Resumo:

A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new genus and species of cricket, Anomaloterga mantiqueirae, here described, is the first representative of Strogulomorphini to be reported from Brazil. The specimens were collected at night from the lower portions of live tree trunks in a summit forest located on the Mantiqueira Fault Escarpment, State of São Paulo.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nowadays, one of the most important concerns for many companies is to maintain the operation of their systems without sudden equipment break down. Because of this, new techniques for fault detection and location in mechanical systems subject to dynamic loads have been developed. This paper studies of the influence of the decay rate in the design of state observers using LMI for fault detection in mechanical systems. This influence is analyzed by the performance index proposed by Huh and Stein for the condition of a state observer. An example is presented to illustrate the methodology discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL (xsuperconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level. © 2002-2011 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Far from the continental margin, drainage basins in Central Amazonia should be in topographic steady state; but they are not. Abandoned remnant fluvial valleys up to hundreds of square kilometers in size are observed throughout Amazonia, and are evidence of significant landscape reorganization. While major Late Miocene drainage shifts occurred due to initiation of the transcontinental Amazon River, local landscape change has remained active until today. Driven either by dynamic topography, tectonism, and/or climatic fluctuations, drainage captures in Amazonia provide a natural experiment for assessing the geomorphic response of low-slope basins to sudden, capture related base-level falls. This paper evaluates the timing of geomorphic change by examining a drainage capture event across the Baependi fault scarp involving the Cuieiras and TarumA-Mirim River basins northwest of the city of Manaus in Brazil. A system of capture-related knickpoints was generated by base-level fall following drainage capture; through numerical modeling of their initiation and propagation, the capture event is inferred to have occurred between the middle and late Pleistocene, consistent with other studies of landscape change in surrounding areas. In low-slope settings like the Amazon River basin, base-level fall can increase erosion rates by more than an order of magnitude, and moderate to large river basins can respond to episodes of base-level fall over timescales of tens to hundreds of thousands of years. Copyright (c) 2013 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Omega resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm(3). Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Resistive-type of superconducting fault current limiters (RSFCL) have been developed for medium voltage class aiming to operate at 1 MVA power capacity and short time recovery (< 2 s). A RSFCL in form of superconducting modular device was designed and constructed using 50 m-length of YBCO coated conductor tapes for operation under 1 kV / 1 kA and acting time of 0.1 s. In order to increase the acting time the RSFCL was combined with an air-core reactor in parallel to increase the fault limiting time up to 1 s. The tests determined the electrical and thermal characteristics of the combined resistive/ inductive protection unit. The combined fault current limiter reached a limiting current of 583 A, corresponding to a limiting factor of 3.3 times within an acting time of up to 1 s.