in the determination of PAHs in complex matrices such as vegetable oils. PAHs are selectively extracted by using silica gel in the thimble and cleaned up by passage through a C18 column. Interferences are preferentially retained by the silica gel during the SFE process while PAHs are adsorbed in the C18 column and the remainder of the matrix is sent to waste. Finally, the C18 column is purged to remove residual CO2 gas and adsorbed PAHs are recovered by desorption with a solvent. The extracts from positive samples are subsequently analyzed by liquid chromatography (LC) with fluorescence detection. The proposed method allows the confirmation of vegetable oil safety and hence provides a new tool for consumer protection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scanning electron microscopy (SEM) was used to investigated the effects of volatile solvents (such as water, propanone, ethanol, methanol or ethyl ether), treatment and drying processes, microwave ovens, drying ovens, and vacuum desiccators or freeze driers, on silica morphology. Silica gel was obtained from diluted sodium silicate (1:5 w/w SiO2:H2O). The results showed that the drying process based on freeze drying is more efficient for structural conservation of the precipitate. Treatment with volatile solvents does not change the shape of the aggregates, but has an important role in the determination of aggregate surface roughness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The brown alga Pilayella littoralis was used as a new biosorbent in an on-line metal preconcentration procedure in a flow-injection system. Al, Co, Cu and Fe were determined in lake water samples by inductively coupled plasma optical emission spectrometry (ICP-OES) after preconcentration in a silica-immobilized alga column. Like other algae, P. littoralis exhibited strong affinity for these metals proving to be an effective accumulation medium. Metals were bound at pH 5.5 and were displaced at pH < 2 with diluted HCl. The enrichment factors for Cu-II, Fe-III, Al-III and Co-II were 13, 7, 16 and 11, respectively. Metal sorption efficiency ranged from 86 to 90%. The method accuracy was assessed by using drinking water certified reference material and graphite furnace atomic absorption spectrometry (GFAAS) as a comparison technique. The column procedure allowed a less time consuming, easy regeneration of the biomaterial and rigidity of the alga provided by its immobilization on silica gel. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silica gel surface was chemically modified with beta-diketoamine groups by reacting the silanol from the silica surface with 3-aminopropyl-triethoxysilane and 3-bromopentanedione, With this material, copper ions were adsorbed from aqueous solutions, the chemical analysis of the silica-gel-immobilized acetylacetone provided a quantity of 0.67 mmol g(-1) of organic groups attached to the support and 0.63 mmol g(-1) of copper, This material was used as a stationary phase in IMAC (immobilized metal affinity chromatography), to separate alpha-lactoalbumin from bovine milk whey, the results showed an efficient separation in the chromatographic column, the possibility of reutilization of the stationary phase was also investigated. (C) 1997 Academic Press

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silica gel surface modified with imidazolylpropyl group was used to adsorb MX2 (M = Mn, Ni, Cu, Zn, and Cd; X = Cl, Br, and I) and FeCl3 from ethanol and acetone solution. The adsorption capacity and the intensity of the adsorption were determined by using the Langmuir equation. The influences of the solvent, temperature, and degree of functionalization on the adsorption were also studied. The infrared spectra of the functionalized silica were recorded between 1700-1300 cm-1. The bands of the imidazole skeletal vibrations are shifted to higher frequencies upon metal-to-base nitrogen interaction. © 1985.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Good optical quality Eu3+-doped silica-polyethyleneglycol hybrids were prepared by the sol-gel process. Thermomechanical analysis showed an increase of the glass transition temperature, due to the stiffness of the polymeric network, as the amount of Eu3+ increased. Europium luminescent properties were used to study structural evolution during the sol-gel transition. For lower doping concentrations dried gels present statistical distributions of Eu3+, typical of an amorphous environment, while for higher concentrations a crystalline-like environment of Eu3+ was observed. A broad emission band was observed in the visible part of the electromagnetic spectrum and assigned to the intrinsic emission from the hybrid polymeric network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The structural characteristics of saturated silica sonogels were studied by means of small-angle x-ray scattering (SAXS) and thermogravimetric analysis (TG), after a long time of aging in saturated conditions. The sonogels were obtained by a sol-gel routine from ultrasound stimulated tetramethoxysilane (TMOS) hydrolysis carried out with the initial water/TMOS molar ratio (r) ranging from 2 to 10. The saturated sonogel structure can be described as composed by mass fractal-like aggregates (clusters) of primary silica particles, all imbibed in a liquid phase. The values of the mass fractal dimension (D) of the clusters was found all around 2.5, while the characteristic size of the clusters (ξ) was found generally increasing with r, going from approximately 2.3 nm (r = 2) to 4.5 nm (r = 10). The volume fraction of the clusters was estimated from the SAXS data. The results were compared to the values of weight loss fraction at the inflection point that has been found in the derivative of the TG curve, which should accounts for the instant in which the meniscus of the liquid phase penetrates into the clusters under a rapid evaporation process as in a TG test.