660 resultados para Aspereza de superfície (Odontologia)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, RVC samples were treated by plasma immersion ion implantation (PIII) for electrodes production. High-voltage pulses with amplitudes of -3.0 kV or -10.0 kV were applied to the RVC samples while the treatment time was 10, 20 and 30 minutes. Nitrogen, atmospheric air and H2:N2 mixture were employed as plasma sources. The samples were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and electrochemical measurements. The SEM images present an apparent enhancement of the surface roughness after the treatment probably due to the surface sputtering during the PIII process. This observation is in agreement with the specific electrochemical surface area (SESA) of RVC electrodes. An increase was observed of the SESA values for the PIII treated samples compared to the untreated specimen. Some oxygen and nitrogen containing groups were introduced on the RVC surface after the PIII treatment. Both plasma-induced process: the surface roughening and the introduction of the polar species on the RVC surface are beneficial for the RVC electrodes application

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate in dental models the occlusal relationship of children treated or in orthodontic treatment of the Undergraduate Clinic of Araraquara Dental School – UNESP. It was analyzed the vertical, anteroposterior and transversal relationships of the casts models of 388 children by two previous calibrated examiners. The results were analyzed by descriptive statistics and it was found higher prevalence of occlusal deviations in the vertical direction, followed by the sagital dimension and in lower prevalence of the transverse direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the enamel wear permanent teeth after plastic stick or low speed rubber cup microabrasion. Ten permanent molars were selected to evaluate enamel wear which were sectioned into mesial and distal halves. Each half of the molars was randomly assigned to one of two experimental groups (n = 10) according to the enamel microabrasion technique: plastic stick (GE) or rubber cup (GT). In both the groups, the enamel was submitted to 10 applications of an abrasive paste comprised of 35% phosphoric acid and pumice powder. The paste was applied for 20 seconds under a pressure of 30 g using the instrument defined for each group (plastic stick or rubber cup). The specimens were evaluated under a stereomicroscope connected to a computer. The enamel wear no was statistically different between GE and GT, which presented a mean wear of 304.74 µm (21.20%) and 338.35 µm (22.75%). In conclusion, superficial enamel wear was seen for both the groups, independent of the technique used for the accomplishment of the microabrasion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enamel microabrasion is a non-invasive method that removes intrinsic and superficial defects from teeth aimed to improve dental esthetic with minimal loss of dental tissue. This case presentation describes the attempt for teeth color correction utilizing that conservative technique in a young girl whose upper central incisor presented an opaque white stain. Scanning electron microscopy (SEM) was conducted in order to illustrate the glasslike luster and a smooth texture of microabraded enamel surface. The correct diagnosis of defect is a difficult task, when consider this conservative approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the accuracy of the depth of carious lesions on bitewing radiographs. Methods Recently extracted primary molars had their proximal surfaces evaluated visually (EC) and classified as healthy surface (0), signs that suggest the presence of carious lesions in enamel (1), signs of a superficial lesion in dentin (2) and carious lesions in deep dentin (3). Results The results were obtained by consensus between the investigators. The gold standard was determined by histological analysis. The values of sensitivity, specificity, accuracy and area under the ROC (Receiver Operating Characteristic) curve were evaluated. There was equilibrium between sensitivity (76.92% EC and 88.46% ER) and specificity (95.83% EC and 95.83% ER). Accuracy was 86.01% (EC) and 88.46% (ER). The Spearman correlation test was used to prove the correlation between clinical and radiographic examinations (0.886), for clinical and histological (0.736) and for radiographic and histological analysis (0.843).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: pre-operative assessment is of fundamental importance for the prevention of transoperative and of postoperative complications. Objective: to identify the prevalence of diseases and systemic conditions in patients undergoing surgical treatment in the discipline of surgery and Traumatology of University Center of Araraquara, in the period of 2004 to 2009. Material and method: for the development of this study, a survey in medical records of patients was performed and the factors considered included: age, sex, presence of vices, and systemic conditions that affect the world’s population. The data obtained were analyzed quantitatively and recorded in a table. Result:  Considering all patient records analyzed (693), 340 affirmative responses were detected (49,06%) to one or more diseases. Cardiovascular diseases were the most prevalent (22,34%). Considering the prevalence of diseases related to age, the age of less than 20 years represented 16,32%; of 20-29 years, 43,06%; 30-39 years, 45,16%; 40-44 years, 48,64%; 45-49 years, 56,25%; 50-54 years, 58,33%; 55-59 years, 57,74%; 60-64 years, 70,37%; 65-69 years, 66,66%; and 70 years or more, 68,75%. Conclusion: diseases and systemic alterations with higher prevalence were cardiovascular diseases, anemia, sinusitis and diabetes. The frequency of affirmative answers to systemic conditions was age-dependent and there was a predominance of females. The tobacco addiction was the most frequent. Thus, it was found that the preoperative assessment of the health of patients who will undergo surgical dental treatment is of fundamental importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the