71 resultados para x radiation
Resumo:
Carboxyhaemoglobin-II isolated from the pacu (Piaractus mesopotamicus) has been crystallized and X-ray diffraction data were collected to 2.0 Angstrom resolution using synchrotron radiation. Crystals were characterized as belonging to the space group I23; preliminary structural analysis reveals the presence of one dimer in the asymmetric unit.
Resumo:
In the present work we consider a dynamical system of mum size particles around the Earth subject to the effects of radiation pressure. Our main goal is to study the evolution of its relative velocity with respect to the co-planar circular orbits that it crosses. The particles were initially in a circular geostationary orbit, and the particles size were in the range between 1 and 100 mum. The radiation pressure produces variations in its eccentricity, resulting in a change in its orbital velocity. The results indicated the maximum linear momentum and kinetic energy increases as the particle size increases. For a particle of 1 mum the kinetic energy is approximately 1.56 x 10(-7) J and the momentum is 6.27 x 10(-11) kg m/s and for 100 mum the energy is approximately 1.82 x 10(-4) J and the momentum is 2.14 x 10(-6) kg m/s. (C) 2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
Resumo:
Tuberculosis remains the leading cause of mortality arising from a bacterial pathogen ( Mycobacterium tuberculosis). There is an urgent need for the development of new antimycobacterial agents. The aromatic amino-acid pathway is essential for the survival of this pathogen and represents a target for structure-based drug design. Accordingly, the M. tuberculosis prephenate dehydratase has been cloned, expressed, purified and crystallized by the hanging-drop vapour-diffusion method using PEG 400 as a precipitant. The crystal belongs to the orthorhombic space group I222 or I2(1)2(1)2(1), with unit-cell parameters a = 98.26, b = 133.22, c = 225.01 angstrom, and contains four molecules in the asymmetric unit. A complete data set was collected to 3.2 angstrom resolution using a synchrotron-radiation source.
Resumo:
The hspA gene (XAC1151) from Xanthomonas axonopodis pv. citri encodes a protein of 158 amino acids that belongs to the small heat-shock protein ( sHSP) family of proteins. These proteins function as molecular chaperones by preventing protein aggregation. The protein was crystallized using the sitting-drop vapour-diffusion method in the presence of ammonium phosphate. X-ray diffraction data were collected to 1.65 angstrom resolution using a synchrotron-radiation source. The crystal belongs to the rhombohedral space group R3, with unit-cell parameters a = b = 128.7, c = 55.3 angstrom. The crystal structure was solved by molecular-replacement methods. Structure refinement is in progress.
Resumo:
Measurements of global and diffuse solar-radiation, at the Earth's surface, carried out from May 1994 to June 1999 in São Paulo City, Brazil, were used to develop correlation models to estimate hourly, daily and monthly values of diffuse solar-radiation on horizontal surfaces. The polynomials derived by linear regression fitting were able to model satisfactorily the daily and monthly values of diffuse radiation. The comparison with models derived for other places demonstrates some differences related mainly to altitude effects. (C) 2002 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Zhaoermiatoxin, an Arg49 phospholipase A(2) homologue from Zhaoermia mangshanensis (formerly Trimeresurus mangshanensis, Ermia mangshanensis) venom is a novel member of the PLA(2)-homologue family that possesses an arginine residue at position 49, probably arising from a secondary Lys49 -> Arg substitution that does not alter the catalytic inactivity towards phospholipids. Like other Lys49 PLA(2) homologues, zhaoermiatoxin induces oedema and strong myonecrosis without detectable PLA(2) catalytic activity. A single crystal with maximum dimensions of 0.2 x 0.2 x 0.5 mm was used for X-ray diffraction data collection to a resolution of 2.05 angstrom using synchrotron radiation and the diffraction pattern was indexed in the hexagonal space group P6(4), with unit-cell parameters a = 72.9, b = 72.9, c = 93.9 angstrom.
