60 resultados para strike-slip fault


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An apatite fission track study of crystalline rocks underlying sedimentary basins in northeastern Brazil indicate that crustal blocks that occur on opposite sides of a geological fault experienced different thermal histories. Samples collected on the West block yielded corrected fission-track ages from 140 to 375 Ma, whereas samples collected on the East block yielded ages between 90 and 125 Ma. The thermal models suggest that each block experienced two cooling events separated by a heating event at different times. We concluded that the West block moved downward relative to the East block ca. 140 Ma ago, when sediments eroded from the East side were deposited on the West side. This process represents the early stage of sedimentary basin formation and the opening of the South Atlantic Ocean in the region. Downward and upward movements related to heating and cooling events of these crustal blocks at different periods until recent times are proposed. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Precambrian crystalline basement of southeast Brazil is affected by many Phanerozoic reactivations of shear zones that developed during the end of the Neoproterozoic in the Brasiliano orogeny. These reactivations with specific tectonic events, a multidisciplinary study was done, involving geology, paleostress, and structural analysis of faults, associated with apatite fission track methods along the northeastern border of the Parana basin in southeast Brazil.The results show that the study area consists of three main tectonic domains, which record different episodes of uplift and reactivation of faults. These faults were brittle in character and resulted in multiple generations of fault products as pseudotachylytes and ultracataclasites, foliated cataclasites and fault gouges.Based on geological evidence and fission track data, an uplift of basement rocks and related tectonic subsidence with consequent deposition in the Parana basin were modeled.The reactivations of the basement record successive uplift events during the Phanerozoic dated via corrected fission track ages, at 387 +/- 50 Ma (Ordovician); 193 +/- 19 Ma (Triassic); 142 +/- 18 Ma (Jurassic), 126 +/- 11 Ma (Early Cretaceous); 89 +/- 10 Ma (Late Cretaceous) and 69 +/- 10 Ma (Late Cretaceous). These results indicate differential uplift of tectonic domains of basement units, probably related to Parana basin subsidence. Six major sedimentary units (supersequences) that have been deposited with their bounding unconformities, seem to have a close relationship with the orogenic events during the evolution of southwestern Gondwana. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single-phase superconducting fault current limiter (SFCL) using a 0.9 m length of YBCO coated conductor (CC) tape was tested in 220 V-60 Hz line for fault current up to 1 kA, operating in 77 K. In this work are presented the IN experimental curves measured under DC and AC currents for the electrical characterization of the CC tape in order to design a low voltage current limiter. The experimental setup is described and the test results are presented for a unit conducting a steady nominal AC current of 50 A and also during the fault time (I to 5 cycles.) the performance of the CC-based SFCL providing the limiting resistance developed in the whole tape length after few milliseconds of the beginning of the fault was analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new genus and species of cricket, Anomaloterga mantiqueirae, here described, is the first representative of Strogulomorphini to be reported from Brazil. The specimens were collected at night from the lower portions of live tree trunks in a summit forest located on the Mantiqueira Fault Escarpment, State of São Paulo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, an implementation of structural health monitoring process automation based on vibration measurements is proposed. The work presents an alternative approach which intent is to exploit the capability of model updating techniques associated to neural networks to be used in a process of automation of fault detection. The updating procedure supplies a reliable model which permits to simulate any damage condition in order to establish direct correlation between faults and deviation in the response of the model. The ability of the neural networks to recognize, at known signature, changes in the actual data of a model in real time are explored to investigate changes of the actual operation conditions of the system. The learning of the network is performed using a compressed spectrum signal created for each specific type of fault. Different fault conditions for a frame structure are evaluated using simulated data as well as measured experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sintering of SnO 2 compacts, obtained through slip casting, was studied by means of dilatometry, Hg porosimetry, scanning electron microscopy, and density measurement (Archimedes method). Sintering is strongly influenced by the green microstructure. Moreover, the sintering mechanisms are not dependent on the slurries' solid content up to 50% of solids in volume. Above this value, agglomerates are formed, leading to differential sintering inside and among the agglomerates. Another important point is the reduction of the temperature of maximum shrinkage rate when compared to tin oxide processed by isostatic pressing. This reduction is more accentuated when ammonium hydroxide is added to the suspension. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In engineering practical systems the excitation source is generally dependent on the system dynamic structure. In this paper we analyze a self-excited oscillating system due to dry friction which interacts with an energy source of limited power supply (non ideal problem). The mechanical system consists of an oscillating system sliding on a moving belt driven by a limited power supply. In the oscillating system considered here, dry friction acts as an excitation mechanism for stick-slip oscillations. The stick-slip chaotic oscillations are investigated because the knowledge of their dynamic characteristics is an important step in system design and control. Many engineering systems present stick-slip chaotic oscillations such as machine tools, oil well drillstrings, car brakes and others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phasor Measurement Units (PMUs) optimized allocation allows control, monitoring and accurate operation of electric power distribution systems, improving reliability and service quality. Good quality and considerable results are obtained for transmission systems using fault location techniques based on voltage measurements. Based on these techniques and performing PMUs optimized allocation it is possible to develop an electric power distribution system fault locator, which provides accurate results. The PMUs allocation problem presents combinatorial features related to devices number that can be allocated, and also probably places for allocation. Tabu search algorithm is the proposed technique to carry out PMUs allocation. This technique applied in a 141 buses real-life distribution urban feeder improved significantly the fault location results. © 2004 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot radial distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structures transverse/sub-transverse to the shoreline have been identified and characterized on the precambrian basement outcrop on the continent adjacent to the northern Santos Basin. These structures were analyzed from images of digital elevation model SRTM 90m by extracting NW-SE lineaments that intersect the NE-SW foliation. The lineaments were selected, classified into 48 segments that extend toward offshore, and correlated with basin structures. In the basin 25 2D seismic sections, 12 well logs and data from potential methods were interpreted, identifying the key stratigraphic levels and the major structures. Structural maps of each horizon were generated. Six transfer faults (FTs) were recognized and named FT-1 to FT-6, whose extensions correspond to continental lineaments named FC1 to FC6. The FTs are related to the basin deformation and evolution. In seismic sections, these faults have lateral slip in flower structures, displacement inversions from normal at the top to reverse at the base, abrupt changes in thickness or even disappearance of the seismic reflectors. The structural map of the Basement and Top of the Rift shows control of some depocenters by faults and displacements in some areas. The maps of potential methods indicate that there are pronounced anomaly shifts in some areas, associated with FTs. Some seismic sections indicate reactivation of FTs when they intersect horizons from the basement until the most recent layers. The 3D integration of data facilitated the observation of the FT extensions in the continent discontinuity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, one of the most important concerns for many companies is to maintain the operation of their systems without sudden equipment break down. Because of this, new techniques for fault detection and location in mechanical systems subject to dynamic loads have been developed. This paper studies of the influence of the decay rate in the design of state observers using LMI for fault detection in mechanical systems. This influence is analyzed by the performance index proposed by Huh and Stein for the condition of a state observer. An example is presented to illustrate the methodology discussed.