morphology and adhesion of blood components on root surfaces instrumented with piezoelectric ultrasonic Piezon Master Surgery. Methods 10 teeth were used in this study. The teeth had their proximal divided into four areas that received different treatments: Group 1: untreated control Group 2: scaling with manual instrument; Group 3: scaling with ultrasound; Group 4: Scaling with manual instruments and ultrasound. We obtained 20 samples, 10 of which were used to analyze the morphology and the other 10 were used for analysis of adhesion of blood components. The specimens were analyzed by scanning electron microscopy. Photomicrographs were analyzed by the scores of adhesion of blood components and the index of root morphology. The results were statistically by the Kruskall-Wallis and Mann-Whitney with a significance level of 95%. Results The morphological analysis showed that the Group 1 had a surface unchanged in relation to other groups (Group 1 X Group 2 = 0.0025; Group 1 X Group 3 = 0.0003; Group 1 X Group 4 = 0.0003) and Group 2 presented a smoother surface compared to Group 1 and groups instrumented with ultrasound (Group 2 X Group 3 = 0.0025; Group 2 X Group 4 = 0.0025) there were no statistical differences between the Groups 3 and 4. analysis of adhesion of blood components showed that the Groups 2, 3 and 4 had no statistically significant differences between themselves, but more biocompatible surfaces promoted the surface untreated control (Group 1 X Group 2 = 0.02; Group 1 X Group 3 = 0.04; Group 1 X Group 4 = 0.005). Conclusion The instrumentation with piezoelectric ultrasonic promoted an irregular root surface, but did not negatively affect the adhesion of blood components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correction of bone defects is the restoration of lost structures which can be replaced by alloplastic implants or bone grafts. Due to the known disadvantages of removal of autogenous grafts, most researches in dentistry aim to develop alloplastic or non-alloplastic materials able to replace bone without these limitations. Beta-Tricalcium Phosphate (β-TCP) is a synthetic granular bone substitute, biocompatible, osteoconductive, which can be used in the alveolar reconstruction. In this work, we perform a literature review on the β-TCP characteristics and discuss its application in dentistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of bone grafts from bone tissue banks, also known as bone allografts, has increased in the last years, although most of its users still have concerns on resources and processing protocols. The objective of this paper was to make a literature review about the use of bone allografts in Dentistry, and also about the legal considerations regarding this biomaterial. Studies regarding the donor selection, the cross-infection risks and processing protocols of this biomaterial are still rare but essential, and allied to those regarding its clinical application, can base its use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success rate of resin-bonded fixed partial dentures is directly related to the adhesive system and the tooth preparation design for good retention. These resin-bonded bridges represent a prosthodontic alternative, based on their costeffectiveness, conservative techniques, and ease of laboratory manufacturing. Through a thorough review of the literature, this study aimed to report on cavity designs, types of materials used, and the advantages and disadvantages of the resin-bonded fixed partial denture. One of significant advantages of the resin-bonded fixed partial dentures is the conservation of the tooth structure, whereas its main disadvantage includes aesthetic limitations, given that the alloy may in fact be visible. Preparation design, cement type, and casting alloy type, as well as surface treatment, are among the factors that influence the longevity of resin-bonded fixed partial dentures. Treatments with resin-bonded fixed partial dentures present a bright outlook regarding the conservation of tooth structures, as well as a high level of success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the surface microhardness of compound resins cured by different light sources. Methods Three micro hybrid (Vit-l-escence, Amelogen Plus, Opallis) and one nanoparticle (Filtek Z350, 3M ESPETM Dental Products, St. Paul, USA) compound resins were selected. The resins were polymerized by a halogen light unit (Ultralux, Dabi Atlante, Ribeirão Preto, Brasil) with two tips, one semi-guided made of glass and another of painted acrylic and a LED-based source (UltraLume 2, Ultradent®, South Jordan, USA). Specimens constructed from a circular aluminum matrix were photopolymerized for 40 second after they received the compound resin and stored dry for 24 hours. After this period, a Vickers surface microhardness assay was performed, measuring the top (hardness 1) and base (hardness 2) surfaces four times each. Variance analyses were complemented by Newman-Keuls method, with significance set at 5%. Results The Opallis (FGM, Santa Catarina, Brasil) resin subjected to UltraLume 2 (Ultradent®, South Jordan, USA) obtained the lowest mean hardness values for the top surface. The Vit-l-escence (Ultradent®, South Jordan, USA) compound cured by Led UltraLume 2 (Ultradent®, South Jordan, USA) and by Ultralux PCP (Dabi Atlante, Ribeirão Preto, Brasil) halogen light obtained the highest mean hardness, followed by the Filtek Z350 (3M ESPETM Dental Products, St. Paul, USA) resin subjected to UltraLume 2 (Ultradent® South Jordan, USA). The Opallis (FGM, Santa Catarina, Brasil) resin cured by LED UltraLume 2 (Ultradent®, South Jordan, USA) also obtained the lowest mean hardness for the base surface and the Vit-L-Escence (Ultradent®, South Jordan, USA) resin obtained the highest value, followed by Amelogen Plus, when cured by Ultralux (Dabi Atlante, Ribeirão Preto, Brasil) using the semi-guided tip. Conclusion The polymerization and, consequently, the microhardness achieved by the LED unit was equivalent to those achieved by conventional halogen units for three of the four composites tested.