Resumo:
Pyroelectric sensors work as a thermal transducer converting the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. Ferroelectric ceramics and ferroelectric polymers have been extensively used as thermal detectors. More recently the research in the field of pyroelectricity has been concentrated on discovering materials with higher figures of merit (FOM), which means better sensing materials. Composite materials obtained with ferroelectric ceramics embedded in polymer host have received great attention because of their formability, mechanical resistance and the possibility to change their dielectric property varying the volume fraction of ceramic particles. In this work composite films made of modified lead titanate (PZ34) and poly(ether-ether-ketone) (PEEK) were characterized and used as sensing element to measure X-ray intensity in the ortovoltage range (120 - 300 kVp). The sensor response varies from 2.70 V to 0.80 V in the energy fluency range of 6.30 to 37.20 W/m(2). Furthermore the absorbed energy was analyzed as a function of the ionizing energy. The results indicate that the PZ34/PEEK composite with 60/40 vol.% can be useful to monitor X-ray radiation therapy.
Resumo:
The seed lectin from Lotus tetragonolobus (LTA) has been crystallized. The best crystals grew over several days and were obtained using the vapour-diffusion method at a constant temperature of 293 K. A complete structural data set was collected at 2.00 angstrom resolution using a synchrotron-radiation source. LTA crystals were found to be monoclinic, belonging to space group P2(1), with unit-cell parameters a = 68.89, b = 65.83, c = 102.53 angstrom, alpha = gamma = 90, beta = 92 degrees. Molecular replacement yielded a solution with a correlation coefficient and R factor of 34.4 and 51.6%, respectively. Preliminary analysis of the molecular-replacement solution indicates a new quaternary association in the LTA structure. Crystallographic refinement is under way.
Resumo:
Liposarcus anisitsi is an armoured catfish that presents accessorial air oxygenation through a modified stomach, which allows this species to survive in waters with very low oxygen content. Analysis of its haemolysate has shown the presence of four haemoglobins; this work focuses on the main component, haemoglobin I. It has been crystallized in two different forms and X-ray diffraction data have been collected to 2.77 and 2.86 Angstrom resolution using synchrotron radiation. Crystals were determined to belong to the space groups C2 and P2(1) and preliminary structural analysis revealed the presence of one tetramer in the asymmetric unit in both crystal forms. The structure was determined using a standard molecular-replacement technique.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work, initial crystallographic studies of human haemoglobin (Hb) crystallized in isoionic and oxygen-free PEG solution are presented. Under these conditions, functional measurements of the O-2-linked binding of water molecules and release of protons have evidenced that Hb assumes an unforeseen new allosteric conformation. The determination of the high-resolution structure of the crystal of human deoxy-Hb fully stripped of anions may provide a structural explanation for the role of anions in the allosteric properties of Hb and, particularly, for the influence of chloride on the Bohr effect, the mechanism by which Hb oxygen affinity is regulated by pH. X-ray diffraction data were collected to 1.87 Angstrom resolution using a synchrotron-radiation source. Crystals belong to the space group P2(1)2(1)2 and preliminary analysis revealed the presence of one tetramer in the asymmetric unit. The structure is currently being refined using maximum-likelihood protocols.
Resumo:
Haemoglobin, the 'honorary enzyme' [Brunori (1999), Trends Biochem. Sci. 24, 158-161], constitutes a prime prototype for allosteric models. Here, the crystallization and preliminary X-ray analysis of haemoglobin I from the South American fish Brycon cephalus are reported. X-ray diffraction data have been collected to 2.5 Angstrom resolution using synchrotron radiation (LNLS). Crystals were determined to belong to the space group P6(1)22 and preliminary structural analysis revealed the presence of one dimer (alpha beta) in the asymmetric unit. The structure was determined using standard molecular-replacement techniques.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The surface oxidation of UO2 sintered plates at 170-275 ° C was studied in situ by high temperature X-ray diffractometry. At very low oxygen concentration, UO2 is oxidized to U4O9, while at 300°C and argon-20 vol% oxygen it is oxidized up to U3O7. X-ray diffraction profiles of the UO2, U4O9 and U3O7 phases were well characterized during the transformations. The activation energy for the transformation of UO2 to U4O9, obtained from X-ray diffraction data, was found to be 117 ± 9 kJ/mol and 90 ± 14 kJ/mol for the β-(311) and α-(200) reflections, respectively. © 1991.
Resumo:
